Comparative performance of two point-of-care analysers for lipid testing

被引:0
|
作者
Shephard, Mark Ds [1 ]
Mazzachi, Beryl C. [1 ]
Shephard, Anne K. [1 ]
机构
[1] Flinders Univ S Australia, Flinders Univ Rural Clin Sch, Community Point Care Serv, Adelaide, SA 5001, Australia
关键词
point-of-care testing; lipids; cardiovascular disease; accuracy and precision; total analytical error;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The aim of this study was to compare the analytical performance of the Cholestech LDX and CardioChek PA lipid point-of-care devices to a CDC-certified laboratory. Inter-assay imprecision (n=10) for blood samples from 2 patients with different lipid profiles was 3.0% for total cholesterol, 2.6% for triglyceride, 5.2% for HDL cholesterol and 6.2% for calculated LDL cholesterol on the Cholestech, and 4.4% for total cholesterol, 4.8% for triglyceride, 7.0% for HDL cholesterol and 7.4% for calculated LDL cholesterol on the Cardiochek. In a patient comparison study (n=100), correlation coefficients (r) between the POCT and laboratory methods were greater than 0,90 for all tests for the Cholestech and greater than 0.84 for all tests for the Cardiochek. The mean difference (bias) between the results obtained on the Cholestech LDX and the laboratory method was not statistically significant; however the mean difference between the CardioChek and the laboratory method was statistically significant for total, HDL and LDL cholesterol (one way analysis of variance with Scheffe post-hoc test). The Cholestech LDX met the NCEP goal for total error for all analytes except LDL cholesterol. The CardioChek PA system met the NCEP total error goal for triglyceride but not the other lipid analytes. We conclude that the Cholestech LDX device is a suitable POCT device for cardiovascular risk assessment in the primary care setting, while the Cardiochek device requires more study and refinement.
引用
收藏
页码:561 / 566
页数:6
相关论文
共 50 条
  • [1] HbA1c-testing: Evaluation of two point-of-care analysers
    Dubach, Irina L.
    Christ, Emanuel R.
    Diem, Peter
    PRIMARY CARE DIABETES, 2019, 13 (06) : 583 - 587
  • [2] The impact of different point-of-care testing lipid analysers on cardiovascular disease risk assessment
    Whitehead, Simon John
    Ford, Clare
    Gama, Rousseau
    JOURNAL OF CLINICAL PATHOLOGY, 2014, 67 (06) : 535 - 539
  • [3] Point-of-care blood gas analysers: a performance evaluation
    St-Louis, P
    CLINICA CHIMICA ACTA, 2001, 307 (1-2) : 139 - 144
  • [4] Comparison of two point-of-care testing devices for lipid profiling
    Og, O'Donovan D.
    Sahm, L.
    Shannon, N.
    Byrne, S.
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2010, 19 (06) : 655 - 655
  • [5] A combined laboratory and field evaluation of the Cholestech LDX and CardioChek PA point-of-care testing lipid and glucose analysers
    Whitehead, Simon J.
    Ford, Clare
    Gama, Rousseau
    ANNALS OF CLINICAL BIOCHEMISTRY, 2014, 51 (01) : 54 - 67
  • [6] Analytical performance, agreement and user-friendliness of six urine test strip analysers in point-of-care testing
    Schot, M. J. C.
    van Delft, S.
    Kooijman-Buiting, A. M. J.
    de Wit, N. J.
    Hopstaken, R. M.
    ACTA CLINICA BELGICA, 2015, 70 : S12 - S12
  • [7] Verification of point-of-care analysers for C-reactive protein, lipid studies and glycated haemoglobin
    Li, Bobby
    Kumar, Ashwin
    Finlay, Chris
    van Drimmelen, Marie
    Barnes, Elly
    Southby, Sandi
    Florkowski, Chris
    PATHOLOGY, 2023, 55 (07) : 989 - 999
  • [8] Performance evaluation of Barozen Lipid Plus for point-of-care testing of lipid profiles: a method comparison study
    Yu, Soojoung
    Sun, Hwa Yeon
    Yoo, Byungwook
    JOURNAL OF YEUNGNAM MEDICAL SCIENCE, 2023, 40 : S73 - S80
  • [9] Simultaneous point-of-care testing of blood lipid profile and glucose: Performance evaluation of the GCare Lipid Analyzer
    Kim, Ha Nui
    Yoon, Soo-Young
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (12)
  • [10] The point of point-of-care testing
    Kassaye, Seble G.
    Katzenstein, David
    LANCET, 2011, 378 (9802): : 1532 - 1533