Mechanism of formation of intravertebral clefts in osteoporotic vertebral compression fractures: An in vitro biomechanical study

被引:14
|
作者
Wang Chongyan [1 ]
Zhang, Xuyang [1 ]
Li, Shengyun [1 ]
Liu, Junhui [1 ]
Zhi Shan [1 ]
Wang, Jiasheng [1 ]
Jian Chen [1 ]
Fan, Shunwu [1 ]
Zhao, Fengdong [1 ]
机构
[1] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Dept Orthopaed, 3 East Qingchun Rd, Hangzhou 30016, Zhejiang, Peoples R China
来源
SPINE JOURNAL | 2018年 / 18卷 / 12期
基金
中国国家自然科学基金;
关键词
Basivertebral foramen; Cement leakage; Cyclic loading; Intravertebral cleft; Osteoporotic vertebral compression fracture; Vertebroplasty; VACUUM CLEFT; PERCUTANEOUS VERTEBROPLASTY; CEMENT LEAKAGE; SPINE; BEHAVIOR; BODY; SIGN;
D O I
10.1016/j.spinee.2018.07.020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Intravertebral clefts (IVCs) are vacuum-like cavities commonly associated with osteoporotic vertebral compression fractures (OVCFs). IVCs promote cement leakage during kyphoplasty, suggesting a physical link with the basivertebral foramen, although this is uncertain. PURPOSE: The present study aims to create IVCs in mechanical experiments on cadaveric spines in order to clarify their pathogenesis, structure, and links with the basivertebral foramen. STUDY DESIGN AND METHODS: In total, 15 three-vertebra lumbar specimens from five cadavers aged 68 to 71 years were subjected to axial compressive overload followed by cyclic loading in flexion and extension to create an OVCF together with an IVC. Computed tomography scans and radiographs were used to confirm structural changes and micro-CT was used to measure trabecular bone properties in five specimens. Unipedicular vertebroplasty was then performed on 10 damaged specimens until fluoroscopy revealed extravasation of cement. RESULTS: In every specimen, loading created an OVCF with an IVC. Dissection and imaging showed that the IVC was always connected with the basivertebral foramen. The central vertebral region, including the IVC, had the lowest connectivity density, trabecular number, and bone volume fraction, and the highest trabecular separation. Vertebroplasty caused cement leakage through the basivertebral foramen in nine specimens and into an adjacent disc in one specimen. CONCLUSION: Cyclic loading in flexion and extension applied to a fractured osteoporotic vertebra can create an IVC, which then allows cement leakage via the basivertebral foramen. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:2297 / 2301
页数:5
相关论文
共 50 条
  • [1] Intravertebral clefts in osteoporotic vertebral compression fractures
    McKiernan, F
    Faciszewski, T
    [J]. ARTHRITIS AND RHEUMATISM, 2003, 48 (05): : 1414 - 1419
  • [2] Comparison of vertebroplasty and kyphoplasty in the treatment of osteoporotic vertebral compression fractures with intravertebral clefts
    Kong L.-D.
    Wang P.
    Wang L.-F.
    Shen Y.
    Shang Z.-K.
    Meng L.-C.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (Suppl 1) : S201 - S208
  • [3] Pathomechanism of intravertebral clefts in osteoporotic compression fractures of the spine
    Kim, Yoon-Chung
    Kim, Young-Hoon
    Ha, Kee-Yong
    [J]. SPINE JOURNAL, 2014, 14 (04): : 659 - 666
  • [4] Osteoporotic vertebral compression fracture: the clinical impact of "intravertebral clefts"
    Leung, Yee
    Samartzis, Dino
    Cheung, Kenneth M. C.
    Luk, Keith D. K.
    [J]. SPINE JOURNAL, 2010, 10 (11): : 1035 - 1036
  • [5] Efficacy and safety of the target puncture technique for treatment of osteoporotic vertebral compression fractures with intravertebral clefts
    Yu, Weibo
    Liang, De
    Jiang, Xiaobing
    Yao, Zhensong
    Qiu, Ting
    Ye, Linqiang
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (11) : 1113 - +
  • [6] OSTEOPOROTIC VERTEBRAL COMPRESSION FRACTURES WITH INTRAVERTEBRAL VACUUM PHENOMENON
    KOEGER, AC
    CHAIBI, P
    ROZENBERG, S
    ROCHE, B
    BOURGEOIS, P
    [J]. ARTHRITIS AND RHEUMATISM, 1993, 36 (09): : S120 - S120
  • [7] Percutaneous vertebroplasty for vertebral compression fractures with and without intravertebral clefts
    Ha, K. -Y.
    Lee, J. -S.
    Kim, K. -W.
    Chon, J. -S.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05): : 629 - 633
  • [8] Vertebroplasty for vertebral fractures with intravertebral clefts
    Mathis, JM
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (10) : 1619 - 1620
  • [9] Intravertebral clefts in osteoporotic compression fractures of the spine: incidence, characteristics, and therapeutic efficacy
    Fang, Xiutong
    Yu, Fang
    Fu, Shengliang
    Song, Hongxing
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (09): : 16960 - 16968
  • [10] Cement Leakage in Percutaneous Vertebroplasty for Osteoporotic Compression Fractures With or Without Intravertebral Clefts
    Tanigawa, Noboru
    Kariya, Shuji
    Komemushi, Atsushi
    Tokuda, Takanori
    Nakatani, Miyuki
    Yagi, Rie
    Sawada, Satoshi
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) : W442 - W445