Third order sinusoidal integrator (TOSSI)-based control algorithm for shunt active power filter under distorted and unbalanced voltage conditions

被引:35
|
作者
Chilipi, Rajasekharareddy [1 ]
Al Sayari, Naji [1 ]
Al Hosani, Khalifa [1 ]
Fasil, Muhammed [1 ]
Beig, Abul R. [1 ]
机构
[1] Petr Inst, Elect Engn Dept, Abu Dhabi, U Arab Emirates
关键词
Shunt active power filter; Third order sinusoidal signal integrator; Point of common coupling; Harmonic currents filtering; Power quality; GRID SYNCHRONIZATION; CONVERTERS; NETWORK; DESIGN; PLL;
D O I
10.1016/j.ijepes.2017.09.026
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance of a shunt active power filter (SAPF) essentially depends on the accuracy of synchronization and harmonic components extraction, The conventional algorithms such as synchronous reference frame theory and instantaneous reactive power theory work well under sinusoidal and balanced grid voltage conditions. This research is mainly aimed at enhancing the performance of the SAPF when the grid voltages are unbalanced and distorted. The synchronizing signals of the voltage at the point of common coupling (PCC) and system frequency are extracted from the distorted voltages using third order sinusoidal signal integrator (TOSSI) based frequency adaptive pre-filters. In this study, the TOSSI-based filter is used to extract current harmonic components from the load current which increases the selectivity and the dynamic performance of extraction process. The performance of the proposed control approach for a SAPF under distorted and unbalanced voltage conditions is demonstrated through computer simulations and validated by experimental results.
引用
收藏
页码:152 / 162
页数:11
相关论文
共 50 条
  • [1] Current Reference Control for Shunt Active Power Filters Under Unbalanced and Distorted Supply Voltage Conditions
    Nie, Xiaohua
    Liu, Jijun
    [J]. IEEE ACCESS, 2019, 7 : 177048 - 177055
  • [2] Passivity-Based Direct power control of Shunt Active Filter under Distorted Grid Voltage Conditions
    Saidi, Salem
    Abbassi, Rabeh
    Amor, Nesrine
    Chebbi, Souad
    [J]. AUTOMATIKA, 2016, 57 (02) : 361 - 371
  • [3] Direct power control of shunt active filter using high selectivity filter (HSF) under distorted or unbalanced conditions
    Mesbahi, Nadhir
    Ouari, Ahmed
    Abdeslam, Djaffar Ould
    Djamah, Tounsia
    Omeiri, Amar
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2014, 108 : 113 - 123
  • [4] Control algorithm for an island microgrid under DSTATCOM using a Third Order Sinusoidal Integrator (TOSSI) to improve power quality for a local nonlinear load
    Bala, Nishi
    Mallik, Sanjeev Kumar
    [J]. ENGINEERING RESEARCH EXPRESS, 2024, 6 (02):
  • [5] A shunt active power filter control for unbalanced conditions
    Hosseini, SH
    Haque, MT
    Shahmohammadi, S
    [J]. ICECS 2003: PROCEEDINGS OF THE 2003 10TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-3, 2003, : 830 - 833
  • [6] Performance Improvement of Active Power Filter under Distorted and Unbalanced Grid Voltage Conditions
    Biricik, Samet
    Ozerdem, O. C.
    Redif, Soydan
    Kmail, M. I. O.
    [J]. ELEKTRONIKA IR ELEKTROTECHNIKA, 2013, 19 (01) : 35 - 39
  • [7] A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply Voltages
    Kanjiya, Parag
    Khadkikar, Vinod
    Zeineldin, Hatem H.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (12) : 5376 - 5390
  • [8] Constant Instantaneous Power Based Controller for a Shunt Active Power Filter under Balanced, Unbalanced, and Distorted Supply Conditions
    Khalid, Saifullah
    Dwivedi, Bharti
    Mishra, V. M.
    [J]. 2015 INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION & AUTOMATION (ICCCA), 2015, : 963 - 967
  • [9] Predictive Tuned Filter based Reference Current Generation for Shunt Active Power Filter under Distorted and Unbalanced Supply Voltage
    Gali, Vijayakumar
    Gupta, Nitin
    Gupta, R. A.
    [J]. 2018 NATIONAL POWER ENGINEERING CONFERENCE (NPEC), 2018,
  • [10] A New Voltage Sensorless Control Method for a Shunt Active Power Filter for Unbalanced Conditions
    Al-Gahtani, Saad
    Nelms, R. M.
    [J]. 2019 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2019 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2019,