Calibration of high-resolution X-ray tomography with atomic force microscopy

被引:3
|
作者
Kalukin, AR
Winn, B
Wang, YX
Jacobsen, C
Levine, ZH
Fu, J
机构
[1] Rensselaer Polytech Inst, Troy, NY 12180 USA
[2] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[3] SUNY Stony Brook, Stony Brook, NY 11794 USA
基金
美国国家科学基金会;
关键词
atomic force microscopy; scanning electron microscope; x-ray microscopy;
D O I
10.6028/jres.105.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For two-dimensional x-ray imaging of thin films, the technique of scanning transmission x-ray microscopy (STXM) has achieved images with feature sizes as small as 40 nm in recent years. However, calibration of three-dimensional tomographic images that are produced with STXM data at this scale has not yet been described in the scientific literature, and the calibration procedure has novel problems that have not been encountered by x-ray tomography carried out at a larger scale. In x-ray microtomography, for example, one always has the option of using optical imaging on a section of the object to verify the x-ray projection measurements. with STXM, on the other hand, the sample Features are too small to be resolved by light at optical wavelengths. This fact implies that one must rely on procedures with higher resolution, such as atomic force microscopy (AFM), for the calibration. Such procedures, however, generally depend on a highly destructive sectioning of the sample, and are difficult to interpret because they give surface information rather than depth information. In this article, a procedure for calibration is described that overcomes these limitations and achieves a calibration of an STXM tomography image with an AFM image and a scanning electron microscopy image of the same object. A Ge star-shaped pattern was imaged at a synchrotron with a scanning transmission x-ray microscope. Nineteen high-resolution projection images of 200x200 pixels were tomographically reconstructed into a three-dimensional image. Features in two-dimensional images as small as 40 nm and features as small as 80 nm in the three-dimensional reconstruction were resolved. Transverse length scales based on atomic force microscopy, scanning electron microscopy, x-ray transmission and tomographic reconstruction agreed to within 10 nm. Toward the center of the sample, the pattern thickness calculated from projection images was (51 +/- 15) nm vs (80 +/- 52) nm for tomographic reconstruction, where the uncertainties are evaluated at the level of two standard deviations.
引用
收藏
页码:867 / 874
页数:8
相关论文
共 50 条
  • [1] High-resolution compact X-ray microscopy
    Takman, P. A. C.
    Stollberg, H.
    Johansson, G. A.
    Holmberg, A.
    Lindblom, M.
    Hertz, H. M.
    [J]. JOURNAL OF MICROSCOPY, 2007, 226 (02) : 175 - 181
  • [2] HIGH-RESOLUTION X-RAY PROJECTION MICROSCOPY
    NIXON, WC
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1955, 232 (1191): : 475 - &
  • [3] High-Resolution and Large-Volume Tomography Reconstruction for X-Ray Microscopy
    Cheng, Chang-Chieh
    Hwu, Yeukuang
    Ching, Yu-Tai
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [4] High-resolution scanning x-ray diffraction microscopy
    Thibault, Pierre
    Dierolf, Martin
    Menzel, Andreas
    Bunk, Oliver
    David, Christian
    Pfeiffer, Franz
    [J]. SCIENCE, 2008, 321 (5887) : 379 - 382
  • [5] High-resolution X-ray microscopy for biological objects
    Kochubey, VI
    Gyunsburg, KE
    Zvezdova, NP
    Gorin, GB
    Sedova, YG
    [J]. SARATOV FALL MEETING '98: LIGHT SCATTERING TECHNOLOGIES FOR MECHANICS, BIOMEDICINE, AND MATERIAL SCIENCE, 1999, 3726 : 58 - 61
  • [6] HIGH-RESOLUTION ZONE PLATES FOR X-RAY MICROSCOPY
    MORRIS, D
    GENTILI, M
    BACIOCCHI, M
    CONTARINI, S
    DEGASPERIS, P
    GARIAZZO, C
    MAGGIORA, R
    MELPIGNANO, P
    MINNAJA, N
    NATALETTI, P
    ROSEI, R
    [J]. INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 539 - 542
  • [7] PROSPECTS IN HIGH-RESOLUTION X-RAY PHOTOELECTRON MICROSCOPY
    CAZAUX, J
    [J]. ULTRAMICROSCOPY, 1985, 17 (01) : 43 - 49
  • [8] High-resolution X-ray computed tomography of impactites
    Koeberl, C
    Denison, C
    Ketcham, RA
    Reimold, WU
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-PLANETS, 2002, 107 (E10)
  • [9] Recent trends in high-resolution X-ray tomography
    Mueller, Bert
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [10] High-resolution x-ray luminescence computed tomography
    Lun, Michael C.
    Li, Changqing
    [J]. MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317