Instrumentation, data acquisition and controls for temperature measurement of cold surfaces at 4.5 K and 80 K of SST-1 machine

被引:0
|
作者
Panchal, P. [1 ]
Sonara, D. [1 ]
Sarkar, B. [1 ]
Hattacharya, R. [1 ]
Panchal, R. [1 ]
Patel, R. [1 ]
Tank, J. [1 ]
Singh, M. [1 ]
Sahu, A. K. [1 ]
Saxena, Y. C. [1 ]
机构
[1] Inst Plasma Res, Gandhinagar 382428, Gujarat, India
关键词
temperature; superconducting magnets; transmitter; PLC; DAS;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Two-temperature regimes have been envisaged for the SST-1 machine, 80 K on the thermal shield and 4.5 K on the superconducting magnet system. The aim of temperature measurement is two folds (1) to monitor the temperature distribution as well as process parameters (ii) to achieve controlled cool down from 300 K to 4.5 K and 80 K. Temperature sensors have been mounted on cold surfaces at required locations to ease the operation during cool down and steady state. Techniques employed for temperature measurement and controls are based on continuous resistance measurement. Cernox (TM) sensors (Lakeshore made) and PT-102 have been used for the temperature measurement at 4.5 K and 80 K surfaces respectively. The data acquisition system (DAS) has been indigenously developed using 4-20 mA current loop temperature transmitter, which provided better functioning in terms of flexibility. The control functioning has been designed and developed using programmable logic controller with direct interfacing of the transmitter. The temperature data is obtained at the supervisory control and data acquisition of dedicated node. The developed DAS has been found to be very reliable and satisfactory.
引用
收藏
页码:981 / 988
页数:8
相关论文
共 3 条
  • [1] Performance validation tests on 80 K bubble type of shields for SST-1
    Sonara, Dashrath
    Tanna, Vipul
    Panchal, Rohit
    Bairagi, Nitin
    Gupta, Manoj K.
    Gupta, Naresh C.
    Patel, Ketan
    Nimavat, Hiren
    Srikanth, G. L. N.
    Sharma, Rajiv
    Shah, Pankil
    Khan, Ziauddin
    Pathan, Firoz Khan
    Yuvakiran, Paravastu
    George, Siju
    Raval, Dilip C.
    Parekh, Tejas
    Sharma, Aashoo
    Pradhan, Subrata
    CRYOGENICS, 2012, 52 (12) : 685 - 688
  • [2] Integrated Liquid Nitrogen Distribution Network for the Cooling of SST-1 80K Thermal Shields System
    Srikanth, G. L. N.
    Patel, K.
    Panchal, R.
    Shah, P.
    Tanna, V. L.
    Pradhan, S.
    Gupta, M. K.
    13TH CRYOGENICS 2014 IIR INTERNATIONAL CONFERENCE, 2014, 2014 (01): : 277 - 281
  • [3] MEASUREMENT OF ABSOLUTE RATE DATA FOR THE REACTION OF ATOMIC POTASSIUM, K(42S1/2), WITH CF3CL, CF2CL2, CFCL3, CF3BR AND SF6 AS A FUNCTION OF TEMPERATURE BY TIME-RESOLVED ATOMIC RESONANCE-ABSORPTION SPECTROSCOPY AT GAMMA = 404 NM [K(52PJ) ]- K(42S1/2)]
    HUSAIN, D
    LEE, YH
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS II, 1987, 83 : 2325 - 2337