Detection of Potato ring rot Pathogen Clavibacter michiganensis subsp. sepedonicus by Loop-mediated isothermal amplification (LAMP) assay

被引:18
|
作者
Sagcan, Hasan [1 ]
Kara, Neslihan Turgut [2 ]
机构
[1] Istanbul Univ, Inst Sci, Program Mol Biol & Genet, Istanbul, Turkey
[2] Istanbul Univ, Fac Sci, Dept Mol Biol & Genet, TR-34134 Istanbul, Turkey
关键词
REAL-TIME PCR; POLYMERASE-CHAIN-REACTION; POINT-OF-CARE; MOLECULAR DIAGNOSTICS; SENSITIVE DETECTION; PLANT-PATHOGENS; TUBERS; VIRUS; SPOT;
D O I
10.1038/s41598-019-56680-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Clavibacter michiganensis subsp. sepedonicus (CMS) is an important bacterial plant pathogen causing potato ring rot disease. Rapid diagnosis of CMS is crucial because of the economic losses caused by serious harvest losses. Although there are serological tests used in the rapid diagnosis of CMS, they are not widely used because of their low sensitivity. The DNA-based PCR methods, which are highly sensitive, do not have the possibility of on-site diagnosis, especially since they require serious laboratory infrastructure. In recent years, scientists have been working on alternative amplification methods to develop DNA-based point of care (POC) diagnostic methods. Accordingly, the loop-mediated isothermal amplification (LAMP) method, which was developed in the early 2000s, provides an important convenience for DNA-based tests to use in the field. Due to the unique design of primers, more amplification products could be create in a shorter time than conventional amplification methods without needing a temperature cycle, and it can be applied with the aid of a simple heater without requiring a laboratory environment. In this study, efficient LAMP method for the detection of CMS has optimized. For device-independent detection of LAMP products, colorimetric method and LFD has used.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Detection of Potato ring rot Pathogen Clavibacter michiganensis subsp. sepedonicus by Loop-mediated isothermal amplification (LAMP) assay
    Hasan Sagcan
    Neslihan Turgut Kara
    [J]. Scientific Reports, 9
  • [2] Loop-mediated amplification (LAMP) for specific detection of the tomato pathogen, Clavibacter michiganensis subsp michiganensis
    Yasuhara-Bell, J. H.
    Alvarez, A. M.
    [J]. PHYTOPATHOLOGY, 2012, 102 (07) : 141 - 141
  • [3] On site testing for Clavibacter michiganensis subsp. sepedonicus in potato and environmental samples using loop mediated isothermal amplification
    Woodhall, J.
    Hetherington, F.
    Perkins, K.
    Lekuona, H.
    Fairchild, K.
    Wharton, P. S.
    [J]. PHYTOPATHOLOGY, 2015, 105 (11) : 149 - 150
  • [4] Nested PCR for Ultrasensitive Detection of the Potato Ring Rot Bacterium, Clavibacter michiganensis subsp. sepedonicus
    Lee, I.-M.
    Bartoszyk, I. M.
    Gundersen, D. E.
    Mogen, B.
    [J]. Applied and Environmental Microbiology, 63 (07):
  • [5] Nested PCR for ultrasensitive detection of the potato ring rot bacterium, Clavibacter michiganensis subsp. sepedonicus
    Lee, IM
    Bartoszyk, IM
    Gundersen, DE
    Mogen, B
    Davis, RE
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1997, 63 (07) : 2625 - 2630
  • [6] Lateral flow immunoassay for rapid detection of potato ring rot caused by Clavibacter michiganensis subsp. sepedonicus
    I. V. Safenkova
    I. A. Zaitsev
    G. K. Pankratova
    Yu. A. Varitsev
    A. V. Zherdev
    B. B. Dzantiev
    [J]. Applied Biochemistry and Microbiology, 2014, 50 : 675 - 682
  • [7] Plant-to-plant transmission of the bacterial ring rot pathogen Clavibacter michiganensis subsp. sepedonicus
    MansfeldGiese, K
    [J]. POTATO RESEARCH, 1997, 40 (02) : 229 - 235
  • [8] Chemical Eradication of the Ring Rot Bacterium Clavibacter michiganensis subsp. sepedonicus on Potato Storage Crates
    L. H. Stevens
    J. G. Lamers
    P. S. van der Zouwen
    O. Mendes
    W. van den Berg
    N. N. A. Tjou-Tam-Sin
    C. J. T. J. Jilesen
    P. M. Spoorenberg
    J. M. van der Wolf
    [J]. Potato Research, 2017, 60 : 145 - 158
  • [9] A Loop-Mediated Isothermal Amplification (LAMP) Assay for the Detection of Treponema pallidum subsp. pertenue
    Basing, Laud Anthony
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2019, 152 : S128 - S128
  • [10] Utility of a loop-mediated amplification assay for detection of Clavibacter michiganensis subsp michiganensis in seeds and plant tissues
    Yasuhara-Bell, Jarred
    Baysal-Gurel, Fulya
    Miller, Sally A.
    Alvarez, Anne M.
    [J]. CANADIAN JOURNAL OF PLANT PATHOLOGY, 2015, 37 (03) : 260 - 266