Three-dimensional registration of magnetic resonance image data to histological sections with model-based evaluation

被引:35
|
作者
Breen, MS
Lazebnik, RS
Wilson, DL
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH USA
[3] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
关键词
image registration; histology; tissue typing with medical images; interventional magnetic resonance imaging (iMRI);
D O I
10.1007/s10439-005-5778-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a three-dimensional (3D) registration method to align medical scanner data with histological sections. After acquiring 3D medical scanner images, we sliced and photographed the tissue using, a custom apparatus, to obtain a volume of tissue section images. Histological samples from the sections were digitized using a video microscopy system. We aligned the histology and medical images to the reference tissue images using our 3D registration method. We applied the method to correlate in vivo magnetic resonance (MR) and histological measurements for radio-frequency thermal ablation lesions in rabbit thighs. For registration evaluation, we used an ellipsoid model to describe the lesion surfaces. The model surface closely fit the inner (M1) and outer (M2) boundaries of the hyperintense region in MR lesion images, and the boundary of necrosis (H1) in registered histology images. We used the distance between the model surfaces to indicate the 3D registration error. For four experiments, we measured a registration accuracy of 0.96 +/- 0.13 mm (mean +/- SD) from the absolute distance between the M2 and H1 model surfaces, which compares favorably to the 0.70 mm in-plane MR voxel dimension. This suggests that our registration method provides sufficient spatial correspondence to correlate 3D medical scanner and histology data.
引用
收藏
页码:1100 / 1112
页数:13
相关论文
共 50 条
  • [1] Three-Dimensional Registration of Magnetic Resonance Image Data to Histological Sections with Model-Based Evaluation
    Michael S. Breen
    Roee S. Lazebnik
    David L. Wilson
    [J]. Annals of Biomedical Engineering, 2005, 33 : 1100 - 1112
  • [2] Registration of three-dimensional scanning LiDAR sensors: An evaluation of model-based and model-free methods
    D'Adamo, Timothy Andrew
    Phillips, Tyson Govan
    McAree, Peter Ross
    [J]. JOURNAL OF FIELD ROBOTICS, 2018, 35 (07) : 1182 - 1200
  • [3] Application of three-dimensional magnetic resonance image registration for monitoring hip joint diseases
    Takao, M
    Sugano, N
    Nishii, T
    Tanaka, H
    Masumoto, J
    Miki, H
    Sato, Y
    Tamura, S
    Yoshikawa, H
    [J]. MAGNETIC RESONANCE IMAGING, 2005, 23 (05) : 665 - 670
  • [4] Registration and warping of magnetic resonance images to histological sections
    Jacobs, MA
    Windham, JP
    Soltanian-Zadeh, H
    Peck, DJ
    Knight, RA
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1568 - 1578
  • [5] Three-dimensional Elastic Image Registration Based on Strain Energy Minimization: Application to Prostate Magnetic Resonance Imaging
    Zhang, Bao
    Arola, Dwayne D.
    Roys, Steve
    Gullapalli, Rao P.
    [J]. JOURNAL OF DIGITAL IMAGING, 2011, 24 (04) : 573 - 585
  • [6] Three-dimensional Elastic Image Registration Based on Strain Energy Minimization: Application to Prostate Magnetic Resonance Imaging
    Bao Zhang
    Dwayne D. Arola
    Steve Roys
    Rao P. Gullapalli
    [J]. Journal of Digital Imaging, 2011, 24 : 573 - 585
  • [7] Registration of three-dimensional magnetic resonance and radionuclide skeletal images
    Wong, TZ
    Connolly, LP
    Treves, ST
    [J]. CLINICAL NUCLEAR MEDICINE, 1999, 24 (11) : 859 - 863
  • [8] Performance evaluation of a newly developed three-dimensional model-based global-to-local registration in prostate cancer
    Nakamura, Mitsuhiro
    Nakao, Megumi
    Hirashima, Hideaki
    Iramina, Hiraku
    Mizowaki, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2019, 60 (05) : 595 - 602
  • [9] Elastic registration of x-ray mammograms and three-dimensional magnetic resonance imaging data
    N. V. Ruiter
    T. O. Müller
    R. Stotzka
    W. A. Kaiser
    [J]. Journal of Digital Imaging, 2001, 14 : 52 - 55
  • [10] Elastic registration of x-ray mammograms and three-dimensional magnetic resonance imaging data
    Ruiter, NV
    Müller, TO
    Stotzka, R
    Kaiser, WA
    [J]. JOURNAL OF DIGITAL IMAGING, 2001, 14 (02) : 52 - 55