Effects of sample injection amount and time-of-flight mass spectrometric detection dynamic range on metabolome analysis by high-performance chemical isotope labeling LC-MS

被引:18
|
作者
Zhou, Ruokun [1 ]
Li, Liang [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Dynamic range of detection; Isotope labeling; LC-MS; TOF-MS; Metabolite; Metabolomics; BIOLOGICAL SAMPLES;
D O I
10.1016/j.jprot.2014.08.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of sample injection amount on metabolome analysis in a chemical isotope labeling (CIL) liquid chromatography-mass spectrometry (LC-MS) platform was investigated. The performance of time-of-flight (TOE) mass spectrometers with and without a high-dynamic-range (HD) detection system was compared in the analysis of C-12(2)/C-13(2)-dansyl labeled human urine samples. An average of 1635 +/- 21 (n = 3) peak pairs or putative metabolites was detected using the HD-TOF-MS, compared to 1429 +/- 37 peak pairs from a conventional or non-HD TOF-MS. In both instruments, signal saturation was observed. However, in the HD-TOF-MS, signal saturation was mainly caused by the ionization process, while in the non-HD TOF-MS, it was caused by the detection process. To extend the MS detection range in the non-HD TOF-MS, an automated switching from using C-12 to C-13-natural abundance peaks for peak ratio calculation when the C-12 peaks are saturated has been implemented in IsoMS, a software tool for processing CIL LC-MS data. This work illustrates that injecting an optimal sample amount is important to maximize the metabolome coverage while avoiding the sample carryover problem often associated with over-injection. A TOP mass spectrometer with an enhanced detection dynamic range can also significantly increase the number of peak pairs detected. Biological significance In chemical isotope labeling (CIL) LC-MS, relative metabolite quantification is done by measuring the peak ratio of a C-13(2)-/C-12(2)-labeled peak pair for a given metabolite present in two comparative samples. The dynamic range of peak ratio measurement does not need to be very large, as only subtle changes of metabolite concentrations are encountered in most metabolomic studies where relative metabolome quantification of different groups of samples is performed. However, the absolute concentrations of different metabolites can be very different, requiring a technique to provide a wide detection dynamic range to allow the detection of as many peak pairs as possible. In this work, we demonstrated that controlling the sample injection amount into LC-MS was critical to achieve the optimal detectability while avoiding sample carry-over problem. In addition, the use of a high-dynamic-range dTOF system increased the number of peak pairs detected, compared to a conventional TOF system. We also investigated the ionization and detection saturation factors limiting the dynamic range of detection. This article is part of a Special Issue entitled: Protein dynamics in health and disease. Guest Editors: Pierre Thibault and Anne-Claude Gingras. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 139
页数:10
相关论文
共 37 条
  • [1] Instrument-type effects on chemical isotope labeling LC-MS metabolome analysis: Quadrupole time-of-flight MS vs. Orbitrap MS
    Wang, Chu -Fan
    Li, Liang
    [J]. ANALYTICA CHIMICA ACTA, 2022, 1226
  • [2] Development of High-Performance Chemical Isotope Labeling LC-MS for Profiling the Human Fecal Metabolome
    Xu, Wei
    Chen, Deying
    Wang, Nan
    Zhang, Ting
    Zhou, Ruokun
    Huan, Tao
    Lu, Yingfeng
    Su, Xiaoling
    Xie, Qing
    Li, Liang
    Li, Lanjuan
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (02) : 829 - 836
  • [3] Nanoflow LC-MS for High-Performance Chemical Isotope Labeling Quantitative Metabolomics
    Li, Zhendong
    Tatlay, Jaspaul
    Li, Liang
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (22) : 11468 - 11474
  • [4] Development of High-Performance Chemical Isotope Labeling LC-MS for Profiling the Carbonyl Submetabolome
    Zhao, Shuang
    Dawe, Margot
    Guo, Kevin
    Li, Liang
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (12) : 6758 - 6765
  • [5] Comprehensive and Quantitative Profiling of the Human Sweat Submetabolome Using High-Performance Chemical Isotope Labeling LC-MS
    Hooton, Kevin
    Han, Wei
    Li, Liang
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (14) : 7378 - 7386
  • [6] High tolerance to instrument drifts by differential chemical isotope labeling LC-MS: A case study of the effect of LC leak in long-term sample runs on quantitative metabolome analysis
    Chen, Deying
    Zhao, Shuang
    Han, Wei
    Lo, Elvis
    Su, Xiaoling
    Li, Liang
    Li, Lanjuan
    [J]. JOURNAL OF MASS SPECTROMETRY, 2021, 56 (04):
  • [7] Simultaneous determination of metacavir and its metabolites in rat plasma using high-performance liquid chromatography with tandem mass spectrometric detection (LC-MS/MS)
    Zhang, Yue
    Huang, Xin
    Jiang, Zhenzhou
    Huang, Xiao
    Hu, Yue
    Zhu, Dan
    Zhang, Shuang
    Wang, Jiaying
    Zhang, Luyong
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (03) : 363 - 370
  • [8] Development of a High-Coverage Quantitative Metabolome Analysis Method Using Four-Channel Chemical Isotope Labeling LC-MS for Analyzing High-Salt Fermented Food
    Li, Zhihua
    Dong, Ling
    Zhao, Chi
    Zhang, Fengju
    Zhao, Shuang
    Zhan, Jingjing
    Li, Jia
    Li, Liang
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2022, 70 (28) : 8827 - 8837
  • [9] Separation and characterization of oligomeric hindered amine light stabilizers using high-performance liquid chromatography with UV and quadrupole time-of-flight mass spectrometric detection
    Hintersteiner, Ingrid
    Reisinger, Michael
    Himmelsbach, Markus
    Buchberger, Wolfgang
    [J]. JOURNAL OF SEPARATION SCIENCE, 2016, 39 (06) : 1056 - 1066
  • [10] Simultaneous high-performance liquid chromatography with diode array detection and time-of-flight mass spectrometric confirmation of the ten bioactive compounds in Semen Sojae Preparatum
    Qiu, Feng
    Shi, Linyi
    Wang, Siqi
    Wu, Sha
    Wang, Manyuan
    [J]. JOURNAL OF SEPARATION SCIENCE, 2018, 41 (17) : 3360 - 3371