Cross-Cultural Adaptation, Validation, and Arabic Translation of the Eustachian Tube Dysfunction Questionnaire (ETDQ-7)

被引:2
|
作者
Alkholaiwi, Feras [1 ]
Alnatheer, Abdullah M. [2 ]
Theyab, Rami Saud [4 ]
Alyousef, Meshal [2 ]
Aldrees, Turki [5 ]
Bin Dahmash, Abdulmajeed [3 ]
Alghonaim, Yazeed [6 ]
机构
[1] Imam Mohammad Ibn Saud Islamic Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, Riyadh, Saudi Arabia
[2] Imam Mohammed Ibn Saud Islamic Univ, Coll Med, Othman Bin Affan Rd Alnada 7544, Riyadh 133174233, Saudi Arabia
[3] Minist Hlth, Ad Diriyah Hosp, Riyadh, Saudi Arabia
[4] King Saud Univ, King Abdulaziz Univ Hosp, Dept Audiol, Riyadh, Saudi Arabia
[5] Prince Sattam Bin Abdulaziz Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, Alkharj, Saudi Arabia
[6] King Saud Bin Abdulaziz Univ Hlth Sci, Div Otorhinolaryngol Head & Neck Surg, Minist Natl Guard Hlth Affairs, King Abdulaziz Med City, Riyadh, Saudi Arabia
关键词
eustachian tube; validation study; translation; SONOTUBOMETRY; DILATION; HISTORY; ADULTS; TESTS;
D O I
10.1055/s-0041-1740161
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Introduction The Eustachian Tube Dysfunction Patient Questionnaire (ETDQ-7) scale is used to assess the effectiveness of the treatment and to determine the severity of the eustachian tube dysfunction (ETD). There is currently no validated Arabic version of the ETDQ-7. Objectives The aim of the present study is to test the validity and the reliability of a translated Arabic version of the ETDQ-7. Methods A multicenter prospective validation study was conducted in Riyadh, Saudi Arabia. The ETDQ-7 was adapted and translated into Arabic using a standard validation methodology. Fifty-one patients diagnosed with Eustachian tube dysfunction and 45 healthy individuals were enrolled in the study. The known-groups method was used in the validity analysis. The test-retest method, item-total score correlation, and internal consistency analysis were used for the reliability analyses. Result The overall internal consistency of the Arabic ETDQ items was measured using Cronbach alpha (Cronbach alpha = 0.803). The average and total ETDQ scores were significantly higher in the ETD group (17.6) than in the control group (9.87) ( p < 0.001). The results indicate a good to excellent correlation (> 0.7). The area under the curve for the total ETDQ score was 88.6% (95% confidence interval [CI]: 80.3-96.8%) Conclusion The Arabic version of the ETDQ-7 scale is a valid instrument for evaluating ETD. It can also be used as an important tool for diagnosis, patient follow-up, and treatment management.
引用
收藏
页码:636 / 642
页数:7
相关论文
共 50 条
  • [1] Translation, validation and cultural adaptation of "The Eustachian Tube Dysfunction Questionnaire-7" (ETDQ-7) to Brazilian Portuguese (BR)
    Gallardo, Fernanda Pires
    Onishi, Ektor Tsuneo
    Lira, Francisco Iure
    Suzuki, Flavia Barros
    Gurgel Testa, Jose Ricardo
    [J]. BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2019, 85 (04) : 456 - 464
  • [2] Validating the clinical assessment of eustachian tube dysfunction: The eustachian tube dysfunction questionnaire (ETDQ-7)
    McCoul, Edward D.
    Anand, Vijay K.
    Christos, Paul J.
    [J]. LARYNGOSCOPE, 2012, 122 (05): : 1137 - 1141
  • [3] Malay Language Translation and Validation of the Seven-item Eustachian Tube Dysfunction Questionnaire [ETDQ-7(M)]
    Heng, Y. T.
    Abdullah, A.
    Afandi, A. N.
    Hashima, N. D.
    [J]. IIUM MEDICAL JOURNAL MALAYSIA, 2023, 22 (03): : 140 - 146
  • [4] The efficacy of the Eustachian Tube Dysfunction Questionnaire (ETDQ-7) for patulous Eustachian tube patient
    Ikeda, Ryoukichi
    Kikuchi, Toshiaki
    Miyazaki, Hiromitsu
    Hidaka, Hiroshi
    Kawase, Tetsuaki
    Katori, Yukio
    Kobayashi, Toshimitsu
    [J]. ACTA OTO-LARYNGOLOGICA, 2018, 138 (01) : 6 - 9
  • [5] Clinical assessment of Eustachian tube dysfunction through the Eustachian tube dysfunction questionnaire (ETDQ-7) and tubomanometry
    Herrera, Mayte
    Eisenberg, Gustavo
    Plaza, Guillermo
    [J]. ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2019, 70 (05): : 265 - 271
  • [6] Accuracy of the ETDQ-7 for Identifying Persons with Eustachian Tube Dysfunction
    Teixeira, Miriam S.
    Swarts, J. Douglas
    Alper, Cuneyt M.
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2018, 158 (01) : 83 - 89
  • [7] Assessment of Functional Disorder of the Eustachian Tube with the ETDQ-7
    Kessing, Richard
    [J]. LARYNGO-RHINO-OTOLOGIE, 2019, 98 (02) : 72 - 73
  • [8] UTILIZING ETDQ-7 AS A TOOL TO PREDICT THE BETTER MEDICAL INTERVENTION FOR EUSTACHIAN TUBE DYSFUNCTION
    Toti, Sarah
    Peraza, Lazaro
    Zamboni, Anthony
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2020, 68 (05) : 1079 - 1080
  • [9] ASSESSING THE VALIDITY OF THE ETDQ-7 SURVEY QUESTIONS BASED ON EUSTACHIAN TUBE DYSFUNCTION OUTCOMES
    Toti, Sarah
    Peraza, Lazaro
    Zamboni, Anthony
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2020, 68 (05) : 1084 - 1085
  • [10] Assessment of Functional Disorder of the Eustachian Tube with the ETDQ-7 Comment
    Todt, Ingo
    [J]. LARYNGO-RHINO-OTOLOGIE, 2019, 98 (02) : 73 - +