Analysis of algebraic reconstruction technique for accurate imaging of gas temperature and concentration based on tunable diode laser absorption spectroscopy

被引:13
|
作者
Xia, Hui-Hui [1 ,2 ]
Kan, Rui-Feng [1 ]
Liu, Jian-Guo [1 ]
Xu, Zhen-Yu [1 ]
He, Ya-Bai [1 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Hefei 230022, Peoples R China
基金
中国国家自然科学基金;
关键词
algebraic reconstruction technique; 2D distribution; projection rays; accurate reconstruction; WATER-VAPOR CONCENTRATION; TOMOGRAPHY; SENSOR;
D O I
10.1088/1674-1056/25/6/064205
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
An improved algebraic reconstruction technique (ART) combined with tunable diode laser absorption spectroscopy(TDLAS) is presented in this paper for determining two-dimensional (2D) distribution of H2O concentration and temperature in a simulated combustion flame. This work aims to simulate the reconstruction of spectroscopic measurements by a multi-view parallel-beam scanning geometry and analyze the effects of projection rays on reconstruction accuracy. It finally proves that reconstruction quality dramatically increases with the number of projection rays increasing until more than 180 for 20 x 20 grid, and after that point, the number of projection rays has little influence on reconstruction accuracy. It is clear that the temperature reconstruction results are more accurate than the water vapor concentration obtained by the traditional concentration calculation method. In the present study an innovative way to reduce the error of concentration reconstruction and improve the reconstruction quality greatly is also proposed, and the capability of this new method is evaluated by using appropriate assessment parameters. By using this new approach, not only the concentration reconstruction accuracy is greatly improved, but also a suitable parallel-beam arrangement is put forward for high reconstruction accuracy and simplicity of experimental validation. Finally, a bimodal structure of the combustion region is assumed to demonstrate the robustness and universality of the proposed method. Numerical investigation indicates that the proposed TDLAS tomographic algorithm is capable of detecting accurate temperature and concentration profiles. This feasible formula for reconstruction research is expected to resolve several key issues in practical combustion devices.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Analysis of algebraic reconstruction technique for accurate imaging of gas temperature and concentration based on tunable diode laser absorption spectroscopy
    夏晖晖
    阚瑞峰
    刘建国
    许振宇
    何亚柏
    Chinese Physics B, 2016, (06) : 250 - 257
  • [2] Algebraic tomographic reconstruction of two-dimensional gas temperature based on tunable diode laser absorption spectroscopy
    Song, Junling
    Hong, Yanji
    Wang, Guangyu
    Pan, Hu
    APPLIED PHYSICS B-LASERS AND OPTICS, 2013, 112 (04): : 529 - 537
  • [3] Algebraic tomographic reconstruction of two-dimensional gas temperature based on tunable diode laser absorption spectroscopy
    Junling Song
    Yanji Hong
    Guangyu Wang
    Hu Pan
    Applied Physics B, 2013, 112 : 529 - 537
  • [4] Effect of temperature on methane gas concentration by tunable diode laser absorption spectroscopy
    Zhao, Yanjie
    Wei, Yubin
    Li, Yanfang
    Zhang, Tingting
    Wang, Chang
    Liu, Tongyu
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [5] A Measurement Plan of Gas Concentration and Temperature Distribution Reconstruction based on the Tunable Diode Laser Absorption Tomography
    Liu, Zhao-ran
    Jin, Xing
    Wang, Guang-yu
    Song, Jun-ling
    INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGING SPECTROSCOPY; AND TELESCOPES AND LARGE OPTICS, 2014, 9298
  • [6] Studies on gas concentration reconstruction methods for simultaneous temperature and H2O concentration tomographic imaging in a flame based on tunable diode laser absorption spectroscopy
    Zhai, Yunchu
    Wang, Fei
    OPTICAL ENGINEERING, 2021, 60 (02)
  • [7] Reconstruction of combustion temperature and gas concentration distributions using line-of-sight tunable diode laser absorption spectroscopy
    Zhang, Zhirong
    Sun, Pengshuai
    Pang, Tao
    Xia, Hua
    Cui, Xiaojuan
    Li, Zhe
    Han, Luo
    Wu, Bian
    Wang, Yu
    Sigrist, Markus W.
    Dong, Fengzhong
    OPTICAL ENGINEERING, 2016, 55 (07)
  • [8] Research on the Distribution of Gas Concentration of Two-Dimensional Reconstruction Based on Tunable Diode Laser Absorption Spectroscopy with Multispectral Absorption
    Zhang Li-fang
    Wang Fei
    Zhang Hai-dan
    Wu Qi
    Yan Jian-hua
    Cen Ke-fa
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (11) : 3485 - 3491
  • [9] Correction of Gas Concentration Based on Tunable Diode Laser Absorption Spectroscopy in Different Temperatures
    Qu, Ziqi
    Zhang, Shiling
    Xu, Yuxin
    Jiang, Meng
    Wang, Junlong
    SECOND SYMPOSIUM ON NOVEL TECHNOLOGY OF X-RAY IMAGING, 2019, 11068
  • [10] Two-dimensional tomography for gas concentration and temperature distributions based on tunable diode laser absorption spectroscopy
    Wang, F.
    Cen, K. F.
    Li, N.
    Jeffries, Jay B.
    Huang, Q. X.
    Yan, J. H.
    Chi, Y.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (04)