A calibration-free lens distortion correction method for low cost digital imaging

被引:0
|
作者
Yu, W [1 ]
Chung, Y [1 ]
机构
[1] ETRI, CSTL, Spatial Informat Technol Ctr, Taejon 305350, South Korea
关键词
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
This paper describes a new lens distortion correction method suitable for consumer digital imaging and consequent mobile computing applications. First, a convenient way of camera calibration for lens distortion coefficient estimation is proposed with experimental validation. An image warping method for lens distortion removal is formulated by inverse spatial mapping; subsequently, an approximation scheme is proposed which is adapted for real-time application. Finally, the method is extended such that the calibration stage can be completely removed. Experimental results show that the proposed method effectively replaces costly calibration process and provides a distortion-free quality image.
引用
收藏
页码:813 / 816
页数:4
相关论文
共 50 条
  • [1] Publisher Correction: Calibration-free speckle matrix imaging
    Philipp del Hougne
    [J]. Light: Science & Applications, 11 (1)
  • [2] Model-free method for intrinsic camera parameters calibration and lens distortion correction
    Chen, Chao
    Yang, Fenglong
    Pan, Bing
    [J]. OPTICAL ENGINEERING, 2021, 60 (10)
  • [3] LENS DISTORTION CORRECTION WITH A CALIBRATION HARP
    von Gioi, R. Grompone
    Monasse, P.
    Morel, J. -M.
    Tang, Z.
    [J]. 2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011, : 617 - 620
  • [4] A simple new method for precise lens distortion correction of low cost camera systems
    Bräuer-Burchardt, C
    [J]. PATTERN RECOGNITION, 2004, 3175 : 570 - 577
  • [5] Calibration-free speckle matrix imaging
    Philipp del Hougne
    [J]. Light: Science & Applications, 11
  • [6] Calibration-free beam hardening correction for myocardial perfusion imaging using CT
    Levi, Jacob
    Eck, Brendan L.
    Fahmi, Rachid
    Wu, Hao
    Vembar, Mani
    Dhanantwari, Amar
    Fares, Anas
    Bezerra, Hiram G.
    Wilson, David L.
    [J]. MEDICAL PHYSICS, 2019, 46 (04) : 1648 - 1662
  • [7] A calibration-free electrode compensation method
    Rossant, Cyrille
    Fontaine, Bertrand
    Magnusson, Anna K.
    Brette, Romain
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 2012, 108 (09) : 2629 - 2639
  • [8] Low Cost, Calibration-free Sensors for In Situ Determination of Natural Water Pollution
    Radu, A.
    Anastasova, S.
    Fay, C.
    Diamond, D.
    Bobacka, J.
    Lewenstam, A.
    [J]. 2010 IEEE SENSORS, 2010, : 1487 - 1490
  • [9] Calibration and correction of lens distortion for two-dimensional digital speckle correlation measurement
    Zhao, Jian
    Zhao, Dong
    Zhang, Zhe
    [J]. OPTIK, 2013, 124 (23): : 6042 - 6047
  • [10] Calibration-Free Nanopore Digital Counting of Single Molecules
    Nouri, Reza
    Tang, Zifan
    Guan, Weihua
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (17) : 11178 - 11184