Water equivalent path length measurement in proton radiotherapy using time resolved diode dosimetry

被引:29
|
作者
Gottschalk, B. [1 ]
Tang, S. [2 ]
Bentefour, E. H. [3 ]
Cascio, E. W. [2 ]
Prieels, D. [3 ]
Lu, H. -M. [2 ]
机构
[1] Harvard Univ, Lab Particle Phys & Cosmol, Cambridge, MA 02138 USA
[2] Francis H Burr Proton Therapy Ctr, Boston, MA 02114 USA
[3] Ion Beam Applicat SA, B-1348 Louvain, Belgium
关键词
proton radiotherapy; water equivalent pathlength; time resolved dosimetry;
D O I
10.1118/1.3567498
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To verify water equivalent path length (WEPL) before treatment in proton radiotherapy using time resolved in vivo diode dosimetry. Methods: Using a passively scattered range modulated proton beam, the output of a diode driving a fast current-to-voltage amplifier is recorded at a number of depths in a water tank. At each depth, a burst of overlapping single proton pulses is observed. The rms duration of the burst is computed and the resulting data set is fitted with a cubic polynomial. Results: When the diode is subsequently set to an arbitrary depth and the polynomial is used as a calibration curve, the "unknown" depth is determined within 0.3 mm rms. Conclusions: A diode or a diode array, placed (for instance) in the rectum in conjunction with a rectal balloon, can potentially determine the WEPL at that point, just prior to treatment, with submillimeter accuracy, allowing the beam energy to be adjusted. The associated unwanted dose is about 0.2% of a typical single fraction treatment dose. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3567498]
引用
收藏
页码:2282 / 2288
页数:7
相关论文
共 50 条
  • [1] Feature Based Water Equivalent Path Length (WEPL) Determination for Proton Radiography by the Technique of Time Resolved Dose Measurement
    Zhang, R.
    Jee, K.
    Sharp, G.
    Flanz, J.
    Lu, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3325 - 3325
  • [2] Effective optical path length measurement of integrating cavity using time-resolved spectroscopy and tunable diode laser absorption spectroscopy
    Zhou, Xue
    Li, Haiwei
    Hu, Peng
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2022, 97
  • [3] Water-equivalent path length calibration of a prototype proton CT scanner
    Hurley, R. F.
    Schulte, R. W.
    Bashkirov, V. A.
    Wroe, A. J.
    Ghebremedhin, A.
    Sadrozinski, H. F. -W.
    Rykalin, V.
    Coutrakon, G.
    Koss, P.
    Patyal, B.
    MEDICAL PHYSICS, 2012, 39 (05) : 2438 - 2446
  • [4] In Vivo Proton Therapy Range Verification Using Time-Resolved Diode Dosimetry: Validation Through Numerical Modeling
    Toltz, A.
    Hoesl, M.
    Schuemann, J.
    Seuntjens, J.
    Lu, H.
    Paganetti, H.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [5] Benchmarking proton therapy water equivalent path length calculations against TPS algorithms
    Busch, K.
    Andersen, A. G.
    Petersen, J. B. B.
    Skyt, P. S.
    Norrevang, O.
    Muren, L. P.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S780 - S781
  • [6] Optimizing calibration settings for accurate water equivalent path length assessment using flat panel proton radiography
    Seller Oria, Carmen
    Marmitt, Gabriel Guterres
    Free, Jeffrey
    Langendijk, Johannes A.
    Both, Stefan
    Knopf, Antje C.
    Meijers, Arturs
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (21):
  • [7] Measurement of the effective optical path length of diffusing integrating cavities using time-resolved spectroscopy
    Zhou, Xue
    Yu, Jia
    Wang, Lin
    Zhang, Zhiguo
    APPLIED OPTICS, 2018, 57 (13) : 3519 - 3523
  • [8] Inferring Water Equivalent Path Length in Transmission Proton Imaging From Two Dimensional Data
    Van den Heuvel, F.
    Fiorini, F.
    MEDICAL PHYSICS, 2018, 45 (06) : E440 - E440
  • [9] Time-resolved diode dosimetry for in vivo proton therapy range verification: calibration through numerical modeling
    Toltz, Allison
    Hoesl, Michaela
    Schuemann, Jan
    Seuntjens, Jan
    Lu, Hsiao-Ming
    Paganetti, Harald
    MEDICAL PHYSICS, 2016, 43 (08) : 4939 - 4939
  • [10] Water equivalent properties of materials commonly used in proton dosimetry
    de Vera, Pablo
    Abril, Isabel
    Garcia-Molina, Rafael
    APPLIED RADIATION AND ISOTOPES, 2014, 83 : 122 - 127