Glucose degradation products and peritoneal membrane function

被引:0
|
作者
Witowski, J
Bender, TO
Gahl, GM
Frei, U
Jörres, A
机构
[1] Humboldt Univ, Fak Med, Univ Klinikum Charite, Dept Nephrol & Med Intens Care, D-13353 Berlin, Germany
[2] Univ Poznan, Sch Med, Dept Pathophysiol, Poznan, Poland
来源
PERITONEAL DIALYSIS INTERNATIONAL | 2001年 / 21卷 / 02期
关键词
glucose degradation products; bioincompatibility; peritoneal dialysis fluids; peritoneal mesothelium;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background:The bioincompatibility of peritoneal dialysis fluids (PDF) in current use has been partially attributed to the presence of glucose degradation products (GDPs), which are generated during heat sterilization of PDF. Several of the GDPs have been identified and we have recently demonstrated that these GDPs per se may impair the viability and function of human peritoneal mesothelial cells (HPMC) in vitro. It is also possible that GDP-related toxicity is further exacerbated by the milieu of PDF. We review the current literature on GDP and present the results of experiments comparing the impact of heat- and filter-sterilized PDF on the viability and function of HPMC. Methods: Peritoneal dialysis fluids with low (1.5%) and high (4.25%) glucose concentrations were laboratory prepared according to the standard formula and sterilized either by heat (H-PDF; 121 degreesC, 0.2 MPa, 20 minutes) or filtration (F-PDF; 0.2 mu). The buildup of GDP was confirmed by UV absorbance at 284 nm. Confluent HPMC monolayers were exposed to these solutions mixed 1:1 with standard M199 culture medium. After 24 hours, cell viability was assessed with the MTT assay, and interleukin-1 beta -stimulated monocyte chemotactic protein-1 (MCP-1) release with specific immunoassay. Results: Exposure of HPMC to H-PDF resulted in a significant decrease in cell viability, with solutions containing 4.25% glucose being more toxic than 1.5% glucose-based PDF (27.4% +/- 3.4% and 53.4% +/- 11.0% of control values, respectively). In contrast, viability of HPMC exposed to F-PDF was not different from that of control cells. Moreover, treatment with H-PDF impaired the release of MCP-1 from HPMC to a significantly greater degree compared to F-PDF (17.4% and 24.9% difference for low and high glucose PDF, respectively). Conclusions: Exposure of HPMC to H-PDF significantly impairs cell viability and the capacity for generating MCP-1 compared to F-PDF. This effect is likely to be mediated by GDPs present in H-PDF but not in F-PDF.
引用
收藏
页码:201 / 205
页数:5
相关论文
共 50 条
  • [1] EFFECT OF GLUCOSE DEGRADATION PRODUCTS ON PERITONEAL FUNCTION IN RATS ON CHRONIC PERITONEAL DIALYSIS
    Kuzlan-Pawlaczyk, Malgorzata
    Pawlaczyk, Krzysztof
    Polubinska, Alicja
    Wisniewska-Elnur, Justyna
    Gorska, Kinga
    Wu, George
    Paul, Tam
    Carlsson, Ola
    Wieslander, Anders
    Czekalski, Stanislaw
    Breborowicz, Andrzej
    NEPHROLOGY, 2005, 10 : A66 - A67
  • [2] Effect of glucose degradation products on human peritoneal mesothelial cell function
    Witowski, J
    Korybalska, K
    Wisniewska, J
    Breborowicz, A
    Gahl, GM
    Frei, U
    Passlick-Deetjen, J
    Jörres, A
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2000, 11 (04): : 729 - 739
  • [3] Glucose degradation products and the peritoneal mesothelium
    Jörres, A
    Bender, TO
    Witowski, J
    PERITONEAL DIALYSIS INTERNATIONAL, 2000, 20 : S19 - S22
  • [4] Effect of glucose degradation products on the peritoneal membrane in a chronic inflammatory infusion model of peritoneal dialysis in the rat
    Park, SH
    Lee, EG
    Kim, IS
    Kim, YJ
    Cho, DK
    Kim, YL
    PERITONEAL DIALYSIS INTERNATIONAL, 2004, 24 (02): : 115 - 122
  • [5] Damage to the peritoneal membrane by glucose degradation products is mediated by the receptor for advanced glycation end-products
    Schwenger, Vedat
    Morath, Christian
    Salava, Alexander
    Amann, Kerstin
    Seregin, Yuri
    Deppisch, Reinhold
    Ritz, Eberhard
    Bierhaus, Angelika
    Nawroth, Peter P.
    Zeier, Martin
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 17 (01): : 199 - 207
  • [6] Hemodynamic effects of peritoneal dialysis solutions on the rat peritoneal membrane: Role of acidity, buffer choice, glucose concentration, and glucose degradation products
    Mortier, S
    De Vriese, AS
    Van de Voorde, J
    Schaub, TP
    Passlick-Deetjen, J
    Lameire, NH
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (02): : 480 - 489
  • [7] Cytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis
    Adib, Noushin
    Shekarchi, Maryam
    Hajimehdipoor, Homa
    Shalviri, Gloria
    Imaninejad, Maryam
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2011, 10 (01): : 113 - 117
  • [8] Evidence for less irritation to the peritoneal membrane in rats dialyzed with solutions low in glucose degradation products
    Wieczorowska-Tobis, K
    Brelinska, R
    Witowski, J
    Passlick-Deetjen, J
    Schaub, TP
    Schilling, H
    Breborowicz, A
    PERITONEAL DIALYSIS INTERNATIONAL, 2004, 24 (01): : 48 - 57
  • [9] Effects of neutral pH and reduced glucose degradation products in a new peritoneal dialysis solution on morphology of peritoneal membrane in rats
    Ikehara, O
    Nishimura, H
    Naito, T
    Higuchi, C
    Sanaka, T
    NEPHRON EXPERIMENTAL NEPHROLOGY, 2005, 100 (01): : E30 - E39
  • [10] Relative contribution of glucose, glucose degradation products and lactate in the development of long-term alterations in the peritoneal membrane.
    Mortier, S
    Faict, D
    Lameire, NH
    De Vriese, AS
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 35A - 35A