The long-term results of endoprosthetic replacement of the proximal tibia for bone tumours

被引:122
|
作者
Myers, G. J. C. [1 ]
Abudu, A. T. [1 ]
Carter, S. R. [1 ]
Tillman, R. M. [1 ]
Grimer, R. J. [1 ]
机构
[1] Royal Orthopaed Hosp, Birmingham B31 2AP, W Midlands, England
来源
关键词
D O I
10.1302/0301-620X.89B12.19481
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and 'servicing' procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and infection in the current version. The risk of revision for aseptic loosening in the fixed-hinge knees was 46% at ten years. This was reduced to 3% in the rotating-hinge knee with a hydroxyapatite collar. The cemented, rotating hinge design currently offers the best chance of long-term survival of the prosthesis.
引用
收藏
页码:1632 / 1637
页数:6
相关论文
共 50 条
  • [1] Endoprosthetic replacement of the distal femur for bone tumours - Long-term results
    Myers, G. J. C.
    Abudu, A. T.
    Carter, S. R.
    Tillman, R. M.
    Grimer, R. J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04): : 521 - 526
  • [2] Endoprosthetic replacement of the proximal humerus - Long-term results
    Kumar, D
    Grimer, RJ
    Abudu, A
    Carter, SR
    Tillman, RM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (05): : 717 - 722
  • [3] Very long-term outcomes after endoprosthetic replacement for malignant tumours of bone
    Grimer, R. J.
    Aydin, B. K.
    Wafa, H.
    Carter, S. R.
    Jeys, L.
    Abudu, A.
    Parry, M.
    BONE & JOINT JOURNAL, 2016, 98B (06): : 857 - 864
  • [4] Endoprosthetic replacement of the proximal tibia
    Grimer, RJ
    Carter, SR
    Tillman, RM
    Sneath, RS
    Walker, PS
    Unwin, PS
    Shewell, PC
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (03): : 488 - 494
  • [5] Endoprosthetic replacement of diaphyseal bone defects. Long-term results
    E. Aldlyami
    A. Abudu
    R. J. Grimer
    S. R. Carter
    R. M. Tillman
    International Orthopaedics, 2005, 29 : 25 - 29
  • [6] Endoprosthetic replacement of diaphyseal bone defects. Long-term results
    Aldlyami, E
    Abudu, A
    Grimer, RJ
    Carter, SR
    Tillman, RM
    INTERNATIONAL ORTHOPAEDICS, 2005, 29 (01) : 25 - 29
  • [7] Endoprosthetic replacement for malignant bone tumours of the proximal femur
    Rosa, MA
    Maccauro, G
    Muratori, F
    Rodà, MG
    HIP INTERNATIONAL, 2005, 15 (04) : 218 - 222
  • [8] Proximal ulna endoprosthetic replacement for bone tumours in young patients
    Mathew D. Sewell
    Sammy A. Hanna
    Rob C. Pollock
    William J. Aston
    John A. Skinner
    Gordon W. Blunn
    Stephen R. Cannon
    Timothy W. R. Briggs
    International Orthopaedics, 2012, 36 : 1039 - 1044
  • [9] Endoprosthetic replacement of the distal tibia and ankle joint for aggressive bone tumours
    Abudu, A
    Grimer, RJ
    Tillman, RM
    Carter, SR
    INTERNATIONAL ORTHOPAEDICS, 1999, 23 (05) : 291 - 294
  • [10] Endoprosthetic replacement of the distal tibia and ankle joint for aggressive bone tumours
    A. Abudu
    R. J Grimer
    R. M. Tillman
    S. R. Carter
    International Orthopaedics, 1999, 23 : 291 - 294