Inverse field-based approach for simultaneous B1 mapping at high fields - A phantom based study

被引:8
|
作者
Jin, Jin [1 ]
Liu, Feng [1 ]
Zuo, Zhentao [2 ]
Xue, Rong [2 ]
Li, Mingyan [1 ]
Li, Yu [1 ]
Weber, Ewald [1 ]
Crozier, Stuart [1 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
[2] Chinese Acad Sci, Inst Biophys, State Key Lab Brain & Cognit Sci, Beijing MRI Ctr Brain Res, Beijing 100080, Peoples R China
关键词
Transmit sensitivity mapping; Receive sensitivity (receptivity) mapping; B-1; Inverse method; Field-based approach; Signal intensity; Parallel imaging; SENSE; Iterative optimization; Method of moments (MoM); PARALLEL MRI; 7; T; SENSITIVITY; RECONSTRUCTION; COIL; INHOMOGENEITY; EXCITATION; LOSSY; ARRAY;
D O I
10.1016/j.jmr.2012.02.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Based on computational electromagnetics and multi-level optimization, an inverse approach of attaining accurate mapping of both transmit and receive sensitivity of radiofrequency coils is presented. This paper extends our previous study of inverse methods of receptivity mapping at low fields, to allow accurate mapping of RF magnetic fields (B-1) for high-field applications. Accurate receive sensitivity mapping is essential to image domain parallel imaging methods, such as sensitivity encoding (SENSE), to reconstruct high quality images. Accurate transmit sensitivity mapping will facilitate RF-shimming and parallel transmission techniques that directly address the RF inhomogeneity issue, arguably the most challenging issue of high-field magnetic resonance imaging (MRI). The inverse field-based approach proposed herein is based on computational electromagnetics and iterative optimization. It fits an experimental image to the numerically calculated signal intensity by iteratively optimizing the coil-subject geometry to better resemble the experiments. Accurate transmit and receive sensitivities are derived as intermediate results of the optimization process. The method is validated by imaging studies using homogeneous saline phantom at 7T. A simulation study at 300 MHz demonstrates that the proposed method is able to obtain receptivity mapping with errors an order of magnitude less than that of the conventional method. The more accurate receptivity mapping and simultaneously obtained transmit sensitivity mapping could enable artefact-reduced and intensity-corrected image reconstructions. It is hoped that by providing an approach to the accurate mapping of both transmit and receive sensitivity, the proposed method will facilitate a range of applications in high-field MRI and parallel imaging. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:27 / 35
页数:9
相关论文
共 50 条
  • [1] A Field-Based Approach To Teach Geoscience: A Study With Secondary Students
    Esteves, Helena
    Fernandes, Isabel
    Vasconcelos, Clara
    [J]. Proceedings of 6th World Conference on Educational Sciences, 2015, 191 : 63 - 67
  • [2] An antibody-based microarray assay for the simultaneous detection of aflatoxin B1 and fumonisin B1
    Lamberti I.
    Tanzarella C.
    Solinas I.
    Padula C.
    Mosiello L.
    [J]. Mycotoxin Research, 2009, 25 (4) : 193 - 200
  • [3] A theoretical and experimental comparison of different techniques for B1 mapping at very high fields
    Pohmann, Rolf
    Scheffler, Klaus
    [J]. NMR IN BIOMEDICINE, 2013, 26 (03) : 265 - 275
  • [4] TROMBONE: T1-Relaxation-Oblivious Mapping of Transmit Radio-Frequency Field (B1) for MRI at High Magnetic Fields
    Fleysher, Roman
    Fleysher, Lazar
    Inglese, Matilde
    Sodickson, Daniel
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 483 - 491
  • [5] Mapping the B1 field distribution with nonideal gradients in a high-resolution NMR spectrometer
    Jerschow, A
    Bodenhausen, G
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) : 108 - 115
  • [6] TriTone:: a radiofrequency field (B1)-insensitive T1 estimator for MRI at high magnetic fields
    Fleysher, Roman
    Fleysher, Lazar
    Liu, Songtao
    Gonen, Oded
    [J]. MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 781 - 789
  • [7] Simultaneous mapping of water shift and B1(WASABI)Application to field-Inhomogeneity correction of CEST MRI data
    Schuenke, Patrick
    Windschuh, Johannes
    Roeloffs, Volkert
    Ladd, Mark E.
    Bachert, Peter
    Zaiss, Moritz
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 571 - 580
  • [8] An inverse methodology for high-frequency RF coil design for MRI with de-emphasized B1 fields
    Xu, B
    Wei, Q
    Liu, F
    Crozier, S
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (09) : 1582 - 1587
  • [9] Multiplex bio-barcode based fluorometric immunoassay for simultaneous determination of zearalenone, fumonisin B1, ochratoxin A, and aflatoxin B1 in cereals
    Huang, Na
    Sheng, Wei
    Bai, Dongmei
    Sun, Meiyi
    Ren, Lishuai
    Wang, Shuo
    Zhang, Wanli
    Jin, Zixin
    [J]. FOOD CONTROL, 2023, 150
  • [10] Inverse scattering approach based on the field equivalence principle: inversion without a priori information on incident fields
    Takenaka, Takashi
    Moriyama, Toshifumi
    [J]. OPTICS LETTERS, 2012, 37 (16) : 3432 - 3434