A comparison of optimization algorithms for localized in vivo B0 shimming

被引:16
|
作者
Nassirpour, Sahar [1 ,2 ]
Chang, Paul [1 ,2 ]
Fillmer, Ariane [5 ]
Henning, Anke [1 ,3 ,4 ]
机构
[1] Max Planck Inst Biol Cybernet, Spemannstr 41, D-72076 Tubingen, Germany
[2] Eberhard Karls Univ Tuebingen, IMPRS Cognit & Syst Neurosci, Tubingen, Germany
[3] UZH, Inst Biomed Engn, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Zurich, Switzerland
[5] Phys Tech Bundesanstalt, Berlin, Germany
基金
欧盟地平线“2020”;
关键词
B-0; shimming; ultrahigh field strengths; constrained regularization; single-voxel; constrained optimization; HUMAN BRAIN; FIELD; REGION;
D O I
10.1002/mrm.26758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo compare several different optimization algorithms currently used for localized in vivo B-0 shimming, and to introduce a novel, fast, and robust constrained regularized algorithm (ConsTru) for this purpose. MethodsTen different optimization algorithms (including samples from both generic and dedicated least-squares solvers, and a novel constrained regularized inversion method) were implemented and compared for shimming in five different shimming volumes on 66 in vivo data sets from both 7T and 9.4T. The best algorithm was chosen to perform single-voxel spectroscopy at 9.4T in the frontal cortex of the brain on 10 volunteers. ResultsThe results of the performance tests proved that the shimming algorithm is prone to unstable solutions if it depends on the value of a starting point, and is not regularized to handle ill-conditioned problems. The ConsTru algorithm proved to be the most robust, fast, and efficient algorithm among all of the chosen algorithms. It enabled acquisition of spectra of reproducible high quality in the frontal cortex at 9.4T. ConclusionsFor localized in vivo B-0 shimming, the use of a dedicated linear least-squares solver instead of a generic nonlinear one is highly recommended. Among all of the linear solvers, the constrained regularized method (ConsTru) was found to be both fast and most robust. Magn Reson Med 79:1145-1156, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:1145 / 1156
页数:12
相关论文
共 50 条
  • [1] In vivo B0 field shimming methods for MRI at 7 T
    Stockmann, Jason P.
    Wald, Lawrence L.
    NEUROIMAGE, 2018, 168 : 71 - 87
  • [2] On the impact of B0 shimming algorithms on single-voxel MR spectroscopy
    Afkham, Behrouz Vejdani
    Alonso-Ortiz, Eva
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (01) : 42 - 50
  • [3] AUTOMATED SHIMMING OF B0 FOR SPECTROSCOPIC IMAGING
    TROPP, J
    DERBY, KA
    HAWRYSZKO, C
    SUGIURA, S
    YAMAGATA, H
    JOURNAL OF MAGNETIC RESONANCE, 1989, 85 (02): : 244 - 254
  • [4] B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy
    Juchem, Christoph
    de Graaf, Robin A.
    ANALYTICAL BIOCHEMISTRY, 2017, 529 : 17 - 29
  • [5] Dynamic B0 shimming at 7 T
    Sengupta, Saikat
    Welch, E. Brian
    Zhao, Yansong
    Foxall, David
    Starewicz, Piotr
    Anderson, Adam W.
    Gore, John C.
    Avison, Malcolm J.
    MAGNETIC RESONANCE IMAGING, 2011, 29 (04) : 483 - 496
  • [6] Localized B0 shimming based on 23Na MRI at 7 T
    Gast, Lena, V
    Henning, Anke
    Hensel, Bernhard
    Uder, Michael
    Nagel, Armin M.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) : 1339 - 1347
  • [7] Integrated RF/shim coil array for parallel reception and localized B0 shimming in the human brain
    Trong-Kha Truong
    Darnell, Dean
    Song, Allen W.
    NEUROIMAGE, 2014, 103 : 235 - 240
  • [8] Flexible multi-purpose integrated RF/shim coil array for MRI and localized B0 shimming
    Overson, Devon Karl
    Darnell, Dean
    Robb, Fraser
    Song, Allen W.
    Trong-Kha Truong
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 842 - 849
  • [9] Shimming toolbox: An open-source software toolbox for B0 and B1 shimming in MRI
    D'Astous, Alexandre
    Cereza, Gaspard
    Papp, Daniel
    Gilbert, Kyle M.
    Stockmann, Jason P.
    Alonso-Ortiz, Eva
    Cohen-Adad, Julien
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1401 - 1417
  • [10] An iPRES-W Coil Array for Simultaneous Imaging and Wireless Localized B0 Shimming of the Cervical Spinal Cord
    Cuthbertson, Jonathan D.
    Trong-Kha Truong
    Stormont, Robert
    Robb, Fraser
    Song, Allen W.
    Darnell, Dean
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) : 1002 - 1014