Assessment of Sub-synchronous Resonance Analysis Techniques in Series Compensated Line

被引:0
|
作者
Unverdi Aglar, Ezgi [1 ]
Capar, Alkim [1 ]
Basa Arsoy, Aysen [1 ]
机构
[1] Kocaeli Univ, Dept Elect Engn, Kocaeli, Turkey
关键词
Sub-synchronous resonance (SSR); Induction generator effect (IGE); Torsional interaction (TI); Torque amplification (TA); Eigenvalue analysis; Electromagnetic transient analysis technique;
D O I
10.1145/3284557.3284732
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Series compensation of transmission lines is essential for power systems transfer capability enhancement, reactive power equipment and steady-state voltage stability in power systems. However, it leads to increase the risk of sub-synchronous resonance. Sub-synchronous resonance is one of the most critical issue to power system stability which can be described as general oscillation problem at one or more frequency below synchronous frequency. Frequency scanning technique, eigenvalue analysis technique and electromagnetic transient analysis technique are frequently used in the literature for the purpose of analysis sub synchronous resonance in power systems. In this paper, Using IEEE first benchmark model (FBM), the susceptibility of the system to the SSR is investigated by the eigenvalue technique and electromagnetic transient analysis technique. PSCAD/EMTDC tools is used for electromagnetic transient analysis technique. Furthermore, the susceptibilities of the system are compared for different compensation levels in this study.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Sub-synchronous resonance in series compensated wind farm: A review
    Virulkar, V. B.
    Gotmare, G. V.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 55 : 1010 - 1029
  • [2] Continuous non-linear model of series compensated transmission line for sub-synchronous resonance investigation
    Al Dabbagh, M
    Yousif, N
    Graszkiewicz, P
    [J]. Proceedings of the Fourth IASTED International Conference on Power and Energy Systems, 2004, : 567 - 571
  • [3] Qualitative and Quantitative Analysis of Sub-synchronous Resonance for a 500 kV Series Compensated Transmission System
    Peng, Peipei
    He, Jieqiong
    Zhang, Lei
    Jiang, Dajun
    [J]. 2017 IEEE 7TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2017, : 1273 - 1278
  • [4] Sub-Synchronous Resonance Damping in Series Compensated Transmission Lines Using a STATCOM in the Common Bus
    Khalilinia, H.
    Ghaisari, J.
    [J]. 2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 822 - 828
  • [5] Sub-Synchronous Resonance (SSR) in Series Compensated Networks with High Penetration of Renewable Energy Sources
    Chikohora, Tinashe E.
    Oyedokun, David To
    [J]. 2020 INTERNATIONAL SAUPEC/ROBMECH/PRASA CONFERENCE, 2020, : 866 - 871
  • [6] Analysis of Sub-synchronous Oscillation of Direct-drive Wind Farm Series Compensated Line with Prony Method
    Wang, Min
    Xi, Xingze
    Quo, Cheng
    Huang, Yingbo
    Na, Jing
    [J]. 2023 35TH CHINESE CONTROL AND DECISION CONFERENCE, CCDC, 2023, : 44 - 50
  • [7] Sub-synchronous resonance in grid-forming PMSGs connected to series-compensated networks
    Han Jiang
    Zhengchun Du
    Xiaotian Yuan
    Jinlong Han
    [J]. Journal of Power Electronics, 2024, 24 : 618 - 630
  • [8] Sub-synchronous resonance in grid-forming PMSGs connected to series-compensated networks
    Jiang, Han
    Du, Zhengchun
    Yuan, Xiaotian
    Han, Jinlong
    [J]. JOURNAL OF POWER ELECTRONICS, 2024, 24 (04) : 618 - 630
  • [9] Sub-Synchronous Resonance (SSR) in Series Compensated Networks with High Penetration of Renewable Energy Sources
    Chikohora, Tinashe E.
    [J]. 2019 IEEE AFRICON, 2019,
  • [10] Application of Static Synchronous Series Compensator to damp Sub-Synchronous Resonance
    Barati, Hassan
    Ara, Afshin Lashkar
    Ehsan, A.
    Fotuhi-Firtizabad, M.
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONIC, DRIVES AND ENERGY SYSTEMS, VOLS 1 AND 2, 2006, : 1096 - +