A new measuring method for the forced vital capacity of individual lung lobes using multidetector-row CT

被引:0
|
作者
Ohkawa, T [1 ]
Kobashi, S [1 ]
Nakano, K [1 ]
Kondo, K [1 ]
Hata, Y [1 ]
Date, H [1 ]
机构
[1] Himeji Inst Technol, Grad Sch Engn, Himeji, Hyogo 67122, Japan
关键词
forced vital capacity; lung lobe; living-donor lobar lung transplantation; Multidetector-row CT. spirometry;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Forced vital capacity (FVC) of individual lung lobes is important information for thoracic surgeries such as the living-donor lobar lung transplantation. However conventional methods for measuring the FVC of individual lung lobes have not considered the variation of the lobar function among subjects. This paper proposes a new method for measuring the FVC of individual lung lobes using, Multidefector-row CT. The method first estimates contribution ratios of individual lung lobes for the FVC of whole lung. Using the estimated contribution ratios and the FVC of whole lung measured by a spirometry, our method estimates the FVC of individual lung lobes. As a result of applying the proposed method to live normal subjects, we could successfully measure the FVC of individual lung lobes.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 50 条
  • [1] Multidetector-row CT of lung cancer screening
    Jacobson, FL
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 168 - 175
  • [2] Classification of lung area using multidetector-row CT images
    Mukaibo, T
    Kawata, Y
    Niki, N
    Ohmatsu, H
    Kakinuma, R
    Kaneko, M
    Eguchi, K
    Moriyama, N
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1292 - 1300
  • [3] Multidetector-row CT and interstitial lung disease
    Hunsaker, AR
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 176 - 185
  • [4] Multidetector-row CT image quality and radiation dose: Imaging the lung
    Judy, PF
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 186 - 192
  • [5] Effective radiation dose for lung cancer screening with multidetector-row CT
    Herzog, P
    Schoepf, JU
    Becker, CR
    Rogallu, P
    Bitterling, H
    Henschke, C
    Relser, M
    RADIOLOGY, 2002, 222 (02) : 589 - 590
  • [6] DMechanism of Hypoxemia in acute lung injury evaluated by multidetector-row CT
    Easley, RB
    Fuld, MK
    Fernandez-Bustamante, A
    Hoffman, EA
    Simon, BA
    ACADEMIC RADIOLOGY, 2006, 13 (07) : 916 - 921
  • [7] Intracranial haemorrhage studied by using multidetector-row CT angiography
    Saba, L.
    Mallarini, G.
    EUROPEAN JOURNAL OF NEUROLOGY, 2008, 15 : 264 - 264
  • [8] LUNG LOBAR SEGMENTATION USING TUBULAR TISSUE DENSITY FROM MULTIDETECTOR-ROW CT IMAGES
    Kobashi, Syoji
    Hata, Yutaka
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2010, 6 (3A): : 829 - 842
  • [9] Advantages of multidetector-row CT with multiplanar reformation in guiding percutaneous lung biopsies
    De Filippo, M.
    Onniboni, M.
    Rusca, M.
    Carbognani, P.
    Ferrari, L.
    Guazzi, A.
    Casalini, A.
    Verardo, E.
    Cataldi, V.
    Tiseo, M.
    Sverzellati, N.
    Chiari, G.
    Rabaiotti, E.
    Corsi, A.
    Cacciani, G.
    Sommario, M.
    Ardizzoni, A.
    Zompatori, M.
    RADIOLOGIA MEDICA, 2008, 113 (07): : 945 - 953
  • [10] Classification of pulmonary blood vessel using multidetector-row CT images
    Mukaibo, T
    Kawata, Y
    Niki, N
    Ohmatsu, H
    Kakinuma, R
    Kaneko, M
    Eguchi, K
    Moriyama, K
    2001 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL II, PROCEEDINGS, 2001, : 841 - 844