Omnidirectional thermal anemometer for low airspeed and multi-point measurement applications

被引:8
|
作者
Gao, Yun [1 ,2 ,3 ]
Ramirez, Brett C. [1 ]
Hoff, Steven J. [1 ]
机构
[1] Iowa State Univ, Dept Agr & Biosyst Engn, 4332B Elings Hall, Ames, IA USA
[2] Huazhong Agr Univ, Coll Engn, Wuhan, Peoples R China
[3] Cooperat Innovat Ctr Sustainable Pig Prod, Wuhan, Peoples R China
关键词
Air velocity; Convection; Livestock; Poultry; Thermal environment; Uncertainty; HOT-WIRE; CALIBRATION;
D O I
10.1016/j.compag.2016.06.011
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Current control strategies for livestock and poultry facilities need to improve their interpretation of the Thermal Environment (TE) that the animals are experiencing in order to provide an optimum TE that is uniformly distributed throughout the facility; hence, airspeed, a critical parameter influencing evaporative and convective heat exchange must be measured. An omnidirectional, constant temperature, Thermal Anemometer (TA) with ambient dry-bulb temperature (tab) compensation was designed and developed for measuring airspeeds between 0 and 6.0 m s(-1). An Arduino measured two analog voltages to determine the thermistor temperature and subsequently the power being dissipated from a near spherical overheated thermistor in a bridge circuit with a transistor and operational amplifier. A custom wind tunnel featuring a 0.1 m diameter pipe with an access for TA insertion was constructed to calibrate the TA at different temperatures and airspeeds, at a constant relative humidity. The heat dissipation factor was calculated for a given airspeed at different ambient temperatures ranging from 18 degrees C to 34 degrees C and used in a unique fourth-order polynomial regression that compensates for temperature using the fluid properties evaluated at the film temperature. A detailed uncertainty analysis was performed on all key measurement inputs, such as the microcontroller analog to digital converter, TA and t(db) thermistor regression statistics, and the calibration standard, that were propagated through the calibration regression. Absolute combined standard uncertainty associated with temperature corrected airspeed measurements ranged from 0.11 m s(-1) (at 0.47 m s(-1); 30.3% relative) to 0.71 m s(-1) (at 5.52 m s-1; 12.8% relative). The TA system cost less than $35 USD in components and due to the simple hardware, this thermal anemometer is well-suited for integration into multi-point data acquisition systems analyzing spatial and temporal variability inside livestock and poultry housing. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:439 / 450
页数:12
相关论文
共 50 条
  • [1] Evaluation of a prototype thermal anemometer for use in low airspeed drying measure calculations
    Martin, DP
    Grant, JJ
    Ringwood, JV
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 12 (5-6) : 385 - 396
  • [2] Multi-point gap measurement by low coherence tandem interferometry
    Lu, Sheng-Hua
    Chang, Chi-Ying
    Kao, Ching-Fen
    [J]. INTERFEROMETRY XV: APPLICATIONS, 2010, 7791
  • [3] Multi-point methods for precision measurement
    Kiyono, Satoshi
    [J]. Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2010, 76 (02): : 165 - 168
  • [4] Applications of multi-point mirror supporting
    Zhuo Renshan
    Zhang Dongge
    [J]. SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS II, PTS 1 AND 2, 2014, 475-476 : 1555 - +
  • [5] Simultaneous multi-point LDV measurement system
    College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
    [J]. Guangdianzi Jiguang, 2007, 7 (824-827):
  • [6] Multi-point mobile measurement of atmospheric transmittance
    Tai, Hong-Da
    Zhuang, Zi-Bo
    Jiang, Li-Hui
    Sun, Dong-Song
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2016, 24 (08): : 1894 - 1901
  • [7] A Multi-Point Measurement Method for Thermal Characterization of Foil Bearings Using Customized Thermocouples
    Lubieniecki, Michal
    Roemer, Jakub
    Martowicz, Adam
    Wojciechowski, Krzysztof
    Uhl, Tadeusz
    [J]. JOURNAL OF ELECTRONIC MATERIALS, 2016, 45 (03) : 1473 - 1477
  • [8] A Multi-Point Measurement Method for Thermal Characterization of Foil Bearings Using Customized Thermocouples
    Michał Lubieniecki
    Jakub Roemer
    Adam Martowicz
    Krzysztof Wojciechowski
    Tadeusz Uhl
    [J]. Journal of Electronic Materials, 2016, 45 : 1473 - 1477
  • [9] Multi-point sensing system for plantar pressure measurement
    Venugopal, G.
    Parmar, Biren J.
    Rajanna, K.
    Nayak, M. M.
    [J]. 2007 IEEE SENSORS, VOLS 1-3, 2007, : 978 - 981
  • [10] FLATNESS MEASUREMENT BY MULTI-POINT METHODS AND BY SCANNING METHODS
    Lakota, Stanislav
    Goeroeg, Augustin
    [J]. AD ALTA-JOURNAL OF INTERDISCIPLINARY RESEARCH, 2011, 1 (01): : 124 - 127