In-situ pathlength calibration of integrating spheres used in measurement of absorbance

被引:0
|
作者
Hodgkinson, J. [1 ]
Bergin, S. [1 ]
Francis, D. [1 ]
Masiyano, D. [1 ]
Davis, N. M. [1 ]
Staines, S. E. [1 ]
Tatam, R. P. [1 ]
机构
[1] Cranfield Univ, Engn Photon, Cranfield MK43 0AL, Beds, England
来源
OPTICAL SENSING AND DETECTION V | 2018年 / 10680卷
基金
英国工程与自然科学研究理事会;
关键词
Integrating sphere; tunable diode laser spectroscopy; TDLS; multipass cells; methane detection; pathlength calibration; ABSORPTION CELLS; SPECTROSCOPY; SPECKLE;
D O I
10.1117/12.2306655
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
When used as samples cells for optical absorbance measurements, integrating spheres offer increased pathlengths compared to single pass cells combined with tolerance to misalignment. This makes them attractive during alignment of optical instruments and in challenging environments subject to vibration. However, integrating spheres can suffer problems when used in sensitive and / or accurate absorbance measurement. We present our work to date to address these issues in high resolution laser spectroscopy. Firstly, optical interference effects include both random laser speckle and structured interference fringes created by optical feedback to the laser. Secondly, the sphere's optical pathlength is a combination of multiple paths that take an exponential pathlength distribution. At low values of absorbance, the measured signal is linear with concentration, but at higher absorbances signals follow a nonlinear but predictable function of absorbance. Thirdly, our most recent work concerns calibration of the optical pathlength, which is a sensitive function of its internal reflectivity. In-situ calibration is needed if the sphere is to be used in dirty environments or with condensing samples. Measurements from multiple independent sources and / or detectors are combined to provide compensation from fouling of the sphere walls and windows. Results are presented for an integrating sphere used in the measurement of methane. The emission from a tunable DFB laser at 1651nm was tuned across the gas absorption line to measure its concentration. Reduced sphere reflectivity was simulated by applying small areas of black tape on the inner surface. Finally, we give an example of one application where our results are being put into practice: use of an integrating sphere with a tunable laser at 3.3 mu m to measure atmospheric methane, installed on a two seater light aircraft.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A method for continuous in-situ pathlength calibration of integrating sphere based gas cells
    Bergin, S.
    Hodgkinson, J.
    Francis, D.
    Tatam, R. P.
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES XII, 2015, 9486
  • [2] In-Situ pH Measurement And Real-Time Calibration
    Tan, Chunyang
    Ding, Kang
    Seyfried, William E., Jr.
    SEA TECHNOLOGY, 2014, 55 (06) : 41 - 44
  • [3] Ratiometric pathlength calibration of integrating sphere-based absorption cells
    Bergin, S.
    Hodgkinson, J.
    Francis, D.
    Tatam, R. P.
    OPTICS EXPRESS, 2020, 28 (13) : 19574 - 19592
  • [4] Development of relative radiometric calibration system for in-situ measurement spectroradiometers
    Oh, Eunsong
    Ahn, Ki-Beom
    Kang, Hyukmo
    Cho, Seong-Ick
    Park, Young-Je
    KOREAN JOURNAL OF REMOTE SENSING, 2014, 30 (04) : 455 - 464
  • [5] Measurement of Henry's law constants using a new in-situ optical absorbance method
    Allen, JM
    Ramachandran, BR
    Balcalage, WX
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 156 - ENVR
  • [6] IN-SITU THICKNESS CALIBRATION OF THIN TARGETS USED IN THE DETERMINATION OF STOPPING POWER
    UNTER, E
    EPPACHER, C
    SEMRAD, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 83 (04): : 577 - 580
  • [7] LONG PATHLENGTH ULTRAVIOLET ABSORBANCE DETECTION FOR GAS-CHROMATOGRAPHY WITH CONCURRENT FLUORESCENCE MEASUREMENT
    VANENGELEN, DL
    ADAMS, AK
    THOMAS, LC
    JOURNAL OF CHROMATOGRAPHY, 1985, 331 (01): : 77 - 82
  • [8] Autonomous in-situ analysis of the upper ocean -: Construction of a compact, long pathlength absorbance spectrometer aimed at order-of-magnitude improvements in the sensitivity of spectrophotometric analysis
    Byrne, R
    Kaltenbacher, E
    Waterbury, R
    SEA TECHNOLOGY, 1999, 40 (02) : 71 - +
  • [9] Estimating uncertainty of flow measurement for the in-situ calibration of large water meters
    Johnson, E. H.
    AUSTRALASIAN JOURNAL OF WATER RESOURCES, 2007, 11 (01): : 41 - 52
  • [10] Establishment of absolute measurement standards for in-situ calibration of acoustic emission energy
    Yan, T
    Jones, BE
    MEASUREMENT & CONTROL, 2001, 34 (10): : 300 - 305