Quantification of coronary artery stenosis with 16-slice MSCT in patients before CABG surgery: Comparison to standard invasive coronary angiography

被引:12
|
作者
Probst, C
Kovacs, A
Schmitz, C
Schiller, W
Schild, H
Welz, A
机构
[1] Univ Bonn, Dept Cardiac Surg, D-53127 Bonn, Germany
[2] Univ Bonn, Dept Radiol, D-53127 Bonn, Germany
来源
HEART SURGERY FORUM | 2005年 / 8卷 / 01期
关键词
D O I
10.1532/HSF98.20041144
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Invasive, selective coronary angiography is the gold standard for evaluation of coronary artery disease ( CAD) and degree of stenosis. The purpose of this study was to compare 3-dimensional (3D) reconstructed 16-slice multislice computed tomographic (MSCT) angiography and selective coronary angiography in patients before elective coronary artery bypass graft (CABG) procedure. Methods: Sixteen-slice MSCT scans (Philips Mx8000 IDT) were performed in 50 patients ( 42 male/8 female; mean age, 64.44 +/- 8.66 years) scheduled for elective CABG procedure. Scans were retrospectively electrocardiogram-gated 3D reconstructed. The images of the coronary arteries were evaluated for stenosis by 2 independent radiologists. The results were compared with the coronary angiography findings using the American Heart Association segmental classification for coronary arteries. Results: Four patients (8%) were excluded for technical reasons. Thirty-eight patients (82.6%) had 3-vessel disease, 4 (8.7%) had 2-vessel disease, and 4 ( 8.7%) had an isolated left anterior descending artery stenosis. In the proximal segments all stenoses > 50% (56/56) were detected by MSCT; medial segment sensitivity was 97% (73/75), specificity 90.3%; distal segment sensitivity was 90.7% (59/65), specificity 77%. Conclusion: Accurate quanti. cation of coronary stenosis greater than 50% in the proximal and medial segments is possible with high sensitivity and specificity using the new generation of 16-slice MSCTs. There is still a tendency to overestimate stenosis in the distal segments. MSCT seems to be an excellent diagnostic tool for screening patients with possible CAD.
引用
收藏
页码:E42 / E46
页数:5
相关论文
共 50 条
  • [1] The accuracy of 4-slice computer tomography and 16-slice computer tomography in the detection and quantification of significant (50%) coronary artery stenosis in comparison with coronary angiography
    Pasowicz, M
    Klimeczek, P
    Zajdel, W
    Bany, R
    Zmudka, K
    EUROPEAN HEART JOURNAL, 2004, 25 : 117 - 117
  • [2] Validation of non-invasive coronary angiography by 16-slice multidetector spiral computed tomography in comparison to invasive coronary angiography
    Kaiser, C
    Pater, S
    Bremerich, J
    Bongartz, G
    Steinbrich, W
    Pfisterer, M
    Buser, P
    EUROPEAN HEART JOURNAL, 2003, 24 : 725 - 725
  • [3] Validation of non-invasive coronary angiography by 16-slice multidetector spiral computed tomography in comparison to invasive coronary angiography
    Kaiser, C
    Pater, S
    Bremerich, J
    Bongartz, G
    Steinbrich, W
    Pfisterer, M
    Buser, P
    CIRCULATION, 2003, 108 (17) : 672 - 672
  • [4] Noninvasive Detection of Coronary Artery Stenosis Using 16-slice Spiral CT: a Comparison with Selective X-ray Coronary Angiography
    史河水
    韩萍
    孔祥泉
    冯敢生
    Martin HK Hoffmann
    华中科技大学学报(医学英德文版), 2006, (03) : 338 - 340
  • [5] Noninvasive detection of coronary artery stenosis using 16-slice spiral CT: A comparison with selective X-ray coronary angiography
    Shi Heshui
    Han Ping
    Kong Xiangquan
    Feng Gangsheng
    Martin HK Hoffmann
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2006, 26 (3): : 338 - 340
  • [6] Diagnostic accuracy of 16-slice CT coronary angiography in the evaluation of coronary artery disease
    Soon, K. H.
    Chaitowitz, I.
    Cox, N.
    MacGregor, L.
    Eccleston, D.
    Bell, K. W.
    Kelly, A-M
    Lim, Y. L.
    AUSTRALASIAN RADIOLOGY, 2007, 51 (04): : 365 - 369
  • [7] CABG patients: better coronary CT before invasive coronary angiography?
    Dahm, Johannes B.
    AKTUELLE KARDIOLOGIE, 2024, 13 (01)
  • [8] Coronary stenosis detection by 16-slice computed tomography in heart transplanted patients: Comparison with conventional coronary angiography and impact on clinical management
    Romeo, G
    Houyel, L
    Paul, JF
    Brenot, P
    Riou, JY
    Angel, CY
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 283A - 283A
  • [9] Coronary Angiography by 16-Slice Computed Tomography Prior to Valvular Surgery
    Rodriguez-Palomares, Jose F.
    Cuellar, Hug
    Marti, Gerard
    Garcia, Bruno
    Teresa Gonzalez-Alujas, M.
    Mahia, Patricia
    Evangelista, Arturo
    Tornos, Pilar
    Garcia-Dorado, David
    REVISTA ESPANOLA DE CARDIOLOGIA, 2011, 64 (04): : 269 - 276
  • [10] Coronary stenosis detection by 16-slice computed tomography in heart transplant patients: Comparison with conventional coronary angiography and impact on clinical management
    Romeo, G.
    Houyel, L.
    Paul, J. F.
    Brenot, P.
    Riou, J. Y.
    Angel, C. Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02): : S114 - S114