Adaptation of dual energy X-ray absorptiometry (DXA) in the veterinary medicine. Literature review

被引:0
|
作者
Toth Peter [1 ]
Horvath Csaba
Ferencz Viktoria
Szenci Otto [1 ]
Bodo Gabor [2 ]
机构
[1] SZIE AOTK, Nagyallatklin Dora Major, H-2225 Ullo, Hungary
[2] Univ Bern, Dept Klin, Dept Klin Vet Med, Tierspital Pferdeklin, CH-3012 Bern, Switzerland
关键词
BONE-MINERAL DENSITY; EQUINE 3RD METACARPAL; PRECISION; ACCURACY; GROWTH;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Dual energy X-ray absorptiometry (DXA) is a widespread method to assess bone mineral density (BMD) and bone mineral content (BMC) in human practice, and adaptation of its use in veterinary medicine has also started. Bone densitometry is the current method for the diagnosis of human calcipenic osteopathy. The authors briefly summarize the evolution and development of densitometry in small (rat, rabbit, cat and dog) and large (pig, sheep and horse) animals.
引用
收藏
页码:562 / 569
页数:8
相关论文
共 50 条
  • [1] A review of the use of dual-energy X-ray absorptiometry (DXA) in rheumatology
    Tanner, S. Bobo
    Moore, Charles F., Jr.
    OPEN ACCESS RHEUMATOLOGY-RESEARCH AND REVIEWS, 2012, 4 : 99 - 107
  • [2] Dual Energy X-ray Absorptiometry (DXA) in the Management of Osteoporosis
    Zaman, Maseeh uz
    Fatima, Nosheen
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2024, 34 (06): : 633 - 635
  • [3] Body composition measured by dual energy X-ray absorptiometry (DXA).
    Boileau, R
    Slaughter, M
    Stillman, R
    Christ, G
    Dykstra, R
    Geeseman, R
    FarrellLee, K
    Novitsky, S
    Pritschet, B
    FASEB JOURNAL, 1996, 10 (03): : 1119 - 1119
  • [4] Absorbed dose measurements in dual energy X-ray absorptiometry (DXA)
    Bezakova, E
    Collins, PJ
    Beddoe, AH
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 172 - 179
  • [5] Movement artifact and dual x-ray absorptiometry (DXA).
    Cawkwell, GD
    ARTHRITIS AND RHEUMATISM, 1996, 39 (09): : 368 - 368
  • [6] Dual Energy X-Ray Absorptiometry (DXA) Transmission Methodology in Clinical Trials
    Colin G. Miller
    Anthony A. Lyons
    David W. Pye
    Mandy Blaze
    Grace A. Fasano
    Simone Horneye
    Drug information journal : DIJ / Drug Information Association, 1998, 32 (4): : 1165 - 1168
  • [7] X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)
    Kim, Kwang Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2155 - 2158
  • [8] Use of Dual Energy X-ray Absorptiometry (DXA) in Paleopathology for the Study of Osteoporosis
    Albuquerque, A.
    Curate, F.
    Correia, J.
    Ferreira, I.
    Costa, G.
    Pedroso de Lima, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S215 - S215
  • [9] Dual energy X-ray absorptiometry (DXA) transmission methodology in clinical trials
    Miller, CG
    Lyons, AA
    Pye, DW
    Blaze, M
    Fasano, GA
    Horneye, S
    DRUG INFORMATION JOURNAL, 1998, 32 (04): : 1165 - 1168
  • [10] Updated practice guideline for dual-energy X-ray absorptiometry (DXA)
    Slart, Riemer H. J. A.
    Punda, Marija
    Ali, Dalal S.
    Bazzocchi, Alberto
    Bock, Oliver
    Camacho, Pauline
    Carey, John J.
    Colquhoun, Anita
    Compston, Juliet
    Engelke, Klaus
    Erba, Paola A.
    Harvey, Nicholas C.
    Krueger, Diane
    Lems, Willem F.
    Lewiecki, E. Michael
    Morgan, Sarah
    Moseley, Kendall F.
    O'Brien, Christopher
    Probyn, Linda
    Rhee, Yumie
    Richmond, Bradford
    Schousboe, John T.
    Shuhart, Christopher
    Ward, Kate A.
    van den Wyngaert, Tim
    Zhang-Yin, Jules
    Khan, Aliya A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, : 539 - 563