Heat-power decoupling and energy saving of the CHP unit with heat pump based waste heat recovery system

被引:36
|
作者
Wang, Haichao [1 ,2 ]
Hua, Pengmin [2 ]
Wu, Xiaozhou [1 ]
Zhang, Ruoyu [3 ]
Granlund, Katja [4 ]
Li, Ji [5 ]
Zhu, Yingjie [1 ]
Lahdelma, Risto [2 ,6 ]
Teppo, Esa [4 ]
Yu, Li [4 ]
机构
[1] Dalian Univ Technol, Inst Bldg Environm & Facil Engn, Dalian 116024, Peoples R China
[2] Aalto Univ, Sch Sci, Dept Math & Syst Anal, POB 11100, Aalto, Finland
[3] Henan Prov Investment Co, Zhengzhou 450000, Peoples R China
[4] Planora Oy, PL 43,Voudintie 6, Oulu 90401, Finland
[5] China Acad Bldg Res, Inst Bldg Environm & Energy, Beijing 100013, Peoples R China
[6] Aalto Univ, Dept Mech Engn, POB 14100, FI-00076 Aalto, Finland
基金
芬兰科学院;
关键词
Electric heat pump (EHP); Absorption heat pump (AHP); Combined heat and power (CHP); Waste heat recovery; Heat-power decoupling; Energy saving; PLANT; TECHNOLOGIES; OPTIMIZATION; FLEXIBILITY; INTEGRATION; SIMULATION; CYCLE;
D O I
10.1016/j.energy.2022.123846
中图分类号
O414.1 [热力学];
学科分类号
摘要
Combined heat and power (CHP) plants are operating under more fluctuating working conditions due to the increasingly inconsistent demands for heat and power and integration of renewable energy. This paper proposes to use an electric heat pump (EHP) to decouple heat and power and save energy by recovering waste heat from the cooling water. The thermodynamic model of the CHP unit under dynamic working conditions is established, and the dynamic EHP model based on an efficiency factor is proposed. The heat-power decoupling and energy -saving potential with different heat and power outputs and the heat pump DH ratio (chi(HP)) are analyzed for a CHP unit as a case study. Absorption heat pump (AHP) and EHP-based waste heat recovery systems are also compared. The results indicate that the heat-power decoupling potential is bigger when chi(HP)& nbsp;and the heat demand are increasing. The energy -saving effect is clearer by increasing the coefficient of performance (COP), chi(HP), or both. AHP and EHP can help the system obtain a certain level of heat-power decoupling and energy -saving effects, but these effects of the AHP-based system are smaller than that of EHP, especially under the working conditions of high heat demand and low power demand. (C)& nbsp;2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Integrated unit commitment and economic dispatch of combined heat and power system considering heat-power decoupling retrofit of CHP unit
    Zhao, Teng
    Zheng, Yanan
    Li, Gengyin
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 143
  • [2] THERMODYNAMIC ANALYSIS ON A HEAT-POWER DECOUPLING SYSTEM INTEGRATED WITH ABSORPTION HEAT PUMP
    Wang, Liyuan
    Liu, Ming
    Fu, Yue
    Liu, Jiping
    Yan, Junjie
    [J]. PROCEEDINGS OF THE ASME 2020 POWER CONFERENCE (POWER2020), 2020,
  • [3] A NOVEL COAL-FIRED CHP SYSTEM INTEGRATED WITH STEAM EJECTORS TO REALIZE HEAT-POWER DECOUPLING AND ENERGY SAVING
    Liu, Miaomiao
    Liu, Ming
    Zhao, Shuran
    Song, Gege
    Yan, Junjie
    [J]. PROCEEDINGS OF THE ASME 2020 POWER CONFERENCE (POWER2020), 2020,
  • [4] Heat-power decoupling for the CHP unit by utilizing heat storage in the district heating system integrated with heat pumps: Dynamic modeling and performance analysis
    Wang, Liyuan
    Zhang, Shunqi
    Fu, Yue
    Liu, Ming
    Liu, Jiping
    Yan, Junjie
    [J]. ENERGY, 2024, 306
  • [5] Energy saving and flexibility analysis of combined heat and power systems integrating heat-power decoupling technologies in renewable energy accommodation
    Ma, Guofeng
    Liu, Ming
    Wang, Zhu
    Zhao, Yongliang
    Wang, Chaoyang
    Yan, Junjie
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2024, 310
  • [6] Research on Energy Saving Control Method of Waste Heat Recovery Pump System of Waste Water
    Zhang, Jia-Wei
    Pan, Lei
    Liu, Yu-Tong
    Fu, Yun-Kun
    Wang, Bei-Bei
    Liang, Yin
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (09): : 2250 - 2259
  • [7] Simulation study on a novel solar aided combined heat and power system for heat-power decoupling
    Ding, Zeyu
    Hou, Hongjuan
    Duan, Liqiang
    Huang, Chang
    Hu, Eric
    Yu, Gang
    Zhang, Yumeng
    Zhang, Nan
    [J]. ENERGY, 2021, 220
  • [8] Experimental study on energy saving between heat pump unit of heat recovery fresh air and heat pipe heat pump low temperature heat recovery unit in the cold and severe cold regions
    Li, Yang
    Liang, Xiu Juan
    [J]. ENERGY ENGINEERING AND ENVIRONMENT ENGINEERING, 2014, 535 : 37 - +
  • [9] Heating System Modification Schemes for Heat-Power Decoupling of Cogeneration Unit and Economic Analysis
    Yang, Haisheng
    Wang, Wenying
    [J]. 2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 917 - 921
  • [10] Energy Saving Analysis of Circulating Water Waste Heat Recovery from Water Source Heat Pump
    Ma, Chuang
    Ren, Jianxing
    Li, Fangqin
    Hou, Xin
    Feng, Haijun
    Zhang, Xiaotong
    [J]. 2019 5TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2019, 295