Calcium scoring of aortic valve calcification in aortic valve stenosis with a multislice computed tomography scanner:: Non-enhanced versus contrast-enhanced studies

被引:13
|
作者
Mühlenbruch, G
Wildberger, JE
Koos, R
Das, A
Thomas, C
Ruhl, K
Niethammer, M
Floh, TG
Stanzel, S
Günther, RW
Mahnken, AH
机构
[1] Univ Hosp RWTH Aachen, Dept Diagnost Radiol, Dept Cardiol, Inst Med Stat, D-52057 Aachen, Germany
[2] Siemens Med Solut, Computed Tomog, Forchheim, Germany
关键词
aortic valve calcification; aortic valve stenosis; calcium scoring; contrast material; multislice CT (MSCT);
D O I
10.1080/02841850510021698
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Previous studies have shown a positive correlation between amount of aortic valve calcification (AVC) and degree of aortic valve stenosis (AVS). We have investigated whether calcium scoring of AVC from contrast-enhanced images is reliable. Material and Methods: Nineteen patients with suspected AVS underwent retrospectively ECG-gated multislice computed tomography (MSCT). Standardized scan protocols were applied prior to (120 KV, 133 mAseff) and after (120 KV, 500 mAseff) the administration of non-ionic contrast material. Image reconstruction was performed at 60% of the RR interval (slice thickness 3 mm, reconstruction increment 2 mm). AVC was quantified using Agatston score and calcium mass. The number of lesions was calculated. All non-enhanced images were scored using thresholds of 130 HU and 350 HU. Contrast-enhanced images were assessed with a threshold of 350 HU exclusively. Results: Fifteen patients with AVCs were included in the statistical analysis. The mean Agatston score (calcium mass) in non-enhanced images was 2888.4 +/- 2844.4 (694.2 mg +/- 869.3 mg). Altering the threshold from 130 HU to 350 HU led to a 58.2% (30.5%) decrease in the AVC score (P values <0.001). Contrast-enhanced images showed an increased Agatston score (calcium mass) of 56.2% (33.5%) compared to non-enhanced images (P values <0.05) with the same threshold of 350 HU. Conclusion: Quantification of AVC from contrast-enhanced images is not reliable, as contrast material simulates calcification.
引用
收藏
页码:561 / 566
页数:6
相关论文
共 50 条
  • [1] Quantification of Aortic Valve Calcification in Contrast-Enhanced Computed Tomography
    Laohachewin, Danai
    Ruile, Philipp
    Breitbart, Philipp
    Minners, Jan
    Jander, Nikolaus
    Soschynski, Martin
    Schlett, Christopher L.
    Neumann, Franz-Josef
    Westermann, Dirk
    Hein, Manuel
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [2] ASSESSMENT OF AORTIC VALVE CALCIFICATION USING CONTRAST-ENHANCED COMPUTED TOMOGRAPHY
    Parks, Matthew
    Cartlidge, Timothy
    [J]. HEART, 2017, 103 : A3 - A3
  • [3] Photon Counting Computed Tomography for Aortic Valve Calcium Scoring in Contrast-Enhanced Datasets of the Heart
    Harmel, Eva K.
    Braun, Franziska
    Rippel, Katharina
    Scheurig-Muenkler, Christian
    Kroencke, Thomas
    Girdauskas, Evaldas
    von Scheidt, Wolfgang
    Schwarz, Florian
    [J]. CIRCULATION, 2021, 144
  • [4] FIBROCALCIFIC VOLUME IN AORTIC VALVE STENOSIS USING CONTRAST-ENHANCED COMPUTED TOMOGRAPHY
    Joshi, Shruti
    Lembo, Maria
    Bing, Rong
    Carnevale, Lorenzo
    Tzolos, Evangelos
    Pawade, Tania A.
    Doris, Mhairi K.
    Dey, Damini
    Newby, David E.
    Dweck, Marc R.
    [J]. HEART, 2022, 108 : A106 - A108
  • [5] Computed Tomography Aortic Valve Calcium Scoring in Patients With Bicuspid Aortic Valve Stenosis
    Shen, Mylene
    Oh, Jin Kyung
    Guzzetti, Ezequiel
    Singh, Gurpreet K.
    Pawade, Tania
    Tastet, Lionel
    Clavel, Marie-Annick
    Delgado, Victoria
    Bax, Jeroen J.
    Dweck, Marc R.
    Abbas, Amr E.
    Mando, Ramy
    Luis Falconi, Mariano
    Perez de Arenaza, Diego
    Poh, Kian Keong
    Kong, William
    Tay, Edgar
    Pressman, Gregg
    Brito, Daniel
    Song, Jae Kwan
    Pibarot, Philippe
    [J]. STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2022, 6 (01):
  • [6] Sex difference in aortic valve fibrosis assessed by contrast-enhanced computed tomography in severe aortic stenosis
    Myasoedova, V.
    Fraschini, E.
    Mostardini, G.
    Bonfanti, L.
    Chiesa, M.
    De Pasquale, C.
    Olivares, P.
    Trabattoni, D.
    Bartorelli, A. L.
    Andreini, D.
    Poggio, P.
    [J]. EUROPEAN HEART JOURNAL, 2021, 42 : 1618 - 1618
  • [7] Computed Tomography Aortic Valve Calcium Scoring in Patients With Aortic Stenosis
    Pawade, Tania
    Clavel, Marie-Annick
    Tribouilloy, Christophe
    Dreyfus, Julien
    Mathieu, Tiffany
    Tastet, Lionel
    Renard, Cedric
    Gun, Mesut
    Jenkins, William Steven Arthur
    Macron, Laurent
    Sechrist, Jacob W.
    Lacomis, Joan M.
    Nguyen, Virginia
    Gay, Laura Galian
    Calabria, Hug Cuellar
    Ntalas, Ioannis
    Cartlidge, Timothy Robert Graham
    Prendergast, Bernard
    Rajani, Ronak
    Evangelista, Arturo
    Cavalcante, Joao L.
    Newby, David E.
    Pibarot, Philippe
    Zeitoun, David Messika
    Dweck, Marc R.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (03)
  • [8] Photon Counting Computed Tomography for Aortic Valve Calcium Scoring in Contrast Enhanced Datasets of the Heart
    Harmel, Eva K.
    Braun, Franziska
    Risch, Franka
    Rippel, Katharina
    Scheurig, Christian
    Owais, Tamer
    Elvinger, Sebastien
    Girdauskas, Evaldas
    Kroencke, Thomas
    Raake, Philip W.
    Schwarz, Florian
    [J]. CIRCULATION, 2022, 146
  • [9] AORTIC VALVE CALCIUM QUANTIFICATION USING CONTRAST ENHANCED COMPUTED TOMOGRAPHY
    Shotwell, Matthew K.
    Sankaramangalam, Kesavan
    Potluri, Saipriya
    Zeb, Irfan
    Brito, Daniel
    Kadiyala, Madhavi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1242 - 1242
  • [10] PSEUDO DOUBLE AORTIC VALVE MISSED BY CONTRAST-ENHANCED COMPUTED TOMOGRAPHY
    Clark, Brad
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 2253 - 2253