COMPARISON OF TWO FAT-SUPPRESSED MAGNETIC RESONANCE IMAGING PULSE SEQUENCES TO STANDARD T2-WEIGHTED IMAGES FOR BRAIN PARENCHYMAL CONTRAST AND LESION DETECTION IN DOGS WITH INFLAMMATORY INTRACRANIAL DISEASE

被引:4
|
作者
Young, Benjamin D. [1 ]
Mankin, Joseph M. [2 ]
Griffin, John F. [1 ]
Fosgate, Geoffrey T. [3 ]
Fowler, Jennifer L. [4 ]
Levine, Jonathan M. [2 ]
机构
[1] Texas A&M Univ, Coll Vet Med & Biomed Sci, Dept Large Anim Clin Sci, College Stn, TX 77843 USA
[2] Texas A&M Univ, Coll Vet Med & Biomed Sci, Dept Small Anim Clin Sci, College Stn, TX 77843 USA
[3] Univ Pretoria, Dept Prod Anim Studies, ZA-0002 Onderstepoort, South Africa
[4] Oregon State Univ, Dept Clin Sci, Coll Vet Med, Corvallis, OR 97331 USA
关键词
brain; dog; fat suppression; imaging; MRI; INVERSION-RECOVERY; HIGH-FIELD; SPIN-ECHO; STIR SEQUENCE; CORD LESIONS; MR; TIME; ENHANCEMENT; FEATURES; SYSTEM;
D O I
10.1111/vru.12220
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
T2-weighted (T2w) sequences are commonly relied upon in magnetic resonance imaging protocols for the detection of brain lesions in dogs. Previously, the effect of fluid suppression via fluid-attenuated inversion recovery (FLAIR) has been compared to T2-weighting with mixed results. Short tau inversion recovery (STIR) has been reported to increase the detection of some CNS lesions in people. The purpose of the current study was to evaluate the effect of fat suppression on brain parenchymal contrast resolution and lesion detection in dogs. We compared three sequences: T2w images, STIR, and T2w FLAIR with chemical fat suppression (T2-FLAIR-FS) in dogs with meningoencephalitis. Dogs with meningoencephalitis and dogs with idiopathic epilepsy were retrospectively identified and anonymized. Evaluators recorded the presence or absence of lesions within 12 predetermined brain regions on randomized sequences, viewing and scoring each sequence individually. Additionally, signal-to-noise ratios, contrast-to-noise ratios, and relative contrast (RC) were measured in a reference population. Short tau inversion recovery sequences had the highest RC between gray and white matter. While descriptively more lesions were identified by evaluators on T2-FLAIR-FS images, there was no statistical difference in the relative sensitivity of lesion detection between the sequences. Nor was there a statistical difference in false lesion detection within our reference population. Short tau inversion recovery may be favored for enhanced anatomic contrast depiction in brain imaging. No benefit of the inclusion of a fat-suppressed T2-FLAIR sequence was found. (C) 2014 American College of Veterinary Radiology.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 43 条
  • [1] Focal hepatic lesion detection: Comparison of four fat-suppressed T2-weighted MR imaging pulse sequences
    Kanematsu, M
    Hoshi, H
    Itoh, K
    Murakami, T
    Hori, M
    Kondo, H
    Yokoyama, R
    Nakamura, H
    RADIOLOGY, 1999, 211 (02) : 363 - 371
  • [2] Assessment of inflammation in idiopathic orbital myositis with fat-suppressed T2-weighted magnetic resonance imaging
    Kubota, Toshinobu
    Kano, Hiroshi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (04) : 718 - 720
  • [3] T2-weighted magnetic resonance imaging of the liver: comparison of fat-suppressed GRASE with conventional spin echo, fat-suppressed turbo spin echo, and gradient echo at 1.0 T
    A. H. Karantanas
    N. Papanikolaou
    Abdominal Imaging, 2001, 26 : 139 - 145
  • [4] T2-weighted magnetic resonance imaging of the liver: comparison of fat-suppressed GRASE with conventional spin echo, fat-suppressed turbo spin echo, and gradient echo at 1.0 T
    Karantanas, AH
    Papanikolaou, N
    ABDOMINAL IMAGING, 2001, 26 (02): : 139 - 145
  • [5] Findings of fat-suppressed T2-weighted and diffusion-weighted magnetic resonance imaging in the diagnosis of non-palpable testes
    Kato, Toshiki
    Kojima, Yoshiyuki
    Kamisawa, Hideyuki
    Takeuchi, Mitsuru
    Mizuno, Kentaro
    Sasaki, Shigeru
    Kohri, Kenjiro
    Hayashi, Yutaro
    BJU INTERNATIONAL, 2011, 107 (02) : 290 - 294
  • [6] MR-IMAGING OF HEAD AND NECK TUMORS - COMPARISON OF T1-WEIGHTED CONTRAST-ENHANCED FAT-SUPPRESSED IMAGES WITH CONVENTIONAL T2-WEIGHTED AND FAST SPIN-ECHO T2-WEIGHTED IMAGES
    ROSS, MR
    SCHOMER, DF
    CHAPPELL, P
    ENZMANN, DR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 173 - 178
  • [7] Focal hepatic lesion detection: Comparison of four T2-weighted MR imaging pulse sequences
    Kanematsu, M
    Hoshi, H
    Murakami, T
    Inaba, Y
    Hori, M
    Nandate, Y
    Yokoyama, R
    Nakamura, H
    RADIOLOGY, 1998, 206 (01) : 167 - 175
  • [8] Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T2-weighted Images
    Lee, Young Han
    Hahn, Seok
    Kim, Eunju
    Suh, Jin-Suck
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (04) : 371 - 378
  • [9] Intracranial meningeal disease: Comparison of contrast-enhanced MR imaging with fluid-attenuated inversion recovery and fat-suppressed T1-weighted sequences
    Galassi, W
    Phuttharak, W
    Hesselink, JR
    Healy, JF
    Dietrich, RB
    Imbesi, SG
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (03) : 553 - 559
  • [10] T2-WEIGHTED MR IMAGING OF FOCAL HEPATIC-LESIONS - COMPARISON OF VARIOUS RARE AND FAT-SUPPRESSED SPIN-ECHO SEQUENCES
    SEMELKA, RC
    SHOENUT, JP
    KROEKER, RM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02): : 323 - 327