Biomechanical comparison of osteosynthesis with poly-L-lactic acid and titanium screw in intracapsular condylar fracture fixation: An experimental study

被引:9
|
作者
Omezli, M. M. [1 ]
Torul, D. [2 ]
Polat, M. E. [3 ]
Dayi, E. [3 ]
机构
[1] Ordu Univ, Dept Oral & Maxillofacial Surg, Fac Dent, TR-52100 Ordu, Turkey
[2] Ondokuz Mayis Univ, Dept Oral & Maxillofacial Surg, Fac Dent, TR-55100 Samsun, Turkey
[3] Ataturk Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-25240 Erzurum, Turkey
关键词
Intracapsular condylar fractures; osteosynthesis; screw fixation; MANDIBULAR CONDYLE; RESORBABLE PINS; DIACAPITULAR FRACTURES; IN-VITRO; SHEEP; HEAD; RESISTANCE; REDUCTION; PLATES;
D O I
10.4103/1119-3077.158946
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Aims: The aim of this study was to compare the biomechanical stability of poly-L-lactic acid and titanium screws in the fixation of intracapsular condylar fractures, in 10 polyurethane hemimandibles. Materials and Methods: Artificial intracapsular fractures were created with a steel disk and electronic micromotor. The first group was fixed with 15 mm long self-tapping 2.0 mm system titanium screws and the second group was fixed with 15 mm long 2.4 mm bioresorbable screws. Linear loads of 25, 50, 75, 100 N was applied in anteroposterior direction to the hemimandibles and the data were transmitted directly from the load cell to a computer that shows emergent results of material characteristics under same forces as a graphic containing force and displacement. Results: The results show that there were no significant differences between the two methods, with 25 N of loading. (P > 0,05) The difference became significant with a higher value of loading. Conclusion: The results suggest that treatment with a single resorbable screw is not functionally stable as a single titanium screw.
引用
收藏
页码:589 / 593
页数:5
相关论文
共 50 条
  • [1] Biomechanical Comparison of Titanium and Poly-L-Lactic Acid Trapezoidal Plates Applied in a Subcondylar Fracture Model
    Keskin Yalcin, Basak
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (06) : 1737 - 1740
  • [2] Biomechanical Loading Comparison between Titanium and Bioactive Resorbable Screw Systems for Fixation of Intracapsular Condylar Head Fractures
    Sukegawa, Shintaro
    Yamamoto, Norio
    Nakano, Keisuke
    Takabatake, Kiyofumi
    Kawai, Hotaka
    Kanno, Takahiro
    Nagatsuka, Hitoshi
    Furuki, Yoshihiko
    MATERIALS, 2020, 13 (14)
  • [3] Comparing maximal forces in resorbable poly-L-lactic acid and titanium plates for mandibular fracture fixation
    Burns, Brady
    Fields, Joseph-Michael
    Farinas, Angel
    Pollins, Alonda
    Perdikis, Galen
    Thayer, Wesley
    HELIYON, 2020, 6 (04)
  • [4] Complications of a poly-l-lactic acid and polyglycolic acid osteosynthesis device for internal fixation in maxillofacial surgery
    Sukegawa, Shintaro
    Kanno, Takahiro
    Matsumoto, Kenichi
    Sukegawa-Takahashi, Yuka
    Masui, Masanori
    Furuki, Yoshihiko
    ODONTOLOGY, 2018, 106 (04) : 360 - 368
  • [5] Complications of a poly-l-lactic acid and polyglycolic acid osteosynthesis device for internal fixation in maxillofacial surgery
    Shintaro Sukegawa
    Takahiro Kanno
    Kenichi Matsumoto
    Yuka Sukegawa-Takahashi
    Masanori Masui
    Yoshihiko Furuki
    Odontology, 2018, 106 : 360 - 368
  • [6] MRI study of bioabsorbable poly-L-lactic acid devices used for fixation of fracture and osteotomies
    Marumo, K
    Sato, Y
    Suzuki, H
    Kurosaka, D
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (02) : 154 - 158
  • [7] Biomechanical analysis of poly-L-lactic acid and titanium plates fixated for mandibular symphyseal fracture with a conservatively treated unilateral condylar fracture using the three-dimensional finite element method
    Murakami, Kazuhiro
    Yamamoto, Kazuhiko
    Sugiura, Tsutomu
    Kawakami, Masayoshi
    Horita, Satoshi
    Kirita, Tadaaki
    DENTAL TRAUMATOLOGY, 2015, 31 (05) : 396 - 402
  • [8] FIXATION OF SUBCAPITAL FEMORAL OSTEOTOMIES BY POLY-L-LACTIC ACID PINS - AN EXPERIMENTAL-STUDY IN SHEEP
    VASENIUS, J
    LAITINEN, O
    POHJONEN, T
    VAINIONPAA, S
    TORMALA, P
    ROKKANEN, P
    INTERNATIONAL ORTHOPAEDICS, 1993, 17 (03) : 144 - 147
  • [9] Influence of Temperature on the Biomechanical Stability of Titanium, PEEK, Poly-L-Lactic Acid, and β-Tricalcium Phosphate Poly-L-Lactic Acid Suture Anchors Tested on Human Humeri In Vitro in a Wet Environment
    Guelecyuez, Mehmet F.
    Mazur, Alexandra
    Schroeder, Christian
    Braun, Christian
    Ficklscherer, Andreas
    Rossbach, Bjoern P.
    Mueller, Peter E.
    Pietschmann, Matthias F.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (06): : 1134 - 1141
  • [10] Changes in condylar long axis and skeletal stability after bilateral sagittal split ramus osteotomy with poly-L-lactic acid or titanium plate fixation
    Ueki, K
    Nakagawa, K
    Marukawa, K
    Takazakura, D
    Shimada, M
    Takatsuka, S
    Yamamoto, E
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (06) : 627 - 634