Applicability of linear and nonlinear retention-time models for reversed-phase liquid chromatography separations of small molecules, peptides, and intact proteins

被引:26
|
作者
Tyteca, Eva [1 ]
De Vos, Jelle [1 ]
Vankova, Nikola [1 ,2 ]
Cesla, Petr [2 ]
Desmet, Gert [1 ]
Eeltink, Sebastiaan [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, Pleinlaan 2, B-1050 Brussels, Belgium
[2] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, Pardubice, Czech Republic
关键词
Linear solvent strength model; Method development; Neue-Kuss model; Retention-time prediction; Selectivity; SOLVENT-STRENGTH MODEL; GRADIENT-ELUTION; PREDICTION; OPTIMIZATION; PERFORMANCE; STRATEGIES; SELECTION; INSIGHTS; LIMITS;
D O I
10.1002/jssc.201501395
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The applicability and predictive properties of the linear solvent strength model and two non-linear retention-time models, i.e., the quadratic model and the Neue model, were assessed for the separation of small molecules (phenol derivatives), peptides, and intact proteins. Retention-time measurements were conducted in isocratic mode and gradient mode applying different gradient times and elution-strength combinations. The quadratic model provided the most accurate retention-factor predictions for small molecules (average absolute prediction error of 1.5%) and peptides separations (with a prediction error of 2.3%). An advantage of the Neue model is that it can provide accurate predictions based on only three gradient scouting runs, making tedious isocratic retention-time measurements obsolete. For peptides, the use of gradient scouting runs in combination with the Neue model resulted in better prediction errors (<2.2%) compared to the use of isocratic runs. The applicability of the quadratic model is limited due to a complex combination of error and exponential functions. For protein separations, only a small elution window could be applied, which is due to the strong effect of the content of organic modifier on retention. Hence, the linear retention-time behavior of intact proteins is well described by the linear solvent strength model. Prediction errors using gradient scouting runs were significantly lower (2.2%) than when using isocratic scouting runs (3.2%).
引用
收藏
页码:1249 / 1257
页数:9
相关论文
共 50 条
  • [1] RETENTION PREDICTION OF SMALL PEPTIDES IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    JINNO, K
    TANIGAWA, E
    CHROMATOGRAPHIA, 1988, 25 (07) : 613 - 617
  • [2] Retention time dataset for heterogeneous molecules in reversed-phase liquid chromatography
    Zhang, Yan
    Liu, Fei
    Li, Xiu Qin
    Gao, Yan
    Li, Kang Cong
    Zhang, Qing He
    SCIENTIFIC DATA, 2024, 11 (01)
  • [3] Retention times and bandwidths in reversed-phase gradient liquid chromatography of peptides and proteins
    Jandera, Pavel
    Kucerova, Zdenka
    Urban, Jiri
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (49) : 8874 - 8889
  • [4] Influence of Solvent Effects on Retention of Small Molecules in Reversed-Phase Liquid Chromatography
    Colin F. Poole
    Chromatographia, 2019, 82 : 49 - 64
  • [5] Influence of Solvent Effects on Retention of Small Molecules in Reversed-Phase Liquid Chromatography
    Poole, Colin F.
    CHROMATOGRAPHIA, 2019, 82 (01) : 49 - 64
  • [6] RETENTION MODEL FOR PROTEINS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    GENG, XD
    REGNIER, FE
    JOURNAL OF CHROMATOGRAPHY, 1984, 296 (JUL): : 15 - 30
  • [7] Comparison of selected retention models in reversed-phase liquid chromatography
    Ko, JJ
    Ford, JC
    JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) : 3 - 13
  • [8] Retention-time prediction for polycyclic aromatic compounds in reversed-phase capillary electro-chromatography
    Peter Feenstra
    Heidrun Gruber-Wölfler
    Michael Brunsteiner
    Johannes Khinast
    Journal of Molecular Modeling, 2015, 21
  • [9] Retention-time prediction for polycyclic aromatic compounds in reversed-phase capillary electro-chromatography
    Feenstra, Peter
    Gruber-Woelfler, Heidrun
    Brunsteiner, Michael
    Khinast, Johannes
    JOURNAL OF MOLECULAR MODELING, 2015, 21 (05)
  • [10] Application of reversed-phase liquid chromatography in separation and analysis of proteins and peptides
    Zhu, XN
    Su, ZG
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (02) : 248 - 254