Automated detection of malaria pigment in white blood cells for the diagnosis of malaria in Portugal

被引:0
|
作者
Hänscheid, T [1 ]
Melo-Cristino, J [1 ]
Pinto, BG [1 ]
机构
[1] Hosp Santa Maria, Dept Clin Pathol, P-1600 Lisbon, Portugal
来源
关键词
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A novel automated method (Cell-Dyn(R) 3500) allows malaria diagnosis by detecting malaria pigment in white blood cells during routine full blood counts. In Portugal, 174 samples from 148 patients who presented to the emergency department were analyzed. Compared with microscopy the sensitivity was 95% and the specificity was 88%. In 5 cases, false-positive Cell-Dyn(R) 3500 results were from patients who had a recent history of treated malaria, indicating that the method may remain positive during convalescence. Six patients were diagnosed due to the changes observed with the automated method only, because clinicians had not requested malaria smears. This instrument appears to provide a promising method for the diagnosis of malaria, especially where automated full blood counts are routine in the work-up of febrile patients.
引用
收藏
页码:290 / 292
页数:3
相关论文
共 50 条
  • [1] Automated malaria diagnosis using pigment detection
    Hänscheid, T
    Valadas, E
    Grobusch, MP
    PARASITOLOGY TODAY, 2000, 16 (12): : 549 - 551
  • [2] Automated detection of malaria pigment: feasibility for malaria diagnosing in an area with seasonal malaria in northern Namibia
    de Langen, Adrianus J.
    van Dillen, Jeroen
    de Witte, Piet
    Mucheto, Samson
    Nagelkerke, Nico
    Kager, Piet
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2006, 11 (06) : 809 - 816
  • [3] Parasite detection and identification for automated thin blood film malaria diagnosis
    Tek, F. Boray
    Dempster, Andrew G.
    Kale, Izzet
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2010, 114 (01) : 21 - 32
  • [4] Analysis of Thin Blood Images for Automated Malaria Diagnosis
    Reni, Saumya Kareem
    Kale, Izzet
    Morling, Richard
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [5] Automated malaria detection
    Hänscheid, T
    Valadas, E
    BRITISH JOURNAL OF HAEMATOLOGY, 1999, 106 (01) : 257 - 257
  • [6] Toward Development of Automated Plasmodium Detection for Malaria Diagnosis in Thin Blood Smear Image: an Overview
    Saputra, Wahyu Andi
    Nugroho, Hanung Adi
    Permanasari, Adhistya Erna
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY SYSTEMS AND INNOVATION (ICITSI), 2016,
  • [7] Automated Malaria Parasite and there Stage Detection in Microscopic Blood Images
    Charpe, Kshipra C.
    Bairagi, V. K.
    PROCEEDINGS OF 2015 IEEE 9TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND CONTROL (ISCO), 2015,
  • [8] A review on automated diagnosis of malaria parasite in microscopic blood smears images
    Zahoor Jan
    Arshad Khan
    Muhammad Sajjad
    Khan Muhammad
    Seungmin Rho
    Irfan Mehmood
    Multimedia Tools and Applications, 2018, 77 : 9801 - 9826
  • [9] A review on automated diagnosis of malaria parasite in microscopic blood smears images
    Jan, Zahoor
    Khan, Arshad
    Sajjad, Muhammad
    Muhammad, Khan
    Rho, Seungmin
    Mehmood, Irfan
    MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (08) : 9801 - 9826
  • [10] An automated malaria cells detection from thin blood smear images using deep learning
    Sukumarran, D.
    Hasikin, K.
    Khairuddin, Mohd
    Ngui, R.
    Sulaiman, Wan
    Vythilingam, I.
    Divis, P. C. S.
    TROPICAL BIOMEDICINE, 2023, 40 (02) : 208 - 219