The Boltzmann constant has been determined by performing isotherm measurements around the triple point of neon with dielectric-constant gas thermometry (DCGT). The necessary thermodynamic reference has been established with an uncertainty of about two tenths of a millikelvin, via realizing the International Temperature Scale of 1990, ITS-90, and exploiting the recently published results for the deviation between thermodynamic temperature and the ITS-90. In combination with a detailed treatment of uncertainty estimates and correlations, a value for the Boltzmann constant of k(LT) = 1.380 657 x 10(-23) JK(-1) with a standard uncertainty of 15.9 parts per million (ppm) has been determined. This value deviates from the CODATA value, published in 2008, by only 4.7 ppm and is in very good agreement with the value obtained by DCGT at the triple point of water k(TPW) = 1.380 654 x 10(-23) JK(-1) with an uncertainty of 9.2 ppm. The weighted mean of k(LT) and k(TPW) leads to the DCGT estimate for the Boltzmann constant of k = 1.380 655 x 10(-23) JK(-1) with an uncertainty of 7.9 ppm.
引用
收藏
页码:L4 / L7
页数:4
相关论文
共 50 条
  • [1] Determination of the Boltzmann constant by dielectric-constant gas thermometry
    Fellmuth, Bernd
    Fischer, Joachim
    Gaiser, Christof
    Jusko, Otto
    Priruenrom, Tasanee
    Sabuga, Wladimir
    Zandt, Thorsten
    METROLOGIA, 2011, 48 (05) : 382 - 390
  • [2] Improved determination of the Boltzmann constant by dielectric-constant gas thermometry
    Gaiser, Christof
    Zandt, Thorsten
    Fellmuth, Bernd
    Fischer, Joachim
    Jusko, Otto
    Sabuga, Wladimir
    METROLOGIA, 2013, 50 (06) : L7 - L11
  • [3] Dielectric-Constant Gas-Thermometry Measuring System for the Determination of the Boltzmann Constant at PTB
    T. Zandt
    B. Fellmuth
    C. Gaiser
    A. Kuhn
    International Journal of Thermophysics, 2010, 31 : 1371 - 1385
  • [4] Dielectric-Constant Gas-Thermometry Measuring System for the Determination of the Boltzmann Constant at PTB
    Zandt, T.
    Fellmuth, B.
    Gaiser, C.
    Kuhn, A.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2010, 31 (07) : 1371 - 1385
  • [5] Dielectric-constant gas thermometry
    Gaiser, Christof
    Zandt, Thorsten
    Fellmuth, Bernd
    METROLOGIA, 2015, 52 (05) : S217 - S226
  • [6] Final determination of the Boltzmann constant by dielectric- constant gas thermometry
    Gaiser, Christof
    Fellmuth, Bernd
    Haft, Norbert
    Kuhn, Axel
    Thiele-Krivoi, Bettina
    Zandt, Thorsten
    Fischer, Joachim
    Jusko, Otto
    Sabuga, Wladimir
    METROLOGIA, 2017, 54 (03) : 280 - 289
  • [7] DIELECTRIC-CONSTANT OF COMPRESSED SOLID METHANE AT LOW-TEMPERATURE
    COSTANTINO, MS
    DANIELS, WB
    JOURNAL OF CHEMICAL PHYSICS, 1975, 62 (03): : 764 - 770
  • [8] MICROWAVE DIELECTRIC-CONSTANT OF A LOW-TEMPERATURE COFIRED CERAMIC
    GIPPRICH, JW
    LEAHY, KA
    MARTIN, AJ
    RICH, EL
    SPARKS, KW
    IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1991, 14 (04): : 732 - 737
  • [9] Dielectric-Constant Gas Thermometry and the Relation to the Virial Coefficients
    Gaiser, C.
    Fellmuth, B.
    Zandt, T.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (3-4) : 395 - 404
  • [10] Dielectric-Constant Gas Thermometry and the Relation to the Virial Coefficients
    C. Gaiser
    B. Fellmuth
    T. Zandt
    International Journal of Thermophysics, 2014, 35 : 395 - 404