Patient safety issues in magnetic resonance imaging: state of the art

被引:32
|
作者
Stecco, A. [1 ]
Saponaro, A. [1 ]
Carriero, A. [1 ]
机构
[1] Univ Piemonte Orientale, ASO Maggiore Carita, SCDU Radiol, I-28100 Novara, Italy
来源
RADIOLOGIA MEDICA | 2007年 / 112卷 / 04期
关键词
MR; safety; foreing body; pacemaker; pregnancy;
D O I
10.1007/s11547-007-0154-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The presence of a static magnetic field (Bo), a radiofrequency field (RF), a dynamic gradient which varies in time and loud noises during an MR examination could increase patient risk. Specifically, a magnetic field could interfere with ferromagnetic material leading to one of the following five dangerous interactions: 1) projectile effect, 2) twisting, 3) burning, 4) artefacts and 5) device malfunction. The projectile effect is when an object is attracted by the magnet with the risk, as reported in literature, of hitting the patient, operators and/or the instrument. Objects which typically can undergo this effect are oxygen and helium cylinders, IV stands, cleaning trolleys, chairs, lamp holders, scissors, forceps, clampers, traction weights, monitoring instruments, and especially metallic splinters within the patient. Twisting (torsion) typically occurs with cerebral vascular clamps and cochlear implants. If parts of implants are involved a malfunction may result. Burns can be caused when electrically conductive material is introduced within the magnet, for example, ECG electrodes, monitoring cables and coils which are in contact with the patient's skin, as well as tattoos and eye-liners that contain iron-oxides. Artefacts can be induced by RF emission of implanted devices which can be mistaken for noise of the receiving coil. Implanted devices can induce signal voids which mask or simulate pathologies. Electrical or mechanical malfunction of implanted devices includes pacemakers which can stimulate inappropriately or at an elevated frequency yielding a distorted ECG with altered T-waves. The risk for patients can be reduced by specific educational programs within individual radiology departments which include other specializations and external referring physicians with the aim of developing a standardized safety protocol.
引用
收藏
页码:491 / 508
页数:18
相关论文
共 50 条
  • [1] Safety issues in magnetic resonance Imaging
    Chung, SM
    [J]. JOURNAL OF NEURO-OPHTHALMOLOGY, 2002, 22 (01) : 35 - 39
  • [2] State of the art in magnetic resonance imaging
    Jordan, David
    [J]. PHYSICS TODAY, 2020, 73 (02) : 34 - 40
  • [3] State of the art in magnetic resonance imaging
    Jordan, David
    [J]. Physics Today, 2020, 73 (02): : 34 - 40
  • [4] Patient safety in magnetic resonance imaging
    Rivas, R. Fraga
    Criado, J. de Miguel
    Lorente, L. Garcia del Salto
    Velasco, L. Gutierrez
    Valcarcel, P. Quintana
    [J]. RADIOLOGIA, 2023, 65 (05): : 447 - 457
  • [5] Magnetic Resonance Imaging: Fundamental Safety Issues
    Durbridge, Gail
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2011, 41 (11): : 820 - 828
  • [6] Patient safety issues in magnetic resonance imaging: state of the artLa safety del paziente in risonanza magnetica: stato dell’arte
    A. Stecco
    A. Saponaro
    A. Carriero
    [J]. La radiologia medica, 2007, 112 : 491 - 508
  • [7] Liver magnetic resonance imaging: State of the art
    Paul E Sijens
    [J]. World Journal of Gastroenterology, 2010, 16 (13) : 1558 - 1559
  • [8] The state of the art of fetal magnetic resonance imaging
    GUO Yuan and LUO Bo-ning Department of Radiology
    [J]. 中华医学杂志(英文版), 2006, (15) : 1294 - 1299
  • [9] Cardiovascular Magnetic Resonance Imaging: State of the Art
    Voros, Szilard
    Kramer, Christopher M.
    [J]. CURRENT CARDIOLOGY REVIEWS, 2005, 1 (03) : 181 - 188
  • [10] The state of the art of fetal magnetic resonance imaging
    GUO Yuan and LUO Boning Department of Radiology First Affiliated Hospital of Sun Yatsen University Guangzhou China
    [J]. Chinese Medical Journal, 2006, (15) : 1294 - 1299