A novel anaerobic filter membrane bioreactor: prototype start-up and filtration assays

被引:5
|
作者
Diez, V [1 ]
Iglesias, A. [1 ]
Camara, J. M. [2 ]
Ruiz, M. O. [1 ]
Ramos, C. [1 ]
机构
[1] Univ Burgos, Dept Biotechnol & Food Sci, Chem Engn Div, Plaza Misael Banuelos, Burgos 09001, Spain
[2] Univ Burgos, Dept Electromech Engn, Elect Technol Div, Avda Cantabria S-N, Burgos 09006, Spain
关键词
anaerobic filter; anaerobic filter membrane bioreactor; anaerobic membrane bioreactors; gas-lift; WASTEWATERS; PERFORMANCE; DIGESTION; SYSTEMS; DESIGN; DAIRY; FLUX;
D O I
10.2166/wst.2018.309
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Anaerobic digestion allows efficient treatment of high loaded wastewater, and membrane technology allows obtaining high quality effluents with complete biomass retention. However, high biomass concentration interferes with membrane fouling. In the present work, a new bioreactor that integrates an attached biomass anaerobic culture on a fixed bed and a submerged membrane has been started up. The recirculation between the digestion and filtration chambers is coupled to the gas-lift effect of the bubbling employed for the scouring of the membranes, avoiding the use or electromechanical pumps that damage the suspended biomass. The support material retains the biomass in the digestion tank despite the downwards flow, avoiding the submerged membrane contacting with a high concentrated suspension. This novel system, called an anaerobic filter membrane bioreactor was immediately started up, achieving chemical oxygen demand (COD) removal efficiencies of 96% at an organic loading rate (OLR) of 7 kg COD/m(3).d. In order to select filtration flux, specific gas demand and filtration cycle duration, the results of 15 short term assays, eight hours for each one, is presented for fluxes between 15.7 and 17.7 L/m(2).h, cycle duration between 10 and 30 minutes, and three levels of scouring. It was checked that reversible and irreversible fouling were directly related when dTMP/dt > 2.5 mbar/min.
引用
收藏
页码:1833 / 1842
页数:10
相关论文
共 50 条
  • [1] Start-up of anaerobic ammonium oxidation process in an upflow blanket filter bioreactor
    Wu, Li-Bo
    Gong, Yue
    Long, Bin
    He, Shi-Zhong
    Peng, Xin-Hong
    Jiang, Jun
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2008, 41 (11): : 1367 - 1371
  • [2] Characteristics of start-up of anaerobic bioreactor for PCP degradation
    Zhejiang Agricultural Univ, Hangzhou, China
    Taiyangneng Xuebao, 4 (408-416):
  • [3] Start-up of the Anammox process in a membrane bioreactor
    Trigo, C.
    Campos, J. L.
    Garrido, J. M.
    Mendez, R.
    JOURNAL OF BIOTECHNOLOGY, 2006, 126 (04) : 475 - 487
  • [4] BIOMASS ACCLIMATISATION AND ADAPTATION DURING START-UP OF A SUBMERGED ANAEROBIC MEMBRANE BIOREACTOR (SAMBR)
    Akram, A.
    Stuckey, D. C.
    ENVIRONMENTAL TECHNOLOGY, 2008, 29 (10) : 1053 - 1065
  • [5] Start-up of the anammox process and membrane fouling analysis in a novel rotating membrane bioreactor
    Jiang, Tao
    Zhang, Hanmin
    Qiang, Hong
    Yang, Fenglin
    Xu, Xiaochen
    Du, Hai
    DESALINATION, 2013, 311 : 46 - 53
  • [6] Start-up of pilot-scale anaerobic bioreactor landfill
    Department of Environmental Science and Engineering, Tsinghua University, Beijing 100084, China
    不详
    Zhongguo Huanjing Kexue, 2007, 2 (145-149): : 145 - 149
  • [7] Start-up of anaerobic ammonia oxidation bioreactor with nitrifying activated sludge
    ZHENG Ping *1
    3. Gongshu Division of Hangzhou Environmental Protection Bureau
    Journal of Environmental Sciences, 2004, (01) : 13 - 16
  • [8] Start-up of anaerobic ammonia oxidation bioreactor with nitrifying activated sludge
    Zheng, P
    Lin, FM
    Hu, BL
    Chen, JS
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2004, 16 (01) : 13 - 16
  • [9] Influence of Temperature on the Start-up of Membrane Bioreactor: Kinetic Study
    Leyva-Diaz, J. C.
    Martin-Pascual, J.
    Calero-Diaz, G.
    Torres, J. C.
    Poyatos, J. M.
    FRONTIERS IN WASTEWATER TREATMENT AND MODELLING, FICWTM 2017, 2017, 4 : 165 - 171
  • [10] Influence of temperature on the start-up of membrane bioreactor: kinetic study
    Leyva-Diaz, J. C.
    Martin-Pascual, J.
    Calero-Diaz, G.
    Torres, J. C.
    Poyatos, J. M.
    WATER SCIENCE AND TECHNOLOGY, 2018, 77 (02) : 448 - 455