On-chip electrical detection of parallel loop-mediated isothermal amplification with DG-BioFETs for the detection of foodborne bacterial pathogens

被引:17
|
作者
Duarte-Guevara, Carlos [1 ,2 ]
Swaminathan, Vikhram V. [2 ]
Reddy, Bobby, Jr. [2 ]
Huang, Jui-Cheng [3 ]
Liu, Yi-Shao [4 ]
Bashir, Rashid [5 ]
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[3] Taiwan Semicond Mfg Co, Design & Technol Platform, Hsinchu, Taiwan
[4] Delta Elect Inc, Res & Ecosyst, Singapore 417939, Singapore
[5] Univ Illinois, Dept Bioengn, Urbana, IL 61802 USA
关键词
ESCHERICHIA-COLI; RAPID DETECTION; FOOD SAFETY; DEVICES; BEEF; TRANSISTORS; STANDARDS; QUALITY; SENSOR; PANEL;
D O I
10.1039/c6ra19685c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The use of field effect transistors (FETs) as the transduction element for the detection of DNA amplification reactions will enable portable and inexpensive nucleic acid analysis. Transistors used as biological sensors, or BioFETs, minimize the cost and size of detection platforms by leveraging fabrication methods already well developed for electronics. Here, we report a dual-gate BioFET (DG-BioFET) array platform with 1024 x 1024 sensors that is used for on-chip electrical detection of loop-mediated isothermal amplification (LAMP) reactions that target food borne bacterial pathogens. The DG-BioFETs of our 7 x 7 mm 2 array are able to electrically detect pH changes that are triggered by nucleotide incorporation during LAMP elongation. Multiple 250 nL reactions can be simultaneously electrically monitored in our array that is divided in 30 micro-chambers with gold-coated anisotropically etched silicon wells that act both as reference electrode and confinement element. Our characterization results show that the goldbiased DG-BioFETs have a sensitivity of 32 mV pH(-1) (equivalent to 2 mA pH(-1)) and an average resolution of 0.5 pH units. This sensitivity is high enough to detect the pH changes triggered by the amplification reaction, but to maximize our signal-to-noise ratio and improve our quantitative conclusions we use a group of data analysis techniques that are available in our high-density platform that monitors each reaction with similar to 3500 independent BioFETs. We use redundancy techniques to minimize the overall standard deviation of our measurements, the Grubbs test to eliminate measurements outside the expected normal distribution, and reference micro-chambers to subtract the common noise. With these techniques we are capable of reducing the P value, of a t-test comparing positive and negative readings, from a typical 0.17 to 0.03. The platform that we present along with the analysis techniques that we developed allow the on-chip electrical detection and identification of E. coli O157 and S. typhi with parallel LAMP assays targeting eae and invA genes. The LAMP reactions are highly specific, without false positives, and our titration assays demonstrate a limit of detection of 23 CFU per reaction on chip.
引用
收藏
页码:103872 / 103887
页数:16
相关论文
共 50 条
  • [1] On-chip parallel detection of foodborne pathogens using loop-mediated isothermal amplification
    Duarte, Carlos
    Salm, Eric
    Dorvel, Brian
    Reddy, Bobby, Jr.
    Bashir, Rashid
    BIOMEDICAL MICRODEVICES, 2013, 15 (05) : 821 - 830
  • [2] On-chip parallel detection of foodborne pathogens using loop-mediated isothermal amplification
    Carlos Duarte
    Eric Salm
    Brian Dorvel
    Bobby Reddy
    Rashid Bashir
    Biomedical Microdevices, 2013, 15 : 821 - 830
  • [3] Multiplex detection of foodborne pathogens by real-time loop-mediated isothermal amplification on a digital microfluidic chip
    Xie, Mei
    Chen, Tianlan
    Xin, Xiong
    Cai, Zongwei
    Dong, Cheng
    Lei, Bo
    FOOD CONTROL, 2022, 136
  • [4] Picoinjection-Enabled Multitarget Loop-Mediated Isothermal Amplification for Detection of Foodborne Pathogens
    Yuan, Hao
    Chao, Youchuang
    Li, ShanShan
    Tang, Matthew Y. H.
    Huang, Yue
    Che, You
    Wong, Alice S. T.
    Zhang, Tong
    Shum, Ho Cheung
    ANALYTICAL CHEMISTRY, 2018, 90 (22) : 13173 - 13177
  • [5] SENSITIVE AND SPECIFIC DETECTION OF FOODBORNE PATHOGENS IN PORK BY A LOOP-MEDIATED ISOTHERMAL AMPLIFICATION METHODOLOGY
    Xiong, Zhiyong
    Zhang, Junping
    Kang, Min
    ACTA MEDICA MEDITERRANEA, 2016, 32 : 1143 - 1147
  • [6] Evaluating Commercial Loop-Mediated Isothermal Amplification Master Mixes for Enhanced Detection of Foodborne Pathogens
    Costa-Ribeiro, Ana
    Lamas, Alexandre
    Garrido-Maestu, Alejandro
    FOODS, 2024, 13 (11)
  • [7] Detection of bovine mastitis pathogens by loop-mediated isothermal amplification and an electrochemical DNA chip
    Kawai, Kazuhiro
    Inada, Mika
    Ito, Keiko
    Hashimoto, Koji
    Nikaido, Masaru
    Hata, Eiji
    Katsuda, Ken
    Kiku, Yoshio
    Tagawa, Yuichi
    Hayashi, Tomohito
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2017, 79 (12): : 1973 - 1977
  • [8] Application of loop-mediated isothermal amplification on pathogens rapid detection
    Li, B., 1600, South China University of Technology (30):
  • [9] Ultrafast bacterial cell lysis using a handheld corona treater and loop-mediated isothermal amplification for rapid detection of foodborne pathogens
    Li, Mengzhe
    Luan, Zhixian
    Liu, Yongxiang
    Yang, Chen
    Wang, Yanling
    Ma, Cuiping
    Shi, Chao
    FOOD CONTROL, 2021, 128
  • [10] A loop-mediated isothermal amplification-based microfluidic chip for triplex detection of shrimp pathogens
    Hu, Keshun
    Li, Ye
    Wang, Feng
    Liu, Jianying
    Li, Yuanyuan
    Zhao, Qian
    Zheng, Xiaoye
    Zhu, Ningyu
    Yu, Xiaoping
    Fang, Shaohua
    Huang, Jun
    JOURNAL OF FISH DISEASES, 2023, 46 (02) : 137 - 146