CFRP-to-concrete bond behavior under aggressive exposure of sewer chamber

被引:8
|
作者
Mohammadi, Mahdie [1 ]
Mostofinejad, Davood [2 ]
机构
[1] Sepahan Inst Sci & Technol Higher Educ, Dept Civil Engn, Esfahan, Iran
[2] Isfahan Univ Technol IUT, Dept Civil Engn, Esfahan, Iran
关键词
EBR; EBROG; aggressive exposure; FRP; durability; bond behavior; FREEZE-THAW CYCLES; EBROG METHODS; FRP SHEETS; STRENGTH; PERFORMANCE; DURABILITY;
D O I
10.1177/00219983211004699
中图分类号
TB33 [复合材料];
学科分类号
摘要
The growing industrialization over the past century has led to increased exposure of structures to such aggressive conditions as found in sewer networks. The rehabilitation and maintenance of sewer systems call for innovative wastewater collection systems based on their design life cycle and operational conditions. Acid exposure is one such condition whose impacts on sewer systems strengthened with FRP sheets still await adequate research. The present paper reports the results of a study conducted in an aggressive concrete sewer chamber in an industrial zone, chosen as an outdoor test design to investigate the effects of an acid environment on the bond strength of FRP sheets bonded on the concrete surface via either of the two techniques of externally bonded reinforcement (EBR) or externally bonded reinforcement on grooves (EBROG). The results show that the bond strength of the EBR specimens depends on both exposure type and duration while the aggressive environment has no significant effects on the bond strength of EBROG specimens. Generally, maximum bond strength in EBR specimens decreases by up to about 19.7% with increasing exposure duration to 6000 h. In the case of EBROG specimens, however, maximum bond strength initially increases by 8.9% after 3000 h of exposure before it declines by 3.6% after 6000 h.
引用
收藏
页码:3359 / 3373
页数:15
相关论文
共 50 条
  • [1] Influence of long-term outdoor exposure in a frigid zone on the CFRP-to-concrete bond behavior
    Pan, Yunfeng
    Xian, Guijun
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 215 : 462 - 474
  • [2] Anchorages Effects on CFRP-to-concrete Bond Strength
    Anil, Oezguer
    Belgin, Cagatay M.
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2010, 29 (04) : 539 - 557
  • [3] Experimental and Analytical Study of Bond Stress-Slip Behavior at the CFRP-to-Concrete Interface
    Fathi, Abbas
    El-Saikaly, Georges
    Chaallal, Omar
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2023, 27 (02)
  • [4] Effect of end anchorage on bond behavior of CFRP-to-concrete interface subjected to temperature variation
    Hao J.
    Dong K.
    Jiang J.
    Yang S.
    Du D.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2021, 53 (04): : 62 - 70
  • [5] Experimental Study on Dynamic Behavior of CFRP-to-Concrete Interface
    Huo, Jingsi
    Liu, Jingya
    Dai, Xiaoqing
    Yang, Jin
    Lu, Yuan
    Xiao, Yan
    Monti, Giorgio
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (05)
  • [6] The bond behaviour of CFRP-to-concrete bonded joints under fatigue cyclic loading: An experimental study
    Zhou, Hao
    Fernando, Dilum
    Van Thuan Nguyen
    Dai, Jian-Guo
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 273
  • [7] Effects of long-term exposure of NSM CFRP-to-concrete bond to natural and accelerated aging environments
    Dushimimana, Aloys
    Sena-Cruz, Jose
    Correia, Luis
    Pereira, Joa Miguel
    Cabral-Fonseca, Susana
    Cruz, Ricardo
    COMPOSITE STRUCTURES, 2024, 340
  • [8] The bond-behaviour of CFRP-to-concrete bonded joints under fatigue loading: A damage accumulation model
    Zhou, Hao
    Zhang, S. S.
    Fernando, Dilum
    Huang, Tianli
    ENGINEERING FRACTURE MECHANICS, 2023, 284
  • [9] Development of bond strength model for CFRP-to-concrete joints at high temperatures
    Dong, Kun
    Hu, Kexu
    COMPOSITES PART B-ENGINEERING, 2016, 95 : 264 - 271
  • [10] Investigating the effect of steel fiber content on bond behavior between externally bonded CFRP-to-concrete joints
    Mensah, Comfort
    Min, Benzhi
    Wang, Zhenqing
    Bonsu, Alex Osei
    STRUCTURES, 2022, 36 : 565 - 579