Saliva analysis by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF/MS): from sample collection to data analysis

被引:26
|
作者
Papale, Massimo [1 ]
Pedicillo, Maria Carmela [2 ]
Di Paolo, Salvatore [3 ]
Thatcher, Bradley John [4 ]
Lo Muzio, Lorenzo [2 ]
Bufo, Pantaleo [2 ]
Rocchetti, Teresa [1 ]
Centra, Marta [5 ]
Ranieri, Elena [5 ]
Gesualdo, Loreto [1 ]
机构
[1] Univ Foggia, Nephrol Sect, Dept Biomed Sci & Bioagromed, Fac Med,Mol Med Ctr, I-71100 Foggia, Italy
[2] Univ Foggia, Fac Med, Dept Surg Sci, I-71100 Foggia, Italy
[3] Hosp Dimiccoli, Div Nephrol & Dialysis, Barletta, Italy
[4] Ciphergen Biosyst, Fremont, CA USA
[5] Univ Foggia, Sect Clin Pathol, Dept Biomed Sci, Foggia, Italy
关键词
saliva; sample collection; surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF/MS); standardization;
D O I
10.1515/CCLM.2008.013
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Saliva is one of the most promising and easy-to-collect source of potential biomarkers of oral and systemic disease. We standardized a protocol suitable for pre-analytical treatment and for the analysis of whole normal saliva by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF/MS). Methods: We evaluated the impact of storage time, freeze/thaw cycles, denaturing agents, glycoproteins depletion, centrifugation, type of matrix and ProteinChip((R)) used on the quality of the SELDI protein profile. Moreover, we explored the inter-individual and between-sex differences and the changes in the sample composition over the day. Results: Saliva was qualitatively stable, in the absence of protease inhibitors, for up to 3 h from the collection at room temperature, although the intensity of a number of peaks slightly decreased between 0 and 3 h and the addition of protease inhibitors did not completely revert this trend. The saliva proteome changed during the day and showed relevant between-sex differences. The protein profile remained stable for up to five freeze/thaw cycles. The addition of denaturing solutions and the depletion of glycoproteins improved the quality of the spectra without affecting their reproducibility. Conclusions: We defined a protocol that improved the quality and the reproducibility of SELDI-TOF/MS analysis, thus potentially supporting the search for putative biomarkers of disease.
引用
收藏
页码:89 / 99
页数:11
相关论文
共 50 条
  • [1] Surface-enhanced laser desorption ionization/time-of-flight (SELDI-TOF) mass spectrometry (MS) as a phenotypic method for rapid identification of antibiotic resistance
    Dubska, Lenka
    Pilatova, Katerina
    Dolejska, Monika
    Bortlicek, Zbynek
    Frostova, Tereza
    Literak, Ivan
    Valik, Dalibor
    ANAEROBE, 2011, 17 (06) : 444 - 447
  • [2] DISCOVERY OF POTENTIAL PLASMA BIOMARKERS OF CHOLANGIOCARCINOMA UTILISING SURFACE-ENHANCED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS SPECTROMETRY (SELDI-TOF MS)
    Wadsworth, C. A.
    Horneffer-van der Sluis, V. M.
    Zabron, A.
    Taylor-Robinson, S. D.
    Edwards, R. J.
    Khan, S. A.
    GUT, 2013, 62 : A86 - A86
  • [3] Applications of Surface-Enhanced Laser Desorption/Ionization Time-Of-Flight (SELDI-TOF) Mass Spectrometry in Defining Salivary Proteomic Profiles
    Al-Tarawneh, Sandra K.
    Bencharit, Sompop
    OPEN DENTISTRY JOURNAL, 2009, 3 : 74 - 79
  • [4] Protein detection in dried blood by surface-enhanced laser desorption/ionization-time of flight mass spectrometry (SELDI-TOF MS)
    Dammann, CEL
    Meyer, M
    Dammann, O
    von Neuhoff, N
    BIOLOGY OF THE NEONATE, 2006, 89 (02): : 126 - 132
  • [5] Muscle protein expression profiling by surface enhanced laser desorption ionization time-of-flight (SELDI-TOF) mass spectrometry
    Flanigan, KM
    Cannon, J
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2002, 199 : S73 - S73
  • [6] Influence of sample storage duration on serum protein profiles assessed by surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF MS)
    Gast, Marie-Christine W.
    van Gils, Carla H.
    Wessels, Lodewijk F. A.
    Harris, Nathan
    Bonfrer, Johannes M. G.
    Rutgers, Emiel J. Th.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (06) : 694 - 705
  • [7] Surface-enhanced laser desorption ionization time-of-flight mass spectrometry (SELDI TOF-MS) and ProteinChip® technology in proteomics research
    Seibert, V
    Wiesner, A
    Buschmann, T
    Meuer, J
    PATHOLOGY RESEARCH AND PRACTICE, 2004, 200 (02) : 83 - 94
  • [8] Optimization and evaluation of surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) with reversed-phase protein arrays for protein profiling
    Aivado, M
    Spentzos, D
    Alterovitz, G
    Otu, HH
    Grall, F
    Giagounidis, AAN
    Wells, M
    Cho, JY
    Germing, U
    Czibere, A
    Prall, WC
    Porter, C
    Ramoni, MF
    Libermann, TA
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (02) : 133 - 140
  • [9] Identification of putative serum markers of pancreatic adenocarcinoma using surface enhanced laser desorption ionization time-of-flight mass spectrometry (SELDI-TOF MS)
    Scarlett, Christopher J.
    Baxter, Robert C.
    Smith, Ross C.
    CANCER RESEARCH, 2006, 66 (08)
  • [10] Quality control and quality assessment of data from surface-enhanced laser desorption/ionization (SELDI) time-of flight (TOF) mass spectrometry (MS)
    Hong, HX
    Dragan, Y
    Epstein, J
    Teitel, C
    Chen, BZ
    Xie, Q
    Fang, H
    Shi, LM
    Perkins, R
    Tong, WD
    BMC BIOINFORMATICS, 2005, 6 (Suppl 2)