Transient Analysis of Buried Cables Considering a Nodal Admittance Matrix Approach

被引:2
|
作者
Duarte, Naiara [1 ]
De Conti, Alberto [2 ]
Alipio, Rafael [3 ]
机构
[1] Univ Fed Minas Gerais, PPGEE UFMG, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, LRC DEE UFMG, Belo Horizonte, MG, Brazil
[3] Fed Ctr Technol Educ, DEE CEFET MG, Belo Horizonte, MG, Brazil
关键词
transmission line theory; ground return impedance; ground admittance; frequency dependence of soil electrical parameters; buried cables; transient analysis; RATIONAL APPROXIMATION; IMPEDANCE;
D O I
10.1109/sipda47030.2019.8951532
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the transient behavior of buried bare and insulated cables is analyzed using transmission line (TL) theory. The proposed approach is based on a passive pole-residue model of the nodal admittance matrix, which can be represented as an electrical network suitable to time-domain simulations in electromagnetic transients programs. The influence of a finitely conducting soil is computed by means of Sunde's ground return impedance equation. An approximate expression is considered to represent the ground admittance. Furthermore, the frequency dependence of the electrical parameters of the soil is considered. The proposed methodology is validated by comparing the results it provides with those obtained by a popular electromagnetic transient program and a field theory approach. The results show that ignoring the ground admittance and the frequency dependence of soil parameters can lead to inaccuracies in transient studies involving buried cables, especially in the case of high-resistivity soils and transients with a wide frequency range.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Modelling seabed buried cables for electromagnetic transient analysis
    Leao Veloso Silva, Jose Carlos
    Siqueira Lima, Antonio Carlos
    Cardillo Magalhaes, Antonio Paulo
    Correia de Barros, Maria Teresa
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (06) : 1575 - 1582
  • [2] TRANSIENT HEATING OF BURIED POWER CABLES
    GOLDENBERG, H
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1967, 114 (06): : 809 - +
  • [3] TRANSIENT ANALYSIS OF COAXIAL CABLES CONSIDERING SKIN EFFECT
    WIGINGTON, RL
    NAHMAN, NS
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1957, 45 (02): : 166 - 174
  • [4] An Approach for Nodal Admittance Matrix Real-Time Estimation on DC Microgrids
    Garces, Alejandro
    Rodriguez-Garcia, Luis
    2019 IEEE GREEN TECHNOLOGIES CONFERENCE (GREENTECH), 2019,
  • [5] On the Properties of the Power Systems Nodal Admittance Matrix
    Kettner, Andreas Martin
    Paolone, Mario
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (01) : 1130 - 1131
  • [6] SPARSITY OF NODAL ADMITTANCE MATRIX AND ITS APPLICATIONS
    SHINODA, S
    KAJITANI, Y
    ELECTRONICS & COMMUNICATIONS IN JAPAN, 1973, 56 (09): : 74 - 81
  • [7] Transient Rating of Buried Cables: a Comparative Study
    Le Roux, B. J.
    Walker, J. J.
    2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [8] Reduced Nodal Admittance Matrix Method for Probabilistic GIC Analysis in Power Grids
    Liu, Min-zhou
    Xie, Yan-zhao
    Yang, Yi-fan
    Trinchero, Riccardo
    Stievano, Igor S.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2023, 38 (05) : 4950 - 4953
  • [9] On Eigenvalues of the Three-Phase Nodal Admittance Matrix
    Casolino, Giovanni M.
    Losi, Arturo
    2019 AEIT INTERNATIONAL ANNUAL CONFERENCE (AEIT), 111TH EDITION, 2019,
  • [10] INVERSION OF NODAL-ADMITTANCE MATRIX IN SYMBOLIC FORM
    DOWNS, T
    ELECTRONICS LETTERS, 1970, 6 (03) : 74 - &