Development of Heat Stress Forecasting System in Mechanically Ventilated Broiler House Using Dynamic Energy Simulation

被引:2
|
作者
Cho, Jeong-Hwa [1 ]
Lee, In-Bok [2 ,3 ]
Lee, Sang-Yeon [1 ]
Park, Se-Jun [1 ]
Jeong, Deuk-Young [1 ]
Decano-Valentin, Cristina [1 ,4 ]
Kim, Jun-Gyu [1 ]
Choi, Young-Bae [1 ]
Jeong, Hyo-Hyeog [1 ]
Yeo, Uk-Hyeon [5 ]
Lee, Seung-Jae [6 ]
机构
[1] Seoul Natl Univ, Coll Agr & Life Sci, Res Inst Agr & Life Sci, 1 Gwanak Ro, Seoul 08826, South Korea
[2] Seoul Natl Univ, Coll Agr & Life Sci, Res Inst Agr & Life Sci, Dept Rural Syst Engn,Global Smart Farm Convergenc, 1 Gwanak Ro, Seoul 08826, South Korea
[3] Seoul Natl Univ, Res Inst Green Eco Engn, Inst Green Bio Sci & Technol, 1 Gwanak Ro, Seoul 08826, South Korea
[4] Mariano Marcos State Univ, Coll Engn, Dept Agr & Biosyst Engn, Batac 2906, Philippines
[5] Elect & Telecommun Res Inst, Anim & Aquaculture Intelligence Res Ctr, 218 Gajeong Ro, Daejeon 34129, South Korea
[6] Seoul Natl Univ, Natl Ctr AgroMeteorol NCAM, 1 Gwanak Ro, Seoul 08826, South Korea
来源
AGRICULTURE-BASEL | 2022年 / 12卷 / 10期
关键词
broiler house; building energy simulation; forecasting system; heat stress index; temperature humidity index (THI); TEMPERATURE; HUMIDITY; PERFORMANCE; TUNNEL;
D O I
10.3390/agriculture12101666
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
The internal rearing environment of livestock houses has become an important issue in the last few years due to the rapid increase in meat consumption. As the number of days of heat waves increase continuously, problems caused by abnormal weather changes steadily occurred. Thus, the main goal of this study is to develop a technology that can automatically calculate heat stress for livestock by considering weather forecast data. Specifically, a web-based heat stress forecasting system for the evaluation of heat stress in broilers was developed. The field experiments were carried out at the selected broiler house to measure and analyze the external weather, the internal environment, and the ventilation flow rate of fans used in tunnel ventilation. The developed model was validated by comparing the field and simulated thermal environment values. Based on a reliable model, Land-Atmosphere Modeling Package (LAMP) weather forecast data was used to show the stress index on the internal rearing environment with a heat stress index suitable for South Korea. When the users input the farm location, structure and equipment, and rearing information, users responded after receiving heat stress from the broiler raised in a mechanically ventilated broiler house.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Dynamic energy modelling for analysis of the thermal and hygroscopic environment in a mechanically ventilated duck house
    Lee, Sang-Yeon
    Lee, In-Bok
    Kim, Rack-Woo
    Yeo, Uk-Hyeon
    Kim, Jun-Gyu
    Kwon, Kyeong-Seok
    [J]. BIOSYSTEMS ENGINEERING, 2020, 200 : 431 - 449
  • [2] Minimizing heat stress and energy demand for heating in mechanically ventilated poultry animal houses
    Struck, Christian
    Kuelpmann, Ruediger
    Sax, Markus
    Hartmann, Anne
    [J]. BAUPHYSIK, 2014, 36 (06) : 298 - 308
  • [3] Improvement of the ventilation system of a naturally ventilated broiler house in the cold season using computational simulations
    Seo, I. -H.
    Lee, I. -B.
    Moon, O. -K.
    Kim, H. -T.
    Hwang, H. -S.
    Hong, S. -W.
    Bitog, J. P.
    Yoo, J. -I.
    Kwon, K. -S.
    Kim, Y. -H.
    Han, J. -W.
    [J]. BIOSYSTEMS ENGINEERING, 2009, 104 (01) : 106 - 117
  • [4] Study on the utilization of heat in the mechanically ventilated Trombe wall in a house with a central air conditioning and air circulation system
    Ma, Qingsong
    Fukuda, Hiroatsu
    Lee, Myonghyang
    Kobatake, Takumi
    Kuma, Yuko
    Ozaki, Akihito
    [J]. APPLIED ENERGY, 2018, 222 : 861 - 871
  • [5] Long axis heat distribution in a tunnel-ventilated broiler house equipped with an evaporative pad cooling system
    Dagtekin, M.
    Karaca, C.
    Yildiz, Y.
    [J]. ANIMAL PRODUCTION SCIENCE, 2009, 49 (12) : 1125 - 1131
  • [6] Development of an early warning system for a broiler house using computer vision
    Kashiha, Mohammadamin
    Pluk, Arno
    Bahr, Claudia
    Vranken, Erik
    Berckmans, Daniel
    [J]. BIOSYSTEMS ENGINEERING, 2013, 116 (01) : 36 - 45
  • [7] Modeling and identification of the hygro-thermal parameters of mechanically-ventilated broiler house using prediction error: Assessment in cold conditions
    Lahlouh, Ilyas
    Khouili, Driss
    Bouganssa, Issam
    Elakkary, Ahmed
    Sefiani, Nacer
    [J]. JOURNAL OF THERMAL BIOLOGY, 2024, 119
  • [8] Simulation and validation model for using the energy produced from broiler litter waste in their house and its requirement of energy
    Omar, M. N.
    Samak, A. A.
    Keshek, M. H.
    Elsisi, S. F.
    [J]. RENEWABLE ENERGY, 2020, 159 : 920 - 928
  • [9] Microclimate measuring and fluid-dynamic simulation in an industrial broiler house: testing of an experimental ventilation system
    Bianchi, Biagio
    Giametta, Ferruccio
    La Fianza, Giovanna
    Gentile, Andrea
    Catalano, Pasquale
    [J]. VETERINARIA ITALIANA, 2015, 51 (02) : 85 - 92
  • [10] Computational fluid dynamics analysis of the thermal distribution of animal occupied zones using the jet-drop-distance concept in a mechanically ventilated broiler house
    Kwon, Kyeong-seok
    Lee, In-bok
    Zhang, G. Qiang
    Ha, Taehwan
    [J]. BIOSYSTEMS ENGINEERING, 2015, 136 : 51 - 68