Evaluation of Upper Limb Muscle Activation Using Musculoskeletal Model with Wearable Assistive Device

被引:2
|
作者
Ashari, M. F. [1 ]
Hanafusa, A. [1 ]
Mohamaddan, S. [1 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Saitama, 3378570, Japan
关键词
UPPER EXTREMITY; REHABILITATION; THERAPY; STROKE;
D O I
10.1155/2022/8908061
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent years, wearable assistive device has been used to support upper arm movement training for rehabilitation purposes. A wearable assistive device could affect the muscle output during motor tasks to support upper limb disorder rehabilitation training. However, the investigation of muscle activity with the given assistive force is not widely investigated. In this study, the evaluation of upper limb muscle activities using musculoskeletal simulation systems with the developed wearable cable-driven assistive device has been carried out. An experimental protocol consisting of a series of motions was executed with five healthy subjects. Muscle activation on the brachioradialis, biceps, and triceps muscles was measured by using surface electromyography (EMG) and analyzed. The simulations with a musculoskeletal model to estimate muscle output with and without a wearable assistive device were performed for three tasks. An assistive upper arm device was integrated into the musculoskeletal model, and the desired assistive force is translated to the arm joint along with a tendon routing structure. Assisting movement by the wearable device was evaluated by measuring muscle activation with-assist and without-assist conditions. The results show that the use of the wearable assistive device can effectively assist in arm movement. Comparisons of measured EMG muscle data and the musculoskeletal model revealed that muscle force was generated throughout the arm. The integrated musculoskeletal model results show that muscle force values for two primary muscles (biceps and brachioradialis) were reduced during the simulated task when wearing the assistive device. These results are congruent with expectations, with the assistive device that supports the upper limb movement, providing practical assistance. The results highlight the importance of evaluating muscle output for the developed wearable assistive device to support the assistive movement. Lastly, the musculoskeletal simulation system could reduce the resource-intensive, and time consumed with the experimental testing could be achieved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] ForceArm: A Wearable Pneumatic Gel Muscle (PGM)-Based Assistive Suit for the Upper Limb
    Das, Swagata
    Kurita, Yuichi
    [J]. IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2020, 2 (02): : 269 - 281
  • [2] Lower Limb Assistive Device Design Optimization Using Musculoskeletal Modeling:A Review
    Grabke, Emerson Paul
    Masani, Kei
    Andrysek, Jan
    [J]. JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2019, 13 (04):
  • [3] Musculoskeletal upper limb modeling with muscle activation for flexible body simulation
    Kim, SeongYong
    Kim, Dong-Min
    Chae, Soo-Won
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2009, 10 (04) : 123 - 129
  • [4] Musculoskeletal upper limb modeling with muscle activation for flexible body simulation
    SeongYong Kim
    Dong-Min Kim
    Soo-Won Chae
    [J]. International Journal of Precision Engineering and Manufacturing, 2009, 10 : 123 - 129
  • [5] Upper-Limb Assistive Device for the Elderly at Home
    Gu, Gwang Min
    Lee, Hyosang
    Heo, Pilwon
    Kim, Sangjoon J.
    Kim, Jung
    [J]. 2014 11TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2014, : 535 - 539
  • [6] Development of an Assistive Rehabilitation Device for Upper Limb Extremity
    Hamawy, Lara
    Hellani, Zahraa
    Abu-Zeidan, Stephanie
    HajjHassan, Mohamad
    Abou Ali, Mohamad
    Kassem, Abdallah
    [J]. 2019 FIFTH INTERNATIONAL CONFERENCE ON ADVANCES IN BIOMEDICAL ENGINEERING (ICABME), 2019, : 204 - 207
  • [7] Implementation of wearable device for upper limb rehabilitation using embedded IoT
    Babu, M. Veeresh
    Ramya, V.
    Murugan, V. Senthil
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING SYSTEMS MODELLING AND SIMULATION, 2024, 15 (02) : 90 - 95
  • [8] Development of a Tele-Rehabilitation System Using an Upper Limb Assistive Device
    Tanaka, Eiichiro
    Lian, Wei-Liang
    Liao, Yun-Ting
    Yang, Hao
    Li, Li-Ning
    Lee, Hee-Hyol
    Shimodozono, Megumi
    [J]. JOURNAL OF ROBOTICS AND MECHATRONICS, 2021, 33 (04) : 877 - 886
  • [9] Musculoskeletal Model to Predict Muscle Activity During Upper Limb Movement
    Tamilselvam, Yokhesh K.
    Ganguly, Jacky
    Patel, Rajni, V
    Jog, Mandar
    [J]. IEEE ACCESS, 2021, 9 : 111472 - 111485
  • [10] Evaluation of the effectiveness of muscle assistive device using muscle fatigue analysis
    Lee, Youngjin
    Chee, Youngjoon
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2112 - 2115