A Simple Method for Validation and Verification of Pipettes Mounted on Automated Liquid Handlers

被引:16
|
作者
Stangegaard, Michael [1 ]
Hansen, Anders J. [1 ]
Froslev, Tobias G. [1 ]
Morling, Niels [1 ]
机构
[1] Univ Copenhagen, Sect Forens Genet, Dept Forens Med, Fac Hlth Sci, DK-2100 Copenhagen, Denmark
来源
JALA | 2011年 / 16卷 / 05期
关键词
CALIBRATION;
D O I
10.1016/j.jala.2009.06.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared in quadruplicates in a flat-bottom 96-well microtiter plate, manually using calibrated pipettes. Each pipette of the liquid handler (1-8) dispensed a selected volume (1-200 mu L) of OrangeG eight times into the wells of the microtiter plate. All wells contained a total of 200 mu L liquid. The absorbance was read, and the dispensed volume of each pipette was calculated based on a plot of volume and absorbance of a known set of OrangeG dilutions. Finally, the percent inaccuracy (%d) and the imprecision (%CV) of each pipette were calculated. Using predefined acceptance criteria, each pipette was then either approved or failed. Failed pipettes were either repaired or the volume deviation was compensated for by applying a calibration curve in the liquid-handler software. We have implemented the procedure on a Sias Xantus, an MWGt TheONYX, four Tecan Freedom EVO, a Biomek NX Span-8, and four Biomek 3000 robots, and the methods are freely available. In conclusion, we have set up a simple, inexpensive, and fast solution for the continuous validation of ALHs used for accredited work according to the ISO 17025 standard. The method is easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates. (JALA 2011;16:381-6)
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
  • [1] AUTOMATED LIQUID HANDLERS
    Rawat, Sachin
    [J]. Lab Manager, 2024, 19 (06):
  • [2] Simple method of drying pipettes
    Walker, VM
    [J]. JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1933, 19 : 324 - 324
  • [3] Optimization of automated liquid handlers
    Albert, Keith J.
    [J]. Albert, K.J., 1600, Mary Ann Liebert Inc. (33):
  • [4] Automated liquid handlers advance
    Brush, M
    [J]. SCIENTIST, 2002, 16 (03): : 38 - 41
  • [5] Piston-driven automated liquid handlers
    Schuster, Joachim
    Kamuju, Vinay
    Zhou, Jin
    Mathaes, Roman
    [J]. SLAS TECHNOLOGY, 2024, 29 (03):
  • [6] Importance of Integrating a Volume Verification Method for Liquid Handlers: Applications in Learning Performance Behavior
    Albert, Keith J.
    Bradshaw, John Thomas
    [J]. JALA - Journal of the Association for Laboratory Automation, 2007, 12 (03): : 172 - 180
  • [7] A simple method for determining the capacity of "to contain" pipettes
    Wheeler, MW
    [J]. JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1919, 4 : 498 - 501
  • [8] A simple method of cleaning capillary tubes and blood pipettes
    Pitt, GN
    [J]. LANCET, 1912, 2 : 1611 - 1611
  • [9] Minimizing Liquid Delivery risk: automated Liquid handlers as sources of error
    Technical Marketing Manager, ARTEL, 25 Bradley, Westbrook, ME 04092, United States
    [J]. Am Lab, 2007, 13 (8-10):
  • [10] Minimizing liquid delivery risk: Automated liquid handlers as sources of error
    Albert, Keith J.
    [J]. AMERICAN LABORATORY, 2007, 39 (13) : 8 - 10