Arc flash calculations in systems protected by low-voltage circuit breakers

被引:4
|
作者
Gregory, GD [1 ]
Lyttle, I
Wellman, CM
机构
[1] Square D Co, Cedar Rapids, IA 52404 USA
[2] DuPont Co Inc, Wilmington, DE 19880 USA
关键词
arc flash; circuit breaker (CB); flash protection boundary; incident energy;
D O I
10.1109/TIA.2003.813721
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A series of previous papers has provided information regarding the are flash hazard and methods of calculating its potential impact on persons working on or near the equipment. This paper extends that base of information by focusing on the arcing current level and duration in low-voltage circuits protected by circuit breakers (CBs). It describes a method of calculating incident energy and the flash protection boundary due to arcing occurrences in equipment protected by CBs. This method provides convenient procedures for determining these values for generic situations in which some details of the CB are not known. Further, it provided a process for determining these values in typical feeder and branch circuit applications involving common transformers and cable sizes and lengths. The values are needed to determine safe work practices and appropriate Personal Protective Equipment to comply with NFPA 70E, Standard for Electrical Safety Requirements for Employee Workplaces.
引用
收藏
页码:1193 / 1199
页数:7
相关论文
共 50 条
  • [1] Arc flash energy limitations using low-voltage circuit breakers
    Gregory, GD
    Lyttle, I
    Wellman, CM
    INDUSTRY APPLICATIONS SOCIETY 49TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2002, : 291 - 299
  • [2] Applying low-voltage circuit breakers to limit arc flash energy
    Gregory, George
    Lippert, Kevin J.
    IEEE CONFERENCE RECORD OF 2007 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 2007, : 138 - +
  • [3] Applying low-voltage circuit breakers to limit arc flash energy
    Gregory, George
    Lippert, Kevin J.
    INDUSTRY APPLICATIONS SOCIETY 53RD ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2006, : 9 - +
  • [4] Applying Low-Voltage Circuit Breakers to Limit Arc-Flash Energy
    Gregory, George D.
    Lippert, Kevin J.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (04) : 1225 - 1229
  • [5] ARC REIGNITION IN AC LOW-VOLTAGE CIRCUIT-BREAKERS
    RUFFINO, C
    TARTAGLIA, M
    ELETTROTECNICA, 1976, 63 (06): : 577 - 582
  • [6] Electric Arc in Low-Voltage Circuit Breakers: Experiments and Simulation
    Iturregi, Araitz
    Barbu, Bogdan
    Torres, Esther
    Berger, Frank
    Zamora, Inmaculada
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2017, 45 (01) : 113 - 120
  • [7] BEHAVIOR OF SWITCHING ARC IN LOW-VOLTAGE LIMITER-CIRCUIT BREAKERS
    BELBEL, EM
    LAURAIRE, M
    IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1985, 8 (01): : 3 - 12
  • [8] Experimental and numerical studies of arc restrikes in low-voltage circuit breakers
    Fievet, C
    Barrault, M
    Chevrier, P
    Petit, P
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1997, 25 (05) : 954 - 960
  • [9] A comparison of arc-flash incident energy reduction techniques using low-voltage power circuit breakers
    Brown, William A.
    Shapiro, Ron
    2006 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, CONFERENCE RECORD, 2006, : 196 - +
  • [10] Static trips for low-voltage circuit breakers
    Rainin, V.E.
    2002, Allerton Press Inc. (73)