Sweep voltammetry with a semi-circular potential waveform: Electrode kinetics

被引:13
|
作者
Uchida, Yuki [1 ]
Katelhon, Enno [1 ]
Compton, Richard G. [1 ]
机构
[1] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, South Parks Rd, Oxford OX1 3QZ, England
基金
欧洲研究理事会;
关键词
Linear sweep voltammetry; Microdisc electrode; Semi-circular potential waveform; Electrochemical rate constant determination; CYCLIC VOLTAMMETRY; MICROELECTRODES; DIFFUSION;
D O I
10.1016/j.jelechem.2018.12.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We introduce a sensitive, novel way to determine the standard electrochemical rate constant, k(o), through the application of a semi-circular potential wave at a microdisc electrode. A one-electron reduction reaction is investigated and simulated for varying rate constants. It is shown that the voltammograms of a semi-circular potential wave exhibit significantly greater sensitivity to the changes in electrode kinetics compared to the conventional linear potential wave. A reprogramming of a commercial potentiostat can yield a one order magnitude greater sensitivity and can be used to determine the rate constant of a system under investigation.
引用
收藏
页码:60 / 66
页数:7
相关论文
共 50 条
  • [1] Semi-Circular Potential Sweep Voltammetry: Electrochemically Quasi-Reversible System
    Park, Kyungsoon
    Hwang, Seongpil
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2020, 11 (04) : 379 - 383
  • [2] Semi-circular potential sweep voltammetry: Experimental verification and determination of the formal potential of a reversible redox couple
    Amin, Hatem M. A.
    Uchida, Yuki
    Katelhon, Enno
    Compton, Richard G.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 836 : 62 - 67
  • [3] Semi-circular sweep voltammetry. Bio-analytical applications
    Wang, Yuanzhe
    Compton, Richard G.
    BIOSENSORS & BIOELECTRONICS, 2021, 179 (179):
  • [4] Stripping voltammetry with semi-circular potential waves: Reversible systems
    Uchida, Yuki
    Katelhon, Enno
    Compton, Richard G.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 848
  • [5] Determination of standard electrochemical rate constants from semi-circular sweep voltammetry: A combined theoretical and experimental study
    Amin, Hatem M. A.
    Uchida, Yuki
    Katelhon, Enno
    Compton, Richard G.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 880 (880)
  • [6] Posterior semi-circular canal electrode misplacement in Goldenhar's syndrome
    Castellino, Ashish
    Rayamajhi, Pabina
    Kurkure, Rahul
    Kameswaran, Mohan
    COCHLEAR IMPLANTS INTERNATIONAL, 2021, 22 (01) : 56 - 60
  • [7] THE APPLICATION OF CONVOLUTION POTENTIAL SWEEP VOLTAMMETRY AT A ROTATING-DISK ELECTRODE TO SIMPLE ELECTRON-TRANSFER KINETICS
    VALDES, JL
    CHEH, HY
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 181 (1-2): : 65 - 81
  • [8] POTENTIAL-SWEEP VOLTAMMETRY - ADSORPTION OF CHLORANILIC ACID ON A MERCURY ELECTRODE
    ROFFIA, S
    VIANELLO, E
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1967, 15 (04): : 405 - &
  • [9] LINEAR SWEEP VOLTAMMETRY AT THE TUBULAR ELECTRODE
    DUTT, J
    SINGH, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 182 (02) : 259 - 266
  • [10] NORMALIZED POTENTIAL SWEEP VOLTAMMETRY .1. APPLICATION TO ELECTRODE MECHANISM ANALYSIS
    AALSTAD, B
    PARKER, VD
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 122 (MAY): : 183 - 193