Simultaneous voltammetric determination of guanine and adenine by using a glassy carbon electrode modified with a composite consisting of carbon quantum dots and overoxidized poly(2-aminopyridine)

被引:17
|
作者
He, Shaoying [1 ]
He, Ping [1 ,2 ]
Zhang, Xiaojuan [1 ]
Zhang, Xingquan [3 ]
Dong, Faqin [4 ]
Jia, Lingpu [1 ]
Du, Licheng [1 ]
Lei, Hong [1 ]
机构
[1] Southwest Univ Sci & Technol, Sch Mat Sci & Engn, Mianyang 621010, Sichuan, Peoples R China
[2] Mianyang Kingtiger New Energy Technol Co Ltd, Mianyang 621000, Sichuan, Peoples R China
[3] Southwest Univ Sci & Technol, Ctr Anal & Test, Mianyang 621010, Sichuan, Peoples R China
[4] Southwest Univ Sci & Technol, Key Lab Solid Waste Treatment & Resource Recycle, Minist Educ, Mianyang 621010, Sichuan, Peoples R China
关键词
Electrochemical polymerizantion; Nanomaterials; Electrocatalysis; Cyclic voltammetry; Differential pulse voltammetry; ASCORBIC-ACID; URIC-ACID; NANOPARTICLES; BIOSENSOR; DOPAMINE; IMMOBILIZATION; AMPLIFICATION; NANODOTS; PURINE;
D O I
10.1007/s00604-017-2636-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A composite consisting of carbon quantum dots (CQDs) and overoxidized poly(2-aminopyridine) (PAPox) was deposited on a glassy carbon electrode (GCE) through electrochemical polymerization and electrochemical oxidation. The modified GCE was used for the simultaneous determination of guanine and adenine. Electrochemical responses to guanine and adenine were investigated by cyclic voltammetry and differential pulse voltammetry. Owing to the synergistic effect of CQDs and PAPox, two oxidation peaks can be observed, with peaks at 0.81 and 1.13 V (vs. SCE) for guanine and adenine, respectively. The current at the respective peaks has a linear dependence on the concentrations of guanine in the range from 1.0 to 65 mu M, and of adenine in the range from 2.0 to 70 mu M. The respective detection limits are 0.51 and 0.39 mu M (at an S/N ratio of 3). The modified GCE is selective, reproducible and stable.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Simultaneous voltammetric determination of guanine and adenine by using a glassy carbon electrode modified with a composite consisting of carbon quantum dots and overoxidized poly(2-aminopyridine)
    Shaoying He
    Ping He
    Xiaojuan Zhang
    Xingquan Zhang
    Faqin Dong
    Lingpu Jia
    Licheng Du
    Hong Lei
    [J]. Microchimica Acta, 2018, 185
  • [2] A glassy carbon electrode modified with graphene quantum dots and silver nanoparticles for simultaneous determination of guanine and adenine
    Wang, Guoying
    Shi, Gaofeng
    Chen, Xuefu
    Yao, Ruixing
    Chen, Fuwen
    [J]. MICROCHIMICA ACTA, 2015, 182 (1-2) : 315 - 322
  • [3] A glassy carbon electrode modified with graphene quantum dots and silver nanoparticles for simultaneous determination of guanine and adenine
    Guoying Wang
    Gaofeng Shi
    Xuefu Chen
    Ruixing Yao
    Fuwen Chen
    [J]. Microchimica Acta, 2015, 182 : 315 - 322
  • [4] Poly(bromocresol green)/carbon quantum dots modified electrode for the simultaneous electrochemical determination of guanine and adenine
    He, Shaoying
    He, Ping
    Zhang, Xingquan
    Zhang, Xiaojuan
    Li, Caixia
    Dong, Faqin
    Lei, Hong
    Liu, Dechun
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 806 : 158 - 165
  • [5] A glassy carbon electrode modified with a nanocomposite consisting of carbon nanohorns and poly(2-aminopyridine) for non-enzymatic amperometric determination of hydrogen peroxide
    Jingchao Chen
    Ping He
    Hongmei Bai
    Hong Lei
    Guangli Zhang
    Faqin Dong
    Yongjun Ma
    [J]. Microchimica Acta, 2016, 183 : 3237 - 3242
  • [6] A glassy carbon electrode modified with a nanocomposite consisting of carbon nanohorns and poly(2-aminopyridine) for non-enzymatic amperometric determination of hydrogen peroxide
    Chen, Jingchao
    He, Ping
    Bai, Hongmei
    Lei, Hong
    Zhang, Guangli
    Dong, Faqin
    Ma, Yongjun
    [J]. MICROCHIMICA ACTA, 2016, 183 (12) : 3237 - 3242
  • [7] A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    [J]. MICROCHIMICA ACTA, 2016, 183 (07) : 2317 - 2325
  • [8] A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine
    Biuck Habibi
    Mojtaba Jahanbakhshi
    [J]. Microchimica Acta, 2016, 183 : 2317 - 2325
  • [9] Voltammetric Determination of Sumatriptan by an Overoxidized Poly(p-aminophenol) Modified Glassy Carbon Electrode
    Jalali-Sarvestani, Mohammad Reza
    Madrakian, Tayyebeh
    Afkhami, Abbas
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2021, 8 (03): : 245 - 259
  • [10] A glassy carbon electrode modified with electrochemically reduced graphene for simultaneous determination of guanine and adenine
    Zhu, Xiaohua
    Zeng, Lixuan
    Xu, Maotian
    Liang, Yong
    Nan, Junmin
    [J]. ANALYTICAL METHODS, 2012, 4 (09) : 2935 - 2939