Effect of bonded length on the load response and failure mode of pull-out tests of GFRP bars embedded in concrete

被引:14
|
作者
Zhao, Xudong [1 ]
Rahman, Mohammod Minhajur [1 ]
D'Antino, Tommaso [2 ]
Focacci, Francesco [3 ]
Carloni, Christian [1 ]
机构
[1] Case Western Reserve Univ, Dept Civil & Environm Engn, Cleveland, OH 44106 USA
[2] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Milan, Italy
[3] eCampus Univ, Novedrate, Italy
关键词
Glass fiber reinforced polymer (GFRP); Bonded length; Pull-out tests; REINFORCED POLYMER BARS; BEHAVIOR; GLASS; STRENGTH; CRACKING; PERFORMANCE; STRESS; BEAMS;
D O I
10.1016/j.conbuildmat.2022.128425
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the experimental results of pull-out tests of glass fiber-reinforced polymer (GFRP) bars embedded in concrete are presented and discussed. The experimental work is designed to investigate the effect of the bonded length on the bond behavior of the bars. Five bonded lengths are considered. The first bonded length is equal to 5 times the bar diameter (db), which is the bonded length recommended in ASTM D7913. The other four bonded lengths are equal to 10db, 20db, 30db, and 40db. Loaded-end displacement is obtained from the measurements of three linear variable displacement transformers (LVDTs). Pull-out tests are performed in displacement control. For some specimens, the free-end displacement is measured by two additional LVDTs. The load responses in terms of applied load versus machine stroke, loaded-end slip, and free-end slip are plotted and compared for the different bonded lengths. The average shear stress is plotted versus the bonded length. Finally, the maximum axial stress in pull-out tests is plotted versus the bonded length and compared with the prediction of ACI 440.1R-15.
引用
收藏
页数:18
相关论文
共 43 条
  • [1] The bonding strength of GFRP bars embedded within concrete under direct pull-out test
    Kusnadi
    Djamaluddin, R.
    Muhiddin, B.
    Irmawaty, R.
    3RD INTERNATIONAL CONFERENCE ON CIVIL AND ENVIRONMENTAL ENGINEERING (ICCEE 2019), 2020, 419
  • [2] Pull-out tests of ribbed steel reinforcing bars embedded in concrete with steel fibres
    Lukanu Lwa Nzambi, Aaron Kadima
    Carvalho de Oliveira, Denio Ramam
    de Oliveira, Andrielli Morais
    Picanco, Marcelo de Souza
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2021, 174 (03) : 181 - 189
  • [3] Pull-out strength of bars embedded in high performance concrete
    Hamouine, A
    Lorrain, M
    MATERIALS AND STRUCTURES, 1995, 28 (184): : 569 - 574
  • [4] Assessing the embedded length of epoxy-bonded carbon laminates by pull-out bending tests
    Cruz, JMS
    Barros, JAO
    Faria, R
    COMPOSITES IN CONSTRUCTION, 2001, : 217 - 222
  • [5] Fatigue pull-out failure of deformed bars in concrete under the effect of liquid water
    Matsumoto, Koji
    Yamaguchi, Hirofumi
    Nagai, Kohei
    CEMENT & CONCRETE COMPOSITES, 2018, 91 : 198 - 208
  • [6] Size effect on the concrete cone pull-out load
    J. Ožbolt
    R. Elighausen
    H.W. Reinhardt
    International Journal of Fracture, 1999, 95 : 391 - 404
  • [7] Pull-out bond efficiency and load capacity of the bonded HSC strips reinforced with steel and FRP bars to concrete
    Seleem, M. H.
    Megahed, F. A.
    Badawy, A. A. M.
    Sharaky, I. A.
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2025, 22
  • [8] Size effect on the concrete cone pull-out load
    Ozbolt, J
    Eligehausen, R
    Reinhardt, HW
    INTERNATIONAL JOURNAL OF FRACTURE, 1999, 95 (1-4) : 391 - 404
  • [9] Pull-out tests of deformed bars from ferrous mill tailing concrete
    Zheng, Yan
    Kang, Hongzhen
    Wang, Guangqi
    APPLIED MECHANICS AND MATERIALS II, PTS 1 AND 2, 2014, 477-478 : 697 - +
  • [10] Bond-Slip Behavior Between GFRP Bars and Mortar Based on Pull-Out Tests
    Jin, Qingping
    Wang, Guangbo
    Liang, Tingying
    Chen, Peixia
    POLYMER COMPOSITES, 2019, 40 (07) : 2840 - 2849