Thermal analysis of polymer heat exchangers for solar water heating: A case study

被引:37
|
作者
Liu, W [1 ]
Davidson, J [1 ]
Mantell, S [1 ]
机构
[1] Univ Minnesota, Dept Mech Engn, Minneapolis, MN 55455 USA
关键词
D O I
10.1115/1.1288027
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The feasibility of reducing the cost of solar water heating systems by using polymer heat exchangers is illustrated by comparing thermal performance and cost of heat exchangers made of nylon, cross linked polyethylene (PEX), or copper. Both tube-in-shell hear exchangers and immersed tube banks are considered. For the thermal analysis, the tube geometry and the arrangement of tubes are fixed and the heat transfer surface areas required to provide 3000 and 6000 W are determined Thermal performance is estimated using published heal transfer correlations. The nylon heat exchanger outperforms the PEX design, primarily because nylon is a stronger material. Consequently, the ratio of diameter to wall thickness required to withstand the operating pressure is greater and the conduction resistance across the polymer wall is less, The cost of nonoptimized nylon heat exchangers is about 80 percent of the cost of heat exchangers made of copper. Significant additional work is required to optimize the tube arrangement and geometry and to validate our initial estimates of thermal and economic performance. [S0199-6231(00)00802-9].
引用
收藏
页码:84 / 91
页数:8
相关论文
共 50 条
  • [1] Thermal analysis of polymer heat exchangers for solar water heating: A case study
    Liu, Wei, 2000, American Society of Mechanical Engineers (122):
  • [2] Analysis of horizontal mantle heat exchangers in solar water heating systems
    Morrison, GL
    Nasr, A
    Behnia, M
    Rosengarten, G
    SOLAR ENERGY, 1998, 64 (1-3) : 19 - 31
  • [3] TRANSIENT ANALYSIS OF CLOSED-LOOP SOLAR WATER HEATING-SYSTEM (EFFECT OF HEAT-EXCHANGERS)
    FAHMY, MFM
    ABDELSADEK, M
    ENERGY CONVERSION AND MANAGEMENT, 1990, 30 (04) : 343 - 355
  • [4] Analysis of the thermal performance of flat plate PCM heat exchangers for heating systems
    Prieto, M. M.
    Suarez, I.
    Gonzalez, B.
    APPLIED THERMAL ENGINEERING, 2017, 116 : 11 - 23
  • [5] Solar water heating: comprehensive review, critical analysis and case study
    Herez A.
    Jaber H.
    Hage H.E.
    Lemenand T.
    Chahine K.
    Ramadan M.
    Khaled M.
    International Journal of Thermofluids, 2023, 20
  • [6] Thermal economic analysis of auxiliary heat source of solar-assisted heat pump water heating system
    Mu, Zhen-Ying
    You, Shi-Jun
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2010, 43 (11): : 995 - 1002
  • [7] Heating water with hybrid tubular plate heat exchangers as heat condensers
    Hermanns, Manfred
    Euroheat and Power/Fernwarme International, 2021, 50 (06): : 35 - 39
  • [8] ANALYSIS AND DESIGN OF THE SOLAR ONE THERMAL STORAGE SUBSYSTEM HEAT-EXCHANGERS
    WEINER, FR
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (03): : 279 - 285
  • [9] Experimental thermal performance analysis of ground heat exchangers for space heating and cooling applications
    Sivasakthivel, T.
    Philippe, Mikael
    Murugesan, K.
    Verma, Vikas
    Hu, Pingfang
    RENEWABLE ENERGY, 2017, 113 : 1168 - 1181
  • [10] Empirical investigation and performance evaluation of flat-plate solar water heating systems: a comparative analysis with and without heat exchangers
    Balakrishnan, Ramkumar
    Chellasamy, Gopinathan
    Bojan, Vijay Bhaskar
    Machakalai, Rajesh Kumar
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2024,