Pressure-Aware Control Layer Optimization for Flow-Based Microfluidic Biochips

被引:16
|
作者
Wang, Qin [1 ]
Xu, Yue [1 ]
Zuo, Shiliang [1 ]
Yao, Hailong [1 ]
Ho, Tsung-Yi [2 ]
Li, Bing [3 ]
Schlichtmann, Ulf [3 ]
Cai, Yici [1 ]
机构
[1] Tsinghua Univ, Dept Comp Sci & Technol, Taipei 10617, Taiwan
[2] Natl Tsing Hua Univ, Dept Comp Sci, Hsinchu 30013, Taiwan
[3] Tech Univ Munich, Chair Elect Design Automat, D-80333 Munich, Germany
基金
中国国家自然科学基金;
关键词
Flow-based microfluidic biochips; control layer; multiplexer optimization; pressure deviation; Hamming-distance; SOFT LITHOGRAPHY; VALVES; SCALE;
D O I
10.1109/TBCAS.2017.2766210
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flow-based microfluidic biochips are attracting increasing attention with successful biomedical applications. One critical issue with flow-based microfluidic biochips is the large number of microvalves that require peripheral control pins. Even using the broadcasting addressing scheme, i.e., one control pin controls multiple microvalves simultaneously, thousands of microvalves would still require hundreds of control prins, which is unrealistic. To address this critical challenge in control scalability, the control-layer multiplexer is introduced to effectively reduce the number of control pins into log scale of the number of microvalves. There are two practical design issues with the control-layer multiplexer: (1) the reliability issue caused by the frequent control-valve switching, and (2) the pressure degradation problem caused by the control-valve switching without pressure refreshing from the pressure source. This paper addresses these two design issues by the proposed Hamming-distance-based switching sequence optimization method and the XOR-based pressure refreshing method. Simulation results demonstrate the effectiveness and efficiency of the proposed methods with an average 77.2% (maximum 89.6%) improvement in total pressure refreshing cost, and an average 88.5% (maximum 90.0%) improvement in pressure deviation.
引用
收藏
页码:1488 / 1499
页数:12
相关论文
共 50 条
  • [1] Control-Layer Optimization for Flow-Based mVLSI Microfluidic Biochips
    Hu, Kai
    Dinh, Trung Anh
    Ho, Tsung-Yi
    Chakrabarty, Krishnendu
    [J]. 2014 INTERNATIONAL CONFERENCE ON COMPILERS, ARCHITECTURE AND SYNTHESIS FOR EMBEDDED SYSTEMS (CASES), 2014,
  • [2] Testing of Flow-Based Microfluidic Biochips
    Hu, Kai
    Ho, Tsung-Yi
    Chakrabarty, Krishnendu
    [J]. 2013 IEEE 31ST VLSI TEST SYMPOSIUM (VTS), 2013,
  • [3] Control-Layer Routing and Control-Pin Minimization for Flow-Based Microfluidic Biochips
    Hu, Kai
    Trung Anh Dinh
    Ho, Tsung-Yi
    Chakrabarty, Krishnendu
    [J]. IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2017, 36 (01) : 55 - 68
  • [4] SOLAR: Simultaneous Optimization of Control-Layer Pins Placement and Channel Routing in Flow-Based Microfluidic Biochips
    Wu, Jia-Lin
    Li, Katherine Shu-Min
    Li, Jain-De
    Wang, Sying-Jyan
    Ho, Tsung-Yi
    [J]. 2018 INTERNATIONAL SYMPOSIUM ON VLSI DESIGN, AUTOMATION AND TEST (VLSI-DAT), 2018,
  • [5] Waste-aware Fluid Volume Assignment for Flow-Based Microfluidic Biochips
    Schneider, Alexander
    Pop, Paul
    Madsen, Jan
    [J]. 2017 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP 2017), 2017,
  • [6] Hamming-Distance-Based Valve-Switching Optimization for Control-Layer Multiplexing in Flow-Based Microfluidic Biochips
    Wang, Qin
    Zuo, Shiliang
    Yao, Hailong
    Ho, Tsung-Yi
    Li, Bing
    Schlichtmann, Ulf
    Cai, Yici
    [J]. 2017 22ND ASIA AND SOUTH PACIFIC DESIGN AUTOMATION CONFERENCE (ASP-DAC), 2017, : 524 - 529
  • [7] Scheduling and Optimization of Genetic Logic Circuits on Flow-Based Microfluidic Biochips
    Chen, Yu-Jhih
    Sharma, Sumit
    Roy, Sudip
    Ho, Tsung-Yi
    [J]. PROCEEDINGS OF THE 2017 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE), 2017, : 1805 - 1810
  • [8] Microfluidic Trojan Design in Flow-based Biochips
    Shayan, Mohammed
    Bhattacharjee, Sukanta
    Song, Yong-Ak
    Chakrabarty, Krishnendu
    Karri, Ramesk
    [J]. PROCEEDINGS OF THE 2020 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE 2020), 2020, : 1037 - 1042
  • [9] Fault Diagnosis for Flow-Based Microfluidic Biochips
    Hu, Kai
    Bhattacharya, Bhargab B.
    Chakrabarty, Krishnendu
    [J]. 2015 IEEE 33RD VLSI TEST SYMPOSIUM (VTS), 2015,
  • [10] Integrated Flow-Control Codesign Methodology for Flow-Based Microfluidic Biochips
    Yao, Hailong
    Wang, Qin
    Ru, Yizhong
    Cai, Yici
    Ho, Tsung-Yi
    [J]. IEEE DESIGN & TEST, 2015, 32 (06) : 60 - 68