Numerical and experimental study of thermal efficiency of the transversal rectangular baffles with incline angle inside of solar air collector

被引:1
|
作者
Aouissi, Zouhair [1 ,2 ]
Chabane, Foued [1 ,2 ]
机构
[1] Univ Biskra, Dept Mech Engn, Biskra, Algeria
[2] Univ Biskra, Fac Technol, Lab Genie Mecan LGM, Biskra, Algeria
关键词
Thermal efficiency; baffles; CFD; solar air collector; friction coefficient; HEAT-TRANSFER COEFFICIENT; FLUID-FLOW; THERMOHYDRAULIC PERFORMANCE; DIFFERENT OBSTACLES; LONGITUDINAL FINS; EXERGY ANALYSIS; SHAPED RIBS; DUCT; ENHANCEMENT; FRICTION;
D O I
10.1080/15567036.2022.2128474
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study aims to improve the thermal and hydraulic performance of the solar air collector through rectangular baffles perpendicular to the air inside the channel (duct). In the latter, four cases were examined for the number and position of baffles (6 b, 10 b, 14 b, 18 b) with a fixed inclination angle of 135 degrees in the Reynolds range from Re = 5038 to Re = 10635 using Computational Fluid Dynamic (CFD) (Ansys Fluent 18.1). The turbulence model RNG k-epsilon was chosen because it gave closer results to the standard correlations of Dittus-Boelter and Modified Blasius, compared to the rest of the models. The validity of the CFD simulation was confirmed based on the experimental investigation. The study -of these cases shows that the increase in the number of baffles increases the average Nusselt number as well as the friction coefficient, where the highest value of Nusselt was recorded in the case of 18 baffles Nu = 49.40 at Re = 10257. The relationship between the positioning of the baffles and the local heat transfer coefficient was also concluded. The last three cases (10 b, 14 b, 18 b) gave a very close thermal-hydraulic performance factor (THPF), while the first case (6 b) is significantly greater than theirs by a significant percentage, where the highest value recorded THPF = 0.557 at Re = 5368. Throughout this work, the effect of baffles on the heat transfer from the absorber plate to the air was understood through the local heat transfer coefficient along the channel and the velocity fields and their rays. This said heat transfer was also perceived by adding this form of baffles in the four cases and their impact on the hydraulic and thermal performance of the collector.
引用
收藏
页码:8921 / 8942
页数:22
相关论文
共 50 条
  • [1] Experimental investigations on the thermal efficiency of a solar air collector with transverse rectangular baffles incline by an angle of 135°
    Chabane, Foued
    Aouissi, Zouhair
    [J]. Energy and Built Environment, 2024, 5 (04): : 544 - 555
  • [2] Experimental investigations on thermal efficiency of a prototype passive solar air collector with wavelike baffles
    Fiuk, Jacek Jan
    Dutkowski, Krzysztof
    [J]. SOLAR ENERGY, 2019, 188 : 495 - 506
  • [3] An experimental study on the thermal efficiency of a passive solar air collector
    Fiuk, Jacek Jan
    Dutkowski, Krzysztof
    Piątkowski, Piotr
    [J]. Engineering Transactions, 2017, 65 (02): : 251 - 268
  • [4] Experimental study on the thermal performance of a solar collector and the effect of the tilt angle on the collector efficiency
    Alkumait, A. R.
    Abed, F. M.
    Nashat, Mina A.
    [J]. INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING AND SCIENCE, 2018, 454
  • [5] Experimental Study of a Rectangular Storage Solar Collector with a numerical analysis
    Ahmed, Omer K.
    Daoud, Raid W.
    Mahmood, Omer T.
    [J]. 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENGINEERING TECHNIQUES (ICSET 2019), 2019, 518
  • [6] NUMERICAL SIMULATION AND EXPERIMENTAL STUDY ON SOLAR AIR COLLECTOR
    Li, W. F.
    Xu, S. H.
    Dong, H. G.
    You, J.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1301 - 1307
  • [7] Numerical analysis of mechanical ventilation solar air collector with internal baffles
    Hu, Jianjun
    Sun, Xishan
    Xu, Jinliang
    Li, Zhixian
    [J]. ENERGY AND BUILDINGS, 2013, 62 : 230 - 238
  • [8] Experimental and numerical study of the effect of integrating plus-shaped perforated baffles to solar air collector in drying application
    Khanlari, Ataollah
    Guler, Hande Ozge
    Tuncer, Azim Dogus
    Sirin, Ceylin
    Bilge, Yasar Can
    Yilmaz, Yusuf
    Gungor, Afsin
    [J]. RENEWABLE ENERGY, 2020, 145 : 1677 - 1692
  • [9] Experimental study of a solar air heater by adding an arrangement of transverse rectangular baffles perpendicular to the air stream
    Chabane, Foued
    Grira, Fares
    Moummi, Noureddine
    Brima, Abdelhafid
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2019, 16 (14) : 1264 - 1277
  • [10] Experimental Investigation of Thermal Efficiency of Solar Air Collector with Trapeze Absorber Plate
    Abuska, Mesut
    Akgul, Mehmet Bahattin
    [J]. JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2014, 17 (04): : 177 - 181