Virtual patient trials of a multi-input stochastic model for tight glycaemic control using insulin sensitivity and blood glucose data

被引:4
|
作者
Davidson, Shaun M. [1 ]
Uyttendaele, Vincent [2 ]
Pretty, Christopher G. [1 ]
Knopp, Jennifer L. [1 ]
Desaive, Thomas [2 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Christchurch, New Zealand
[2] Univ Liege, GIGA Cardiovasc Sci, Liege, Belgium
关键词
Glycaemic control; Stochastic model; Gaussian Kernel; Insulin sensitivity; Stochastic targeted; Virtual trials; MORTALITY; THERAPY; HYPOGLYCEMIA; DEATH; RISK;
D O I
10.1016/j.bspc.2020.101896
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Safe, effective glycaemic control (GC) requires accurate prediction of future patient insulin sensitivity (SI), balancing the risk of hyper- and hypo-glycaemia. The stochastic targeted (STAR) protocol combines a clinically validated metabolic model and SI metric with a risk-based stochastic approach to optimise patient specific insulin and feed rates. Validated virtual trials comparing a novel 3D stochastic model for prediction of future patient SI using current patient SI and current blood glucose (BG) to an existing 2D stochastic model for SI prediction were conducted. Methods: The virtual trials involved 1477 retrospective patients across two hospitals and two GC protocols. They were conducted using five-fold cross-validation to build each stochastic model, ensuring independent test data. Results: The 3D stochastic model shifted BG from the 4.4-8.0 mmol/L target band towards the lower 4.4-6.5 mmol/L band, providing a decrease from 12.31 % to 11.19 % in hyperglycaemic hours (BG > 8.0 mmol/L), but only a 0.24 % increase, from 1.01 % to 1.25 %, in light hypoglycaemic hours (BG < 4.0 mmol/L). Simultaneously, the 3D stochastic model enabled greater patient nutrition, and required negligible increase in computational or clinical workload. Conclusions: The 3D stochastic model provided greater personalisation and better realised STAR's design philosophy of minimising hyperglycaemic events for an acceptable clinical risk of 5.0 % BG < 4.4 mmol/L. Thus, this model could provide better clinical conformity to design targets if implemented within the STAR protocol. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:7
相关论文
共 38 条
  • [1] Multi-input stochastic prediction of insulin sensitivity for tight glycaemic control using insulin sensitivity and blood glucose data
    Davidson, Shaun
    Pretty, Chris
    Uyttendaele, Vincent
    Knopp, Jennifer
    Desaive, Thomas
    Chase, J. Geoffrey
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2019, 182
  • [2] Uncertainties in the measurement of blood glucose in paediatric intensive care: implications for clinical trials of tight glycaemic control
    Hill, Helen
    Baines, Paul
    Barton, Paul
    Newland, Paul
    Terlouw, Dianne
    Turner, Mark
    INTENSIVE CARE MEDICINE, 2011, 37 (09) : 1517 - 1524
  • [3] Uncertainties in the measurement of blood glucose in paediatric intensive care: implications for clinical trials of tight glycaemic control
    Helen Hill
    Paul Baines
    Paul Barton
    Paul Newland
    Dianne Terlouw
    Mark Turner
    Intensive Care Medicine, 2011, 37
  • [4] Comparison of capillary and interstitial blood glucose measurements in patients undergoing tight glycaemic control with insulin on an acute medical unit
    Misra, Shivani
    Archer, John
    Hing, Doug
    Getov, Spas
    Simmgen, Marcus
    Millard, Jane
    Jones, Paul
    Baker, Emma
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2009, 68 (02) : 293 - 293
  • [5] Multi-input multi-output control of a continuous fermenter using nonlinear model based controllers
    Saha, Prabirkumar
    Hu, Qiuping
    Rangaiah, Gade Pandu
    Bioprocess and Biosystems Engineering, 21 (06): : 533 - 542
  • [6] Multi-input multi-output control of a continuous fermenter using nonlinear model based controllers
    Prabirkumar Saha
    Qiuping Hu
    Gade Pandu Rangaiah
    Bioprocess Engineering, 1999, 21 : 533 - 542
  • [7] Multi-input multi-output control of a continuous fermenter using nonlinear model based controllers
    Saha, P
    Hu, QP
    Rangaiah, GP
    BIOPROCESS ENGINEERING, 1999, 21 (06) : 533 - 542
  • [8] Performance of Stochastic Targeted Blood Glucose Control Protocol by virtual trials in the Malaysian intensive care unit
    Jamaludin, Ummu K.
    Suhaimi, Fatanah M.
    Razak, Normy Norfiza Abdul
    Ralib, Azrina Md
    Nor, Mohd Basri Mat
    Pretty, Christopher G.
    Humaidi, Luqman
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2018, 162 : 149 - 155
  • [9] Classification of Humans and Animals from Radar Signals using Multi-Input Mixed Data Model
    Tiwari, Alarsh
    Goomer, Rushil
    Yenneti, Shanmukha S. S.
    Mehta, Sonali
    Mishra, Vipul
    2021 INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATION AND INFORMATICS (ICCCI), 2021,
  • [10] Association of self monitoring of blood glucose, medication adherence, and glycaemic control in diabetes patients not using insulin
    Virdi, N. S.
    Raja, P.
    Daskiran, M.
    Kozma, C.
    Nigam, S.
    DIABETOLOGIA, 2011, 54 : S393 - S394