A systems-based assessment of the PrePex device adverse events active surveillance system in Zimbabwe

被引:2
|
作者
Adamson, Paul C. [1 ,2 ,6 ]
Tafuma, Taurayi A. [3 ]
Davis, Stephanie M. [4 ]
Xaba, Sinokuthemba [5 ]
Herman-Roloff, Amy [3 ,7 ]
机构
[1] Univ Calif San Francisco, Sch Med, San Francisco, CA 94143 USA
[2] Ctr Dis Control & Prevent, CDC Hubert Global Hlth Fellowship, Div Sci Educ & Profess Dev, Atlanta, GA 30333 USA
[3] US Ctr Dis Control & Prevent, Harare, Zimbabwe
[4] US Ctr Dis Control & Prevent, Atlanta, GA USA
[5] Minist Hlth & Child Care, AIDS & TB Programme, Harare, Zimbabwe
[6] Yale Univ, Sch Med, Dept Internal Med, New Haven, CT 06510 USA
[7] US Ctr Dis Control & Prevent, Pretoria, South Africa
来源
PLOS ONE | 2017年 / 12卷 / 12期
关键词
CIRCUMCISION;
D O I
10.1371/journal.pone.0190055
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Voluntary Medical Male Circumcision (VMMC) is an effective method for HIV prevention and the World Health Organization (WHO) has recommended its expansion in 14 African countries with a high prevalence of HIV and low prevalence of male circumcision. The WHO has recently pre-qualified the PrePex device, a non-surgical male circumcision device, which reduces procedure time, can increase acceptability of VMMC, and can expand the set of potential provider cadres. The PrePex device was introduced in Zimbabwe as a way to scale-up VMMC services in the country. With the rapid scale-up of the PrePex device, as well as other similar devices, a strong surveillance system to detect adverse events (AE) is needed to monitor the safety profile of these devices. We performed a systems-based evaluation of the PrePex device AE active surveillance system in Zimbabwe. Methods The evaluation was based on the Centers for Disease Control and Prevention's Updated Guidelines for Evaluating Public Health Surveillance Systems. We adapted these guidelines to fit our local context. The evaluation incorporated the review of the standard operating procedures and surveillance system documents. Additionally, structured, in-person interviews were performed with key stakeholders who were users of the surveillance system at various levels. These key stakeholders were from the Ministry of Health, implementing partners, and health facilities in Harare. Results Clients were requested to return to the facility for follow-up on days 7, 14 and 49 after placement of the device. In the event of a severe AE, a standard report was generated by the health facility and relayed to the Ministry of Health Child and Care and donor agencies through predefined channels within 24 hours of diagnosis. Clinic staff reported difficulties with the amount of documentation required to follow up with clients and to report AEs. The surveillance system's acceptability among users interviewed was high, and users were motivated to identify all possible AEs related to this device. The surveillance system was purely paper-based and both duplicate and discrepant reporting forms between sites were identified. Conclusion The PrePex AE active surveillance system was well accepted among participants in the health system. However, the amount of documentation which was required to follow-up with patients was a major barrier within the system, and might lead to decreased timeliness and quality of reporting. A passive surveillance system supported by electronic reporting would improve acceptance of the program.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] PrePex circumcision surveillance: Adverse events and analgesia for device removal
    Lebina, Limakatso
    Milovanovic, Minja
    Otwombe, Kennedy
    Abraham, Pattamukkil
    Manentsa, Mmatsie
    Nzenze, Susan
    Martinson, Neil
    PLOS ONE, 2018, 13 (03):
  • [2] Safety and Acceptability of the PrePex Device When Used in Routine Male Circumcision Service Delivery During Active Surveillance in Zimbabwe
    Mavhu, Webster
    Hatzold, Karin
    Ncube, Getrude
    Xaba, Sinokuthemba
    Madidi, Ngonidzashe
    Keatinge, Jo
    Dhodho, Efison
    Samkange, Christopher A.
    Tshimanga, Mufuta
    Mangwiro, Tonderayi
    Mugurungi, Owen
    Njeuhmeli, Emmanuel
    Cowan, Frances M.
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2016, 72 : S63 - S68
  • [3] Active surveillance for influenza vaccine adverse events: The integrated vaccine surveillance system
    Newes-Adeyi, Gabriella
    Greece, Jacey
    Bozeman, Sam
    Walker, Deborah Klein
    Lewis, Faith
    Gidudu, Jane
    VACCINE, 2012, 30 (06) : 1050 - 1055
  • [4] Pharmacovigilance: An Active Surveillance System to Proactively Identify Risks for Adverse Events
    Moses, Christopher
    Celi, Leo A.
    Marshall, John
    POPULATION HEALTH MANAGEMENT, 2013, 16 (03) : 147 - 149
  • [5] Active surveillance for adverse events following immunization
    Crawford, Nigel W.
    Clothier, Hazel
    Hodgson, Kate
    Selvaraj, Gowri
    Easton, Mee Lee
    Buttery, Jim P.
    EXPERT REVIEW OF VACCINES, 2014, 13 (02) : 265 - 276
  • [6] System and facility readiness assessment for conducting active surveillance of adverse events following immunization in Addis Ababa, Ethiopia
    Zeleke, Eden Dagnachew
    Yimer, Getnet
    Lisanework, Leuel
    Chen, Robert T.
    Huang, Wan-Ting
    Wang, Shu-Hua
    Bennett, Sarah D.
    Makonnen, Eyasu
    INTERNATIONAL HEALTH, 2023, 15 (06): : 676 - 683
  • [7] Active surveillance of vaccine safety - A system to detect early signs of adverse events
    Davis, RL
    Kolczak, M
    Lewis, E
    Nordin, J
    Goodman, M
    Shay, DK
    Platt, R
    Black, S
    Shinefield, H
    Chen, RT
    EPIDEMIOLOGY, 2005, 16 (03) : 336 - 341
  • [8] Adverse Events Profile of PrePex a Non-Surgical Device for Adult Male Circumcision in a Ugandan Urban Setting
    Galukande, Moses
    Duffy, Kevin
    Bitega, Jean Paul
    Rackara, Sam
    Bbaale, Denis Sekavuga
    Nakaggwa, Florence
    Nagaddya, Teddy
    Wooding, Nick
    Dea, Monica
    Coutinho, Alex
    PLOS ONE, 2014, 9 (01):
  • [9] Is the PrePex device an alternative for surgical male circumcision in adolescents ages 13-17 years? Findings from routine service delivery during active surveillance in Zimbabwe
    Mavhu, Webster
    Hatzold, Karin
    Madidi, Ngonidzashe
    Maponga, Brian
    Dhlamini, Roy
    Munjoma, Malvern
    Xaba, Sinokuthemba
    Ncube, Getrude
    Mugurungi, Owen
    Cowan, Frances M.
    PLOS ONE, 2019, 14 (03):
  • [10] Active Postmarketing Drug Surveillance for Multiple Adverse Events
    Goh, Joel
    Bjarnadottir, Margret V.
    Bayati, Mohsen
    Zenios, Stefanos A.
    OPERATIONS RESEARCH, 2015, 63 (06) : 1528 - 1546