A three-dimensional evaluation of microleakage of class V cavities prepared by the very short pulse mode of the erbium:yttrium-aluminium-garnet laser

被引:4
|
作者
Jukic Krmek, Silvana [1 ]
Bogdan, Ivana [2 ]
Simeon, Paris [1 ]
Mehicic, Goranka Prpic [1 ]
Katanec, Davor [3 ]
Anic, Ivica [1 ]
机构
[1] Univ Zagreb, Dept Endodont & Restorat Dent, Sch Dent Med, Gunduliceva 5, Zagreb 10000, Croatia
[2] Private Practice, Zagreb 10000, Croatia
[3] Univ Zagreb, Dept Oral Surg, Sch Dent Med, Zagreb 10000, Croatia
关键词
Erbium:yttrium-aluminium-garnet (Er:YAG) laser; Class V cavities; Microleakage; Very short pulse; Flowable resins; Cavity preparation; ER-YAG-LASER; SHEAR BOND STRENGTH; COMPOSITE RESIN; DENTIN; IRRADIATION; RESTORATIONS; TEMPERATURE; DURATION; ADHESION; SURFACE;
D O I
10.1007/s10103-009-0707-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to evaluate microleakage along resin restoration in cavities prepared with an erbium:yttrium-aluminium-garnet (Er:YAG) laser, with and without acid etching, and to compare it with that in diamond-drilled cavities. Thirty intact molars were divided into three equal groups. In the teeth in group I, class V cavities were prepared with a diamond drill. Cavities in groups II and III were prepared with an Er:YAG laser (400 mJ/15 Hz for enamel and 250 mJ/10 Hz for dentine). The cavities in groups I and II were acid-etched and adhesive and flowable composite were applied to all cavities. The specimens were first immersed in dye for 24 h and then in 5% nitric acid for 72 h for softening. The fillings were extracted and photographed through a dissecting microscope. The leakage area was measured with specially designed software. The Kruskal-Wallis test showed that the best ranking was group II [mean range (m.r.) = 27.46], followed by group I (m.r. = 33.48) and, lastly, group III (m.r. = 45.15). The differences between groups I and III (P = 0.023) and between groups II and III were statistically significant (P = 0.080). The least microleakage was found in those cavities prepared by Er:YAG laser and subsequently acid-etched, whereas the most leakage was in the lased cavities that had not been etched; the traditional diamond-drilled acid-etched cavities produced medium leakage.
引用
收藏
页码:823 / 828
页数:6
相关论文
共 17 条
  • [1] A three-dimensional evaluation of microleakage of class V cavities prepared by the very short pulse mode of the erbium:yttrium–aluminium–garnet laser
    Silvana Jukić Krmek
    Ivana Bogdan
    Paris Simeon
    Goranka Prpić Mehičić
    Davor Katanec
    Ivica Anić
    Lasers in Medical Science, 2010, 25 : 823 - 828
  • [2] Microleakage of glass ionomer formulations after erbium:yttrium-aluminium-garnet laser preparation
    Delme, Katleen I. M.
    Deman, Peter J.
    De Bruyne, Mieke A. A.
    Nammour, Samir
    De Moor, Roeland J. G.
    LASERS IN MEDICAL SCIENCE, 2010, 25 (02) : 171 - 180
  • [3] A three-dimensional evaluation of microleakage of the class V cavities restored with flowables
    Simeon, Paris
    Jukic Krmek, Silvana
    Prpic-Mehicic, Goranka
    Smojver, Ivica
    Anic, Ivica
    Pelivan, Ivica
    MEDICINSKI GLASNIK, 2009, 6 (02) : 249 - 255
  • [4] Influence of etching with erbium, chromium:yttrium–scandium–gallium–garnet laser on microleakage of class V restoration
    Juliana Marotti
    Vinícius Rangel Geraldo-Martins
    Marina Stella Bello-Silva
    Carlos de Paula Eduardo
    Christian Apel
    Norbert Gutknecht
    Lasers in Medical Science, 2010, 25 : 325 - 329
  • [5] Influence of etching with erbium, chromium:yttrium-scandium-gallium-garnet laser on microleakage of class V restoration
    Marotti, Juliana
    Geraldo-Martins, Vinicius Rangel
    Bello-Silva, Marina Stella
    Eduardo, Carlos de Paula
    Apel, Christian
    Gutknecht, Norbert
    LASERS IN MEDICAL SCIENCE, 2010, 25 (03) : 325 - 329
  • [6] Effect of the erbium:yttrium-aluminum-garnet laser or diamond bur cavity preparation on the marginal microleakage of class V cavities restored with different adhesives and composite systems
    Yaman, Batu Can
    Guray, Begum Efes
    Dorter, Can
    Gomec, Yavuz
    Yazicioglu, Oktay
    Erdilek, Dina
    LASERS IN MEDICAL SCIENCE, 2012, 27 (04) : 785 - 794
  • [7] Effect of the erbium:yttrium-aluminum-garnet laser or diamond bur cavity preparation on the marginal microleakage of class V cavities restored with different adhesives and composite systems
    Batu Can Yaman
    Begum Efes Guray
    Can Dorter
    Yavuz Gomeç
    Oktay Yazıcıoglu
    Dina Erdilek
    Lasers in Medical Science, 2012, 27 : 785 - 794
  • [8] Effect of acid etching duration on tensile bond strength of composite resin bonded to erbium:yttrium-aluminium-garnet laser-prepared dentine. Preliminary study
    Chousterman, M.
    Heysselaer, D.
    Dridi, S. M.
    Bayet, F.
    Misset, B.
    Lamard, L.
    Peremans, A.
    Nyssen-Behets, C.
    Nammour, S.
    LASERS IN MEDICAL SCIENCE, 2010, 25 (06) : 855 - 859
  • [9] Comparative Evaluation of Photoablative Efficacy of Erbium: Yttrium-Aluminium-Garnet and Diode Laser for the Treatment of Gingival Hyperpigmentation. A Randomized Split-Mouth Clinical Trial
    Giannelli, Marco
    Formigli, Lucia
    Bani, Daniele
    JOURNAL OF PERIODONTOLOGY, 2014, 85 (04) : 554 - 561
  • [10] Microleakage of repaired class V silorane and nano-hybrid composite restorations after preparation with erbium:yttrium–aluminum–garnet laser and diamond bur
    Batu Can Yaman
    Begüm Güray Efes
    Can Dörter
    Yavuz Gömeç
    Dina Erdilek
    Oktay Yazıcıoğlu
    Lasers in Medical Science, 2011, 26 : 163 - 170