Energy recovery in air handling systems in non-residential buildings - design considerations

被引:0
|
作者
Markusson, Caroline [1 ]
Jagemar, Lennart [2 ]
Fahlen, Per [3 ]
机构
[1] Chalmers, Environm & Energy Dept, Div Bldg Serv Engn, S-41296 Gothenburg, Sweden
[2] CIT Energy Management AB, Gothenburg, Sweden
[3] Chalmers, Bldg Serv Engn, Dept Energy & Environm, Gothenburg, Sweden
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heating of supply air and drive energy to fans and pumps predominate the energy use of HVAC systems in non-residential buildings in cold, dry climates. Hence heat recovery and the effect on fan energy is of interest whereas recovery of cooling and moisture is less of an issue. This study looks at dedicated outdoor air systems with a run-around loop heat recovery or an enthalpy wheel heat recovery. In nonresidential buildings heat recovery with full capacity is used only during a part of the year but it still causes a pressure drop in the air round. In this situation the most energy efficient system with the highest temperature efficiency if one considers the If the value of electricity, compared to the value of heat, handling unit all year is not always the one penalty in fan energy is taken into account, the temperature efficiency might be even less important. In this case-study the enthalpy wheel with the lowest temperature efficiency was the most energy efficient choice on a system level. The same applies for the run-around loop systems, where the run-around loop with the lower temperature efficiency gave the better result. In the case of run-around loop systems there are different strategies for capacity control of the liquid flow to obtain optimal operation. Common alternatives are constant flow with variable temperature by means of a shunt group and variable flow by means flow control of a variable power is used compared to of two-way valve. A more energy efficient way is direct speed pump. In direct flow control a much smaller pump valve control. Shunt groups, in particular, result in pump power that is constant and unaffected by the real demand. Calculations based on measurements on a run-around loop system with direct flow control during three months show that the pump power after optimizing the flow can be reduced by 80 %.
引用
收藏
页码:154 / +
页数:2
相关论文
共 50 条
  • [1] Design optimization of air distribution systems in non-residential buildings
    Jorens, Sandy
    Verhaert, Ivan
    Sorensen, Kenneth
    [J]. ENERGY AND BUILDINGS, 2018, 175 : 48 - 56
  • [2] Heuristic optimization for designing centralized air distribution systems in non-residential buildings
    Kabbara, Zakarya
    Jorens, Sandy
    Matbouli, Houssam
    Van Thillo, Jitse
    Verhaert, Ivan
    [J]. ENERGY AND BUILDINGS, 2023, 292
  • [3] Demonstration of an MPC framework for all-air systems in non-residential buildings
    Merema, Bart
    Saelens, Dirk
    Breesch, Hilde
    [J]. BUILDING AND ENVIRONMENT, 2022, 217
  • [4] Energy Performance Aspects of Non-Residential Buildings in Latvia
    Kundzina, A.
    Geipele, I.
    Lapuke, S.
    Auders, M.
    [J]. LATVIAN JOURNAL OF PHYSICS AND TECHNICAL SCIENCES, 2022, 59 (06) : 30 - 42
  • [5] Design, Implementation and Demonstration of Embedded Agents for Energy Management in Non-Residential Buildings
    Constantin, Ana
    Loewen, Artur
    Ponci, Ferdinanda
    Mueller, Dirk
    Monti, Antonello
    [J]. ENERGIES, 2017, 10 (08)
  • [6] Industrial and non-residential buildings
    Dubina, D
    [J]. LIGHT GAUGE METAL STRUCTURES RECENT ADVANCES, 2005, (455): : 189 - 231
  • [7] COMPARATIVE STUDIES AND RESEARCH ON ENERGY OPTIMIZATION OF NON-RESIDENTIAL BUILDINGS
    Cziszter, K. I. A.
    Ionescu, G. C.
    Saracut-Ardelean, A. F.
    Szabo, S.
    Kovacs, T.
    Ionescu, G. L.
    [J]. JOURNAL OF APPLIED ENGINEERING SCIENCES, 2022, 12 (01) : 27 - 32
  • [8] Energy saving potential in retrofitting of non-residential buildings in Denmark
    Rose, Jorgen
    Thomse, Kirsten Engelund
    [J]. 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 1009 - 1014
  • [9] Benchmarking Energy Use of Existing Hellenic Non-Residential Buildings
    Droutsa, K. G.
    Kontoyiannidis, S.
    Dascalaki, E. G.
    Balaras, C. A.
    [J]. SUSTAINABLE SYNERGIES FROM BUILDINGS TO THE URBAN SCALE, 2017, 38 : 713 - 720
  • [10] Predictive control of multizone heating, ventilation and air-conditioning systems in non-residential buildings
    Garnier, Antoine
    Eynard, Julien
    Caussanel, Matthieu
    Grieu, Stephane