Quantitative assessment of regional variation in tissue clearing efficiency using optical coherence tomography (OCT) and magnetic resonance imaging (MRI): A feasibility study

被引:11
|
作者
Baek, Kwangyeol [1 ]
Jung, Sunwoo [1 ]
Lee, Junwon [1 ]
Min, Eunjung [2 ]
Jung, Woonggyu [1 ]
Cho, Hyungjoon [1 ]
机构
[1] UNIST, Dept Biomed Engn, Ulsan, South Korea
[2] Rowland Inst Harvard, 100 Edwin H Land Blvd, Cambridge, MA 02142 USA
基金
新加坡国家研究基金会;
关键词
ATTENUATION COEFFICIENTS; RECONSTRUCTION; MICROSCOPY;
D O I
10.1038/s41598-019-39634-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Tissue clearing has gained attention as a pioneering research tool for imaging of large tissue samples. This technique improves light transmission by reducing light scattering within tissues, either by removing lipids or by replacing water with a high refractive index solution. Although various clearing techniques have been developed, quantitative assessments on clearing efficacy depending on tissue properties are rare. In this study, we developed the quantitative mapping of regional clearing efficacy using mean free path in optical coherence tomography (OCT) and proton density in magnetic resonance imaging (MRI), and demonstrated its feasibility in the brain sample with four representative clearing techniques (benzyl alcohol and benzyl benzoate [BABB], Clear(T), Scale, and passive CLARITY technique [PACT]). BABB (solvent-based clearing), involving both refractive index matching and lipid removal, exhibited best optical clearing performance with the highest proton density reduction both in gray and white matter. Lipid-removing techniques such as Scale (aqueous hyperhydration) and PACT (hydrogel embedding) showed higher clearing efficiency in white matter than gray matter in accordance with larger proton density increase in white matter. For Clear(T) (aqueous-based simple immersion), we observed lowest clearing efficiency in the white matter as well as poor lipid removal reflected in low proton density reduction. Our results showed the feasibility of the regional mapping of clearing efficacy and correlating optical transparency and proton density changes using OCT and MRI from existing tissue clearing techniques. This novel quantitative mapping of clearing efficacy depending on tissue types and clearing methods may be helpful in the development of optimized clearing methods for different biological samples.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Quantitative assessment of regional variation in tissue clearing efficiency using optical coherence tomography (OCT) and magnetic resonance imaging (MRI): A feasibility study
    Kwangyeol Baek
    Sunwoo Jung
    Junwon Lee
    Eunjung Min
    Woonggyu Jung
    Hyungjoon Cho
    [J]. Scientific Reports, 9
  • [2] ASSESSMENT OF TISSUE OPTICAL CLEARING AS A FUNCTION OF GLUCOSE CONCENTRATION USING OPTICAL COHERENCE TOMOGRAPHY
    Sudheendran, Narendran
    Mohamed, Mohamed
    Ghosn, Mohamad G.
    Tuchin, Valery V.
    Larin, Kirill V.
    [J]. JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2010, 3 (03) : 169 - 176
  • [3] Assessment of tissue optical clearing as a function of glucose concentration using optical coherence tomography
    Sudheendran, Narendran
    Mohamed, Mohamed
    Ghosn, Mohamad G.
    Tuchin, Valery V.
    Larin, Kirill V.
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [4] Quantitative Assessment of Macroporous Cell Scaffold Structures using Optical Coherence Tomography (OCT)
    Paek, Andrew
    Betz, Martha W.
    Jiang, James
    Cable, Alex
    Fisher, John P.
    Chen, Yu
    [J]. 2009 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP, 2009, : 170 - +
  • [5] Feasibility study of normal and septic tracheal imaging using optical coherence tomography
    Jung, W
    Zhang, J
    Mina-Araghi, R
    Hanna, N
    Brenner, M
    Nelson, JS
    Chen, ZP
    [J]. LASERS IN SURGERY AND MEDICINE, 2004, 35 (02) : 121 - 127
  • [7] Non-destructive Characterization of Skeletal Muscle Extracellular Matrix Morphology by Combining Optical Coherence Tomography (OCT) Imaging with Tissue Clearing
    Maillet, Maxence
    Kammoun, Malek
    Avril, Stephane
    Tho, Marie-Christine Ho Ba
    Trabelsi, Olfa
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (10) : 2323 - 2336
  • [8] Non-destructive Characterization of Skeletal Muscle Extracellular Matrix Morphology by Combining Optical Coherence Tomography (OCT) Imaging with Tissue Clearing
    Maxence Maillet
    Malek Kammoun
    Stéphane Avril
    Marie-Christine Ho Ba Tho
    Olfa Trabelsi
    [J]. Annals of Biomedical Engineering, 2023, 51 : 2323 - 2336
  • [9] Mammalian Cochlear Hair Cell Imaging Using Optical Coherence Tomography (OCT): A Preliminary Study
    Choi, Sung-Won
    Kang, Jieun
    Lee, Seokhwan
    Oh, Se-Joon
    Kim, Hongki
    Kong, Soo-Keun
    [J]. JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2021, 17 (01): : 46 - 51
  • [10] Assessment of atherosclerotic plaque activity in patients with sleep apnea using hybrid positron emission tomography/magnetic resonance imaging (PET/MRI): a feasibility study
    Vaishnavi Kundel
    Maria Giovanna Trivieri
    Nicolas A. Karakatsanis
    Phillip M. Robson
    Venkatesh Mani
    Jorge R. Kizer
    Robert Kaplan
    Zahi Fayad
    Neomi Shah
    [J]. Sleep and Breathing, 2018, 22 : 1125 - 1135